47
Items
Terminal
Specifications
Analog
signals
Input
AI2
Diameter : Reel diameter signal for external taper control.
0 ~ 5 V corresponding to minimum value to maximum value.
Stall
: External stall setting signal.
0 ~ 5 V corresponding to 0 ~ 100% output torque.
New reel : New reel preset
0 ~ 5 V corresponding to 0 ~ 100% output torque.
Taper ratio: External taper ratio setting
0 ~ 5 V corresponding to:
• 0 ~ 80% (internal diameter taper)
• 0 ~ 100% (external diameter taper)
Tension
: Auxiliary tension input
0 ~ 5V corresponding to 0 to full-scale tension
• Function is specified by parameter.
• Internal resistance:100k
Ω
AI3
Output
SA
Control signal output
• Powder mode
: 0 ~ 5 VDC
• AC servo mode : 0 ~
±
5 VDC
• Load resistance : 1 k
Ω
or more
For power amplifier
servo amplifier
SN
NRO
New reel preset output
• Effective exclusively when "REELS" mode is
selected.
• 0 ~ 5 VDC
• Load resistance : 1 k
Ω
or more
AOC
TMO
Tension monitor output
• Filter can be adjusted by parameter.
• 0 ~ 5 VDC
• Load resistance : 1 k
Ω
or more
For tension
meter recorder
AOC
EAP
Control signal output for E/P regulator
• 4 ~ 20 mADC
• Load resistance : 470
Ω
or less
For
air clutch
air brake
EAN
P
Power output for 24 VDC system powder clutch/brake and hysteresis
clutch/brake.
• 0 ~ 24 VDC, 4 A or less
N
Содержание LE-40MTA-E
Страница 2: ......
Страница 4: ......
Страница 57: ......
Страница 58: ...JZ990D30601E TENSION CONTROLLER MODEL LE 40MTA E ...