3
1.2 Panel configuration
The figure below shows the configuration of the panel of the tension controller LE-40MTA-E.
Turn on the POWER switch and the OUTPUT ON/OFF switch to light the LEDs provided on the upper
portion of the both switches.
(Note) Use OUTPUT ON/OFF switch or OUT REMOTE input without using the POWER
switch when the output is turned on and off.
• Allowable power switch cycles : 20,000 times
The monitored operating tension value is always displayed in the bar graph on the upper right of the
screen.
Under the bar graph, the operating tension or control output is displayed in numeric.
The control output or the operating tension is displayed on the seven-segment display in the same way.
The type of contents displayed is changed every time the Tension/Output selector switch is pressed. The
type of contents displayed on the seven-segment display is indicated by the LED provided on the left
side of the selector switch.
The unit of tension (
×
10N or N) is specified by the setting of the parameter.
When the AUTO switch is pressed, the unit performs automatic oper-
ation. However, automatic control is not performed if the operation/
stop input is not turned on.
The tension set value changes from 0 to full scale value in accor-
dance with the scale of the tension set trimmer of 0 to 10.
The full scale tension is set in the initial setting.
When the taper tension is controlled in accordance with the reel diam-
eter, the tension set value subtracted by the taper tension is regarded
as actual target tension and used during automatic control.
When the MANUAL switch is pressed, manual operation is available.
The control output of 0
~
100% can be obtained with the scale of the
manual torque set trimmer 0
~
10. (The output is 0
~
5V both in the ser-
vo mode and the powder mode.)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(13)
(12)
(14)
(16)
(15)
(17)
(20)
(19)
(18)
(21)
(22)
(23)
(25)
(24)
-E
OUTP UT
ON/ OFF
POWER
ON
OFF
ENTE R
CANCE L
INC/ DE C
P AGE
CURS OR
MODE
MANUAL
AUTO
TE NS ION S E T
MANUAL S ET
MONITOR
S ELE CT
1. POWER switch and OUTPUT ON / OFF switch
2. DISPLAY SELECTOR switch
→
Se
t te
ns
io
n (
N
)
Full scale tension
Left Trimmer Right
0
2
4
6
8
10
Tension set
→
C
on
trol output (
%
)
Left Trimmer Right
0
2
4
6
8
10
20
40
60
80
100
Manual set
3. Automatic operation ( Basic operation )
4. Manual operation
(1) : POWER switch
(2) : Power LED
(3) : Output ON/OFF switch
(4) : Output ON/OFF LED
(5) : LCD display
(6) : Bar graph
Upper :Tension monitor (%)
Lower :Target tension (%)
(7) : Scale
(8) : Seven-segment display
(9) : Unit LED
(10) : DISPLAY SELECTOR
Tension and output are
selected alternately.
Selection of kgf or N is
set by the parameter.
(11)
: Door open screw
(12)
: MANUAL mode switch
(13)
: Manual mode LED
(14)
: Manual torque set
trimmer
(15)
: AUTO mode switch
(16)
: Automatic mode LED
(17)
: TENSION SET trimmer
(18)(19) : Screen scroll keys
(20)(21) : Cursor contorol keys
(22)(23) : Numeric input keys
(24)
: CANCEL key
(25)
: ENTER key
Содержание LE-40MTA-E
Страница 2: ......
Страница 4: ......
Страница 57: ......
Страница 58: ...JZ990D30601E TENSION CONTROLLER MODEL LE 40MTA E ...