This manual confers no industrial property rights or any rights of any other kind,
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be
held responsible for any problems involving industrial property rights which may
occur as a result of using the contents noted in this manual.
Warranty
Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:
(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.
(3) Special damages and secondary damages whether foreseeable or not, compensation for
accidents, and compensation for damages to products other than Mitsubishi products.
(4) Replacement by the user, maintenance of on-site equipment, start-up test run
and other tasks.
For safe use
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Side
A
Side
B
JAPANESE
ENGLISH
JY997D66701A
Side
B
Safety Precaution
(Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and
.
Depending on the circumstances, procedures indicated by
may also
cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manuals
How to obtain manuals
For the necessary product manuals or documents, consult with your local
Mitsubishi Electric representative.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in minor or moderate injury or
property damage.
Manual name
Manual No.
Description
MELSEC iQ-F
FX5 User's Manual
(Analog Control)
JY997D60501 Explains analog control.
MELSEC iQ-F
FX5U User's Manual
(Hardware)
JY997D55301
Explains FX5U PLC specification
details for I/O, wiring, installation, and
maintenance.
MELSEC iQ-F
FX5UC User's Manual
(Hardware)
JY997D61301
Explains FX5UC PLC specification
details for I/O, wiring, installation, and
maintenance.
Applicable standards
FX5-4AD-TC-ADP comply with the EC Directive (EMC Directive) and UL standards
(UL, cUL). Further information can be found in the following manual.
MELSEC iQ-F FX5U User's Manual (Hardware)
MELSEC iQ-F FX5UC User's Manual (Hardware)
Regarding the standards that relate to the CPU module, please refer to either the
product catalog or consult with your nearest Mitsubishi product provider.
Attention
This product is designed for use in industrial applications.
Caution for EC Directive
Installation in Enclosure
Programmable controllers are open-type devices that must be installed and used
within conductive control cabinets. Please use the programmable controller while
installed within a conductive shielded control cabinet. Installation within a control
cabinet greatly affects the safety of the system and aids in shielding noise from the
programmable controller.
Control cabinet
- The control cabinet must be conductive.
- Ground the control cabinet with the thickest possible grounding cable.
- To ensure that there is electric contact between the control cabinet and its door,
connect the cabinet and its doors with thick wires.
- In order to suppress the leakage of radio waves, the control cabinet structure
must have minimal openings. Also, wrap the cable holes with a shielding cover or
other shielding devices.
- The gap between the control cabinet and its door must be as small as possible by
attaching EMI gaskets between them.
*1 These wires are used to improve the conductivity between the door and control
cabinet.
Cables
- Make sure to use shielded cables as cables pulled out of the control cabinet.
- Connect the shield such as shielded cables and shielding covers to the grounded
control cabinet.
It is possible that the accuracy temporarily fluctuates within ±10 %.
1. Outline
FX5-4AD-TC-ADP expansion adapter for thermocouple temperature sensor input
(hereinafter called TC-ADP) is an expansion adapter for connecting a thermocouple (K,
J, T, B, R, S) temperature sensor, and measuring 4 channels of temperature.
1.1 Incorporated Items
Verify that the following product and items are included in the package:
Product
FX5-4AD-TC-ADP thermocouple temperature sensor input
expansion adapter
Included Items
Hardware manual (This manual)
Shielding cover
Shielded cable
Wires
*1
EMI gasket
1.2 External Dimensions, Part Names, and Terminal Layout
2. Installation
To use two or more FX5-4DA-ADP, connect them to only one side of this product. Do
not connect them to both sides.
For the installation, refer to the following manual.
MELSEC iQ-F FX5U User's Manual (Hardware)
MELSEC iQ-F FX5UC User's Manual (Hardware)
[1] DIN rail mounting groove (DIN rail: DIN46277, 35 mm wide)
[2] Name plate
[3] Expansion adapter slide lock
[4] Expansion adapter connector cover
[5] Direct mounting hole: 2 holes of
4.5 (mounting screw: M4 screw)
[6] PWR LED (green)
[7] Terminal block (European type terminal block)
[8] Expansion adapter connector
[9] DIN rail mounting hook
[10] Expansion adapter fixing hook
[11] Expansion adapter connector
INSTALLATION
PRECAUTIONS
Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
Use the product within the generic environment specifications described in the
User's Manual (Hardware) for the CPU module to be used.
Never use the product in areas with excessive dust, oily smoke, conductive dusts,
corrosive gas (salt air, Cl
2
, H
2
S, SO
2
or NO
2
), flammable gas, vibration or
impacts, or expose it to high temperature, condensation, or rain and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.
INSTALLATION
PRECAUTIONS
Do not touch the conductive parts of the product directly.
Doing so may cause device failures or malfunctions.
When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
Install the product on a flat surface.
If the mounting surface is rough, undue force will be applied to the PC board,
thereby causing nonconformities.
Install the product securely using a DIN rail or mounting screws.
Connect the expansion board and expansion adapter securely to their designated
connectors.
Loose connections may cause malfunctions.
