3 - 23 3 - 23
MELSEC-Q
3 SPECIFICATIONS
Device No.
Signal Name
Description
[In offset/gain setting mode]
(1) This signal is used as an interlock condition to turn ON/OFF the User range writing
request (YA) when the value at completion of offset/gain setting adjustment is
registered.
(2) See Section 4.6 regarding the offset/gain settings.
OFF
Module ready (X0)
Offset/gain setting mode flag (XA)
User range writing request (YA)
Performed by the A/D converter module
Performed by the sequence program
XA
Offset/gain
setting mode flag
[In normal mode]
(1) This signal is used as an interlock condition to turn ON/OFF the User range writing
request (YA) when the user range is restored.
(2) Refer to Chapter 7 for the user range restoration.
ON
Performed by the A/D converter module
Performed by the sequence program
Module ready (X0)
Offset/gain setting mode flag (XA)
User range writing request (YA)
Содержание GX Configurator-AD
Страница 2: ......
Страница 23: ...2 6 2 6 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Страница 120: ...5 31 5 31 MELSEC Q 5 UTILITY PACKAGE GX Configurator AD MEMO ...
Страница 145: ...6 25 6 25 MELSEC Q 6 PROGRAMMING MEMO ...
Страница 207: ......