background image

This manual confers no industrial property rights or any rights of any other kind, 
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be 
held responsible for any problems involving industrial property rights which may 
occur as a result of using the contents noted in this manual.

Warranty

Mitsubishi will not be held liable for damage caused by factors found not to be 
the cause of Mitsubishi; opportunity loss or lost profits caused by faults in the 
Mitsubishi products; damage, secondary damage, accident compensation 
caused by special factors unpredictable by Mitsubishi; damages to products 
other than Mitsubishi products; and to other duties.

For safe use

This product has been manufactured as a general-purpose part for general 
industries, and has not been designed or manufactured to be incorporated in 
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric 
power, aerospace, medicine or passenger movement vehicles, consult with 
Mitsubishi Electric.
This product has been manufactured under strict quality control. However 
when installing the product where major accidents or losses could occur if the 
product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE

HIMEJI WORKS

 : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, 
   JAPAN
 : 840, CHIYODA CHO, HIMEJI, JAPAN

Side

B

Side

A

Side

B

JAPANESE

ENGLISH

JY997D32901A

Safety Precaution

 

(Read these precautions before using.)

Before using this product, please read this manual and the relevant manuals introduced

in this manual carefully and pay full attention to safety to handle the product correctly.

The precautions given in this manual are concerned with this product.

In this manual, the safety precautions are ranked as "DANGER" and "CAUTION".

Depending on circumstances, procedures indicated by "CAUTION" may also be

linked to serious results. 

In any case, it is important to follow the directions for usage.       

Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous

conditions, resulting in medium or slight personal injury

or physical damage.

DESIGN PRECAUTIONS

Some failures of the GOT or cable may keep the outputs on or off.

An external monitoring circuit should be provided to check for output signals

which may lead to a serious accident.

Not doing so can cause an accident due to false output or malfunction.

If a communication fault (including cable disconnection) occurs during

monitoring on the GOT, communication between the GOT and PLC CPU is

suspended and the GOT becomes inoperative.

A system where the GOT is used should be configured to perform any

significant operation to the system by using the switches of a device other

than the GOT on the assumption that a GOT communication fault will occur.

Not doing so can cause an accident due to false output or malfunction.

Do not use the GOT as the warning device that may cause a serious accident.

An independent and redundant hardware or mechanical interlock is required to

configure the device that displays and outputs serious warning.

Failure to observe this instruction may result in an accident due to incorrect

output or malfunction.

Incorrect operation of the touch switch(s) may lead to a serious accident if the

GOT backlight is gone out.

When the GOT backlight goes out, causes the monitor screen to appear

blank, while the input of the touch switch(s) remains active.

This may confuse an operator in thinking that the GOT is in "screensaver"

mode, who then tries to release the GOT from this mode by touching the

display section, which may cause a touch switch to operate.

DESIGN PRECAUTIONS

Do not bundle the control and communication cables with main-circuit, power

or other wiring.

Run the above cables separately from such wiring and keep them a minimum

of 100mm (3.94in.) apart.Not doing so noise can cause a malfunction.

MOUNTING 
PRECAUTIONS

Be sure to shut off all phases of the external power supply used by the

system before mounting or removing the GOT to/from the panel.

Not doing so can cause the unit to fail or malfunction.

When installing the battery wear an earth band etc. to avoid the static electricity.

The static electricity can cause the unit to fail or malfunction.

MOUNTING PRECAUTIONS

Use the GOT in the environment that satisfies the general specifications

described in this manual. Not doing so can cause an electric shock, fire,

malfunction or product damage or deterioration.

When mounting the GOT to the control panel, tighten the mounting screws in the

specified torque range. Undertightening can cause the GOT to drop, short circuit

or malfunction. Overtightening can cause a drop, short circuit or malfunction due

to the damage of the screws or the GOT.

WIRING PRECAUTIONS

Be sure to shut off all phases of the external power supply used by the system

before wiring. Failure to do so may result in an electric shock, product damage or

malfunctions.

