73
11.5 Outside dimensions and general specification
Accessories
Weight : Approximately 3.5 kg
Main unit mounting legs : One pair
Painting color : Munsell 7.5Y 7.5/1
Screws fixing main unit and mounting legs : M4
×
10 ,4screws
Screws of 10 mm or more are not applicable because
such screws may make contact with parts inside the
main unit.
When the unit is installed on the floor or wall, use
these screws to fix the main unit and mounting legs.
Ambient temperature
0 ~ 40
°
c
during operation
Ambient humidity
80% RH or less ( no condensation) during operation
Vibration resistance
10 to 55 Hz, 0.5mm (4. 9m / s
2
maximum), 2 hours in each of three axis directions .
Impact resistance
98m / s
2
, 3 times in each of three axis directions.
Supply noise resistance
By noise simulator with 1,000 Vp-p noise voltage, 1
µ
s noise width and 30 to 100 Hz
cycle.
Withstand voltage
1,500V AC, 1 minute
Entire terminals as a whole and between the
ground terminal.
Insulation resistance
5M
Ω
or more by 500V DC megger
Grounding
Solid grounding (100
Ω
or less)
Operating atmosphere
No corrosive gas and little dust
Power switch cycles
Less than 20,000 times
1. Outside dimensions
246
228
244
256
156
16.5
140
16
15
80
100
80
100
14
8
5
12
12 MAX
MODE
CANCEL
MONITOR
N
%
X10N
LE-40MTB-E
TENSION CONTROLLER
OUTPUT
ON/OFF
POWER
ON
OFF
MENU
SHIFT
MENU7
MENU3
MENU6
MENU2
MENU5
MENU4
MENU1
MENU0
DISPLAY
TENSION
SET
PAGE
MANUAL
SET
CURSOR
ENTER
MANUAL
AUTO
SELECT
2. General and environmental specifications
Содержание LE-40MTB-E
Страница 2: ......
Страница 4: ......
Страница 79: ......
Страница 80: ...JZ990D30801F TENSION CONTROLLER MODEL LE 40MTB E ...