8
74
15.1
90
98 (mounting hole pitch)
106
17.6
15.1
[6]
[5]
[10]
Unit: mm
Terminal
layout
[7]
[8]
[9]
[3]
[2]
[4]
[1]
L1+
L1-
L3+
L3-
L2+
L2-
L4+
L4-
Weight: Approx. 0.1 kg
Outer painting color: Munsell 0.6B7.6/0.2
Special adapter
connector cover is
removed
[11]
•
•
•
•
•
3. Wiring
3.1 Cable End Treatment And Tightening Torque
3.1.1
European type terminal block
1) Wiring type
Use shielded compensating lead wire that is suitable for the thermocouple
type when wiring the thermocouple.
2) Suitable wiring
3) Tightening torque
Tighten the terminal screws with 0.20 N
m.
Do not tighten the screws outside the specified torque.
Failure to do so may cause equipment failures or malfunctions.
4) Wire end treatment
Strip the coating of strand wire and twist the cable core before connecting it,
or strip the coating of single wire before connecting it.
When using a wire ferrule with an insulating sleeve, choose a wire with
proper cable sheath referring to the above outside dimensions, otherwise
the wire cannot be inserted easily.
<Reference>
WIRING PRECAUTIONS
Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
Make sure to properly wire to the terminal block (European type) in
accordance with the following precautions.
Failure to do so may cause electric shock, equipment failures, a short-circuit,
wire breakage, malfunctions, or damage to the product.
- The disposal size of the cable end should follow the dimensions described
in the manual.
- Tightening torque should follow the specifications in the manual.
- Twist the ends of stranded wires and make sure that there are no loose
wires.
- Do not solder-plate the electric wire ends.
- Do not connect more than the specified number of wires or electric wires
of unspecified size.
- Affix the electric wires so that neither the terminal block nor the connected
parts are directly stressed.
WIRING PRECAUTIONS
When drilling screw holes or wiring, make sure cutting or wire debris does
not enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
Make sure to observe the following precautions in order to prevent any
damage to the machinery or accidents due to malfunction of the PLC caused
by abnormal data written to the PLC due to the effects of noise:
1) Do not bundle the power line or analog input/output cable together with or
lay them close to the main circuit, high-voltage line, load line or power
line. As a guideline, lay the power line, control line and communication
cables at least 100 mm away from the main circuit, high-voltage line, load
line or power line.
2) Ground the shield of the analog input/output cable at one point on the
signal receiving side.
However, do not use common grounding with heavy electrical systems.
No. of wire
per terminal
Wire size
Single wire, Strand wire Ferrules with insulating sleeve
One wire
AWG22 to 20
(0.3 to 0.5 mm
2
)
AWG22 to 20
(0.3 to 0.5 mm
2
)
Two wires
AWG22 (0.3 mm
2
)
-
Manufacturer
Model
Caulking tool
Phoenix Contact GmbH & Co. KG
AI 0.5-8 WH
CRIMPFOX 6
CRIMPFOX 6T-F
8 mm
Contact area
(Crimp area)
14 mm
2.6 mm
Insulation sleeve
- Stick terminal with insulating sleeve
9 mm
- Strand wire/single wire
5) Tool
For tightening the terminal, use a
c o m m e r c i a l l y a v a i l a b l e s m a l l
screwdriver having a straight form
that is not widened toward the end
as shown right.
Note:
If the diameter of screwdriver grip is too small, tightening torque may not be
achieved. To achieve the appropriate tightening torque shown in the table
above, use the following screwdriver or appropriate replacement (grip
diameter: approximately 25 mm (0.98")).
6) Terminal block fixed screw tightening torque
Tighten the screws within the range of 0.2 to 0.3 N
m.
Do not tighten terminal screws exceeding with a torque outside the
abovementioned range.
Failure to do so may cause equipment failures or malfunctions.
3.2 Wiring of Thermocouple
For the terminal configuration, refer to Section 1.2
3.2.1
Selection of the thermocouple
Thermocouple type
- There are 6 types of thermocouples: K ,J, T, B, R, and S type.
- Use insulated thermocouple types.
Compensating lead wire
- When the thermocouple is extended, use compensating lead wire that is
suitable for the type.
- The influence of wiring resistance of thermocouple and compensating lead
wire is approximately -0.083
V/
..
3.2.2
Example of thermocouple wiring
3.2.3
Precautions on thermocouple wiring
Separate the cable of the resistance thermometer detector from other power
cables or areas easily affected by inductive noise (from commercial power,
etc.).
3.3 Grounding
Grounding should be performed as stated below.
The grounding resistance should be 100
or less.
Independent grounding should be performed for best results.
When independent grounding is not performed, perform "shared grounding" of
the following figure.
For the details, refer to the following manual.
MELSEC iQ-F FX5U User's Manual (Hardware)
MELSEC iQ-F FX5UC User's Manual (Hardware)
The grounding wire size should be AWG 22 to 20 (0.3 to 0.5 mm
2
).
The grounding point should be close to the PLC, and all grounding wire should
be as short as possible.
Manufacturer
Model names
Phoenix Contact GmbH & Co. KG
SZS 0.4×2.5
0.4 mm
2.5 mm
With
straight tip
TC-ADP
:
represents the channel number.