Please make sure to ground FG terminal of the GOT power supply section by

applying 100 or less which is used exclusively for the GOT. Not doing so may

cause an electric shock or malfunction.

Correctly wire the GOT power supply section after confirming the rated voltage

and terminal arrangement of the product. Not doing so can cause a fire or failure.

Tighten the terminal screws of the GOT power supply section in the specified

torque range. Undertightening can cause a short circuit or malfunction.

Overtightening can cause a short circuit or malfunction due to the damage of the

screws or the GOT.

Exercise care to avoid foreign matter such as chips and wire offcuts entering the

GOT. Not doing so can cause a fire, failure or malfunction.

WIRING PRECAUTIONS

Plug the communication cable into the connector of the connected unit and

tighten the mounting and terminal screws in the specified torque range.

Undertightening can cause a short circuit or malfunction. Overtightening can

cause a short circuit or malfunction due to the damage of the screws or unit.

TEST OPERATION 
PRECAUTIONS

Before performing the test operations of the user creation monitor screen (such as

turning ON or OFF bit device, changing the word device current value, changing

the settings or current values of the timer or counter), read through the manual

carefully and make yourself familiar with the operation method.

During test operation, never change the data of the devices which are used to

perform significant operation for the system. False output or malfunction can

cause an accident.

STARTUP/MAINTENANCE 
PRECAUTIONS

When power is on, do not touch the terminals.

Doing so can cause an electric shock or malfunction.

Connect the battery correctly.

Do not discharge, disassemble, heat, short, solder or throw the battery into the fire.

Incorrect handling may cause the battery to generate heat, burst or take fire,

resulting in injuries or fires.

Before starting cleaning or terminal screw retightening, always switch off the

power externally in all phases. Not switching the power off in all phases can cause

a unit failure or malfunction. Undertightening can cause a short circuit or

malfunction. Overtightening can cause a short circuit or malfunction due to the

damage of the screws or unit.

STARTUP/MAINTENANCE 
PRECAUTIONS

Do not disassemble or modify the unit.

Doing so can cause a failure, malfunction, injury or fire.

Do not touch the conductive and electronic parts of the unit directly.

Doing so can cause a unit malfunction or failure.

The cables connected to the unit must be run in ducts or clamped.

Not doing so can cause the unit or cable to be damaged due to the dangling,

motion or accidental pulling of the cables or can cause a malfunction due to a

cable connection fault.

When unplugging the cable connected to the unit, do not hold and pull the cable

portion. Doing so can cause the unit or cable to be damaged or can cause a

malfunction due to a cable connection fault.

Do not drop or apply any impact to the battery.
If any impact has been applied, discard the battery and never use it.
The battery may be damaged by the drop or impact.

Before touching the unit, always touch grounded metal, etc. to discharge static

electricity from human body, etc.

Not doing so can cause the unit to fail malfunction.

DISPOSAL PRECAUTIONS

When disposing of the product, handle it as industrial waste.

Compliance with EC directive (CE Marking)

This note does not guarantee that an entire mechanical module produced in
accordance with the contents of this note will comply with the following standards.
Compliance to EMC directive for the entire mechanical module should be checked by
the user / manufacturer. For more details please contact the local Mitsubishi Electric
sales site.

Requirement for Compliance with EMC directive

The following products have shown compliance through direct testing (to the
identified standards) and design analysis (forming a technical construction file) to the
European Directive for Electromagnetic Compatibility (89/336/EEC) when used as
directed by the appropriate documentation.
Type :Programmable Controller (Open Type Equipment)

For more details please contact the local Mitsubishi Electric sales site.

Notes for compliance to EMC regulation

1) General notes on the use of communication cables

Any device which utilizes a data communication function is susceptible to the
wider effects of local EMC noise. Therefore, when installing any communication
cables care should always be taken with the routing and location of those cables.
The GOT units identified on the previous chapter are compliant with the EMC
requirement when the following communication cables are used.

2) General notes on Power supply

The GT1045-QSBD and GT1040-QBBD unit
requires an additional ferrite filter to be
attached to the 24V DC power supply
cables. The filter should be attached in a
similar manner as shown in the figure
opposite, i.e. the power cables are wrapped
around the filter. However, as with all EMC
situations the more correctly applied
precautions the better the systems Electro-
m a g n e t i c   C o m pa t i b i l i t y.   T h e   f e r r i t e
recommended is a TDK ZCAT3035-1330 or
similar. The ferrite should be placed as near
to the 24V DC terminals of the GT1045-
QSBD and GT1040-QBBD as possible
(which should be within 75mm of the GOT
terminal).

Associated Manuals

The following manuals are relevant to this product. When these loose manuals are
required, please consult with our local distributor.

*1 Stored in the GT Works 2/GT Designer2 in PDF format.

For details of a PLC to be connected, refer to the PLC user's manual respectively.

Bundled Items 

TRANSPORTATION 
PRECAUTIONS

Before transporting the GOT, turn the GOT power on and check that the battery

voltage status is normal on the Time setting & display screen (utilities screen). In

addition, confirm that the adequate battery life remains on the rating plate.

Transporting the GOT with the low battery voltage or the battery the reached

battery life may unstabilize the backup data unstable during transportation.

Make sure to transport the GOT main unit and/or relevant unit(s) in the manner

they will not be exposed to the impact exceeding the impact resistance

described in the general specifications of this manual, as they are precision

devices. Failure to do so may cause the unit to fail.

Check if the unit operates correctly after transportation.

Standard

Remark

EN61131-2 : 2003
Programmable 
controllers- Equipment, 
requirement and tests

EMI

Compliance with all relevant aspects of the 
standard.
(Radiated Emissions)

EMS

Compliance with all relevant aspects of the 
standard.
(ESD, RF electromagnetic field, EFTB, Surge, RF 
conducted disturbances and Power frequency 
magnetic field)

GOT Unit

Existing Cables

User Made Cables

GT1045-QSBD 

and 

GT1040-QBBD

GT01-C30R4-8P 

modified as 

shown in EX.1

Those cables need to be independently
tested by the user to demonstrate EMC
compatibility when they are used with
M i t s u b i s h i   G O T   u n i t   a n d   F X

3 U

Programmable Controllers.

100mm

250mm

140mm

GT01-C30R4-8P

Comes equipped

Added by user

GOT units

F = Ferrite core
Ex. NEC TOKIN - ESD-R-17S or similar

Programmable
controller

Added by user

(9.84inch)

(3.93inch)

(5.51inch)

Ex.1

F

F

F

Manual name

Contents

Manual Number

(Model Code)

GT10 User's Manual 

(sold separately)

Describes the GT10 hardware-relevant

content such as part names, external

dimensions, mounting, power supply

wiring, specifications, and introduction

to option devices

JY997D24701

(09R819)

GOT1000 Series 

Connection Manual 

1/3, 2/3, 3/3
(sold separately) 

*1

Describes system configurations of the

connection method applicable to

GOT1000 series and cable creation

method

SH-080532ENG

(1D7M26)

GT Designer2 Version2 

Basic Operation/Data 

Transfer Manual 

(For GOT1000 Series)
(sold separately) 

*1

D e s c r i b e s   m e t h o d s   o f   t h e   GT

Designer2 installation operation, basic

operation for drawing and transmitting

data to GOT1000 series

SH-080529ENG

(1D7M24)

GT Designer2 Version2 

Screen Design Manual

(For GOT1000 Series) 

1/3, 2/3, 3/3
(sold separately) 

*1

Describes specifications and settings

of the object functions used in GT

Designer2

SH-080530ENG

(1D7M25)

Model Name

Remark

GT1045-QSBD

GOT main unit

(The maintenance supplies below are packed with the product.)