Terminal
block
Grounding
(Ground resistance: 100
or less)
Compensating lead
wire (Shielded)
Thermocouple
L
-
L
+
PLC
Othere
quipment
PLC
Othere
quipment
PLC
Othere
quipment
Shared grounding
(Good condition)
Common grounding
(Not allowed)
Independent grounding
(Best condition)
4. Specifications
4.1 Applicable CPU Module
4.2 General Specifications
The items other than the following are equivalent to those of the CPU module.
For general specifications, refer to the following manual.
MELSEC iQ-F FX5U User's Manual (Hardware)
MELSEC iQ-F FX5UC User's Manual (Hardware)
4.3 Power Supply Specifications
STARTUP AND
MAINTENANCE
PRECAUTIONS
Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
For repair, contact your local Mitsubishi Electric representative.
Do not drop the product or exert strong impact to it.
Doing so may cause damage.
DISPOSAL PRECAUTIONS
Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.
TRANSPORTATION
PRECAUTIONS
The product is a precision instrument. During transportation, avoid impacts larger
than those specified in the general specifications by using dedicated packaging
boxes and shock-absorbing palettes.
Failure to do so may cause failures in the product.
After transportation, verify operation of the product and check for damage of the
mounting part, etc.
Model name
Applicability
FX5U CPU module
Ver. 1.040 or later
FX5UC CPU module
Ver. 1.040 or later
Item
Specification
Dielectric withstand
voltage
500 V AC for one minute
B e t w e e n a l l e x t e r n a l
t e r m i n a l s a n d g r o u n d
terminal of CPU module
Insulation resistance
10 M
or higher by 500 V DC
insulation resistance tester
Item
Specification
Internal electric supply
(A/D conversion circuit)
24 V DC 20 mA
Internal electric supply is carried out from 24 V DC power
supply of a CPU module.
Internal electric supply
(Interface)
5 V DC 10 mA
Internal electric supply is carried out from 5 V DC power
supply of a CPU module.
4.4 Performance Specifications
*1 To satisfy the accuracy, it is required to warm up (supply power) for 45 min.
*2 The accuracy differs depending on the range of the measured temperature in ().
*3 For details of the conversion speed, refer to the following manual.
MELSEC iQ-F FX5 User's Manual (Analog Control)
Item
Specification
Centigrade (°C)
Fahrenheit (°F)
Number of analog input points
4 points (4 channels)
Usable thermocouple
K, J, T, B, R, S
Temperature measuring range
K -200 to +1200°C
-328 to +2192
F
J
-40 to +750°C
-40 to +1382
F
T -200 to +350°C
-328 to +662
F
B 600 to 1700°C
1112 to 3092
F
R 0 to 1600°C
32 to 2912
F
S 0 to 1600°C
32 to 2912
F
Digital output value
16-bit signed binary
K -2000 to +12000
-3280 to +21920
J
-400 to +7500
-400 to +13820
T -2000 to +3500
-3280 to +6620
B 6000 to 17000
11120 to 30920
R 0 to 16000
32 to 29120
S 0 to 16000
32 to 29120
Accuracy
*1
Ambient temperature
25±5°C
K
±3.7°C (-100 to +1200°C)
*2
±4.9°C (-150 to -100°C)
*2
±7.2°C (-200 to -150°C)
*2
J
±2.8°C
T
±3.1°C (0 to 350°C)
*2
±4.1°C (-100 to 0°C)
*2
±5.0°C (-150 to -100°C)
*2
±6.7°C (-200 to -150°C)
*2
B ±3.5°C
R ±3.7°C
S ±3.7°C
Ambient temperature
-20 to 55°C
K
±6.5°C (-100 to +1200°C)
*2
±7.5°C (-150 to -100°C)
*2
±8.5°C (-200 to -150°C)
*2
J
±4.5°C
T
±4.1°C (0 to 350°C)
*2
±5.1°C (-100 to 0°C)
*2
±6.0°C (-150 to -100°C)
*2
±7.7°C (-200 to -150°C)
*2
B ±6.5°C
R ±6.5°C
S ±6.5°C
Resolution
K, J, T
0.1°C
0.1 to 0.2
F
B, R, S
0.1 to 0.3°C
0.1 to 0.6
F
Conversion speed
Approx. 85 ms/channel
*3
Isolation method
Between input terminal and CPU module:
Photocoupler
Between input channels: Non-isolation
Number of occupied I/O points
0 point (This number is not related to the
maximum number of I/O points of the PLC.)
MELSEC iQ-F FX5-4AD-TC-ADP
Hardware Manual
This manual describes the part names, dimensions, installation, and
specifications of the product. Before use, read this manual and manuals of
relevant products fully to acquire proficiency in handling and operating the
product. Make sure to learn all the product information, safety information, and
precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration:
The company name and the product name to be described in this manual are the
registered trademarks or trademarks of each company.
Effective October 2016
Specifications are subject to change without notice.
2016 MITSUBISHI ELECTRIC CORPORATION
Manual Number
JY997D66701
Revision
A
Date
October 2016