GT1040-QBBD

Maintenance Supplies

Quantity

Panel Mounting Bracket (with M4 

×

 20 screws)

4

Panel Mounting Packing

1

GT10 General Description (This manual)

1

TDK

Up to
75mm
(2.95inch)

Explanation of the GOT model name

GT10 4 0  -

* * * *

0:Monochrome(black/white)

5:256 colors supported

GOT1000 series

GT10

Screen size type

Display color type

Display device type

B:Black

Power type

Panel color type

D:24VDC

L:5VDC

4:4.7"
3:4.5"

5:5.7"

2:3.7"

L:STN monochrome(black/white)
B:STN monochrome(blue/white)

S:STN color

Resolution

Blank:less than 320 

×

 240

Q:320 

×

 240(QVGA)

1. Specifications

1.1 General Specifications

*1 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude 0m (0ft.). Failure to observe this instruction may cause a malfunction.
*2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the

machinery within the premises.

Category II applies to equipment for which electrical power is supplied from fixed facilities.

The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V.

*3 This index indicates the degree to which conductive material is generated in the environment where the equipment is used.

In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be produced due to condensation.

1.2 Performance Specifications

Item

Specifications

GT1045-QSBD/GT1040-QBBD

Operating ambient 

temperature

Display section

0 to 50

°

C

Other than display section 0 to 55

°

C (When mounted horizontally), 0 to 50

°

C (When mounted vertically)

Storage ambient temperature

-20 to 60

°

C

Operating ambient humidity

10 to 90% RH, non-condensing (The wet bulb temperature is 39

°

C or less.)

Storage ambient humidity

10 to 90% RH, non-condensing (The wet bulb temperature is 39

°

C or less.)

Vibration resistance

Conforms to JIS 

B3502 and 

IEC61131-2

Frequency

Acceleration

Half-amplitude

Sweep Count

Under intermittent

vibration

5 to 9Hz

--

3.5mm

10 times each in X, 

Y and Z directions

9 to 150Hz

9.8m/s

2

--

Under continuous

vibration

5 to 9Hz

--

1.75mm

9 to 150Hz

4.9m/s

2

--

Shock resistance

Conforms to JIS B3502, IEC 61131-2 (147m/s

2

, 11 ms, Sine half-wave pulse, 3 times each in the X, Y, and Z directions.)

Operating atmosphere

Must be free of lamp black, corrosive gas, flammable gas, or excessive amount of electroconductive dust particles and

must be no direct sunlight. (Same as for saving)

Operating altitude

*1

2000 m (6562 ft) max.

Installation location

Inside control panel

Overvoltage category

*2

II or less

Pollution degree

*3

2 or less

Cooling method

Self-cooling

Grounding

Class D grounding (100

 or less). To be connected to the panel when grounding is not possible

Item

Specifications

GT1045-QSBD

GT1040-QBBD

Display 
section

*1

Type

STN color liquid crystal

STN monochrome (white/blue) liquid crystal

Screen size

4.7"

Resolution

320 

×

 240 dots (Horizontal format)

Display size

W96(3.77) 

×

 H72(2.83) [mm](inch) (Horizontal format)

Display character

16-dot standard font: 40 characters 

×

 15 lines, 12-dot standard font: 53 characters 

×

 20 lines (Horizontal format)

Display color

256 colors

Monochrome (white/blue), 16 scales

Display angle

Left/Right: 50 degrees, Top: 40 degrees, Bottom: 70 degrees

(Horizontal format)

Left/Right: 45 degrees, Top: 20 degrees, Bottom: 40 degrees

(Horizontal format)

Contrast adjustment

16-level adjustment

Intensity of LCD only

150 [cd/m

2

]

300 [cd/m

2

]

Life

Approx. 50,000h. (Time for display intensity to become 1/5 at operating ambient temperature of 25

°

C)

Backlight

LED      Backlight off/screen saving time can be set.

Touch

panel

Number of touch keys

Maximum 50 keys/screen (Matrix resistive film touch panel)

Key size

Minimum 16 

×

 16 dots (per key)

Simultaneous pressing of

two (or more) areas

(2-point press)

Enable

Life

1 million times or more (operating force 0.98N max.)

Memory

User memory

*2

Flash memory ROM (Internal), for storing project data (3M bytes or less) and OS

Life 

(Number of write times)

100,000 times

Battery

GT11-50BAT lithium battery

Backup target

Clock data, alarm history and recipe data

Life

Approx. 5 years (Operating ambient temperature of 25)

Buzzer output

(a buzzer that sounds when touch

keys are pressed)

Single tone (LONG/ SHORT/ OFF adjustable)

Environmental protective structure

*3

Equivalent to IP67 (JEM1030) (front section)

External dimensions

W139(5.47) 

×

 H112(4.4) 

×

 D41(1.61)[mm](inch) (Excluding mounting fixtures) (Horizontal format)

*1 Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display

comprises of a great number of display elements. Flickers may be observed depending on the display color. 

Please note that these dots appear due to its characteristic and are not caused by product defect.

When the same screen is displayed for a long time, an incidental color or partial discoloration is generated on the screen due to heat damage, and it may not disappear.

To prevent heat damage, the screen saver function is effective.

For details on the screen saver function, refer to the following.

 GT10 User's Manual

*2 ROM in which new data can be written without deleting the written data.
*3 Note that this does not guarantee all users' operation environment.

1.3 Power Supply Specifications

(

For details on power supply wiring, such as the allowable cable size and tightening

torque, refer to the additional manual, "GT10 User's Manual".)

*1 The GOT continues to operate even upon 5ms or shorter instantaneous

power failure.

The GOT stops operating if there is extended power failure or voltage drop,

while it automatically resumes operation as soon as the power is restored.

Built-in 

interface

RS-422

RS-422   1ch

Transmission speed: 115,200/57,600/38,400/19,200/9,600/4,800bps

Connector shape

: D-sub 9-pin (Female)

Application

: PLC communication

RS-232

RS-232   1ch

Transmission speed : 115,200/57,600/38,400/19,200/9,600/4,800bps

Connector shape

: D-sub 9-pin (Male)

Application

: PLC communication, bar code reader connection, PC communication 

(Project data upload/download, OS installation, transparent function)

USB

USB (Full Speed 12Mbps)  1ch

Connector shape: Mini-B (Receptacle)

Application: PC communication (Project data upload/download, OS installation, transparent function)

GT10-50FMB

For connecting GT10-50FMB memory board

Panel cutting dimensions

W130 (5.11”) 

×

 H103(4.05”) [mm] (inch) (Horizontal format)

Weight

0.45kg (Excluding mounting fixtures)

Compatible software package

GT Designer2 Version 2.85P or later

Item

Specifications

GT1045-QSBD

GT1040-QBBD

Item

Specifications

GT1045-QSBD

GT1040-QBBD

Input power supply 

voltage

24VDC (+10%  -15%)

Fuse (built-in, not 

exchangeable)

1.0A

Power 

consumption, 

(At backlight off)

3.6W (150mA/24VDC) or less, 

(2.9W (120mA/24VDC) or less)

Inrush current

15A or less (26.4VDC) 2ms

Permissible 

instantaneous 
power failure time

*1

Within 5ms

Noise immunity

Noise voltage: 1000Vp-p, Noise width: 1

µ

s (by noise 

simulator of 30 to 100Hz noise frequency)

Dielectric withstand 

voltage

500VAC for 1 minute (across power supply terminals and 

earth)

Insulation 

resistance

10M

 or larger by insulation resistance tester (across power 

supply terminals and earth)

GT1045-QSBD, GT1040-QBBD

GT10 General Description

This manual describes the specifications of the product. Before use, read this
manual and manuals of relevant products fully to acquire proficiency in handling
and operating the product. Make sure to learn all the product information, safety
information, and precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this manual are
the registered trademarks or trademarks of each company.

Effective Aug 2008
Specifications are subject to change without notice.

©

 2008 Mitsubishi Electric Corporation

Manual Number

JY997D32901A

Date

Aug 2008