14. CONNECTION TO SIEMENS PLC
14.4 Device Range that Can Be Set
14 - 17
CONNECTION T
O
SIEME
N
S PLC
14
14.4.1
SIEMENS S7-300/400 Series
*1
Monitoring or writing is not possible in the continuous device
designation mode.
14.4.2
SIEMENS S7-200 Series
*1
Only reading is possible.
*2
Only reading 32-bit (two-word data) designation is allowed.
*3
Writing is possible only while the PLC is running.
*4
Only 16-bit (1-word) designation is allowed.
14.4.3
SIEMENS S7 (Ethernet)
*1
Monitoring or writing is not possible in the continuous device
designation mode.
14.4.4
SIEMENS OP (Ethernet)
*1
Data format to input into Timer (T), Counter (C) varies
according to a type of the PLC.
• S7-300/400: BCD code
• S7-200: BIN code
*2
S-1200 does not support Timer (T), Counter (C).
*3
Writing is possible only while the PLC is running.
*4
Only 16-bit (1-word) designation is allowed.
Device name
Setting range
Device
No.
represen
tation
Bi
t de
vi
ce
Input relay (I)
I0000 to I5117
Decimal
Output relay (Q)
Q0000 to Q5117
Bit memory (M)
M00000 to M20477
Word device bit
Specified bit of the
following word devices
―
W
o
rd
device
Input relay (IW)
IW0 to IW510
Decimal
Output relay (QW)
QW0 to QW510
Bit memory (MW)
MW0 to MW2046
Timer (Current value) (T)
*1
T0 to T511
Counter (Current value)
(C)
C0 to C511
Data register (DB)
DB1.DBW0 to
DB1.DBW65534
DB2.DBW0 to
DB2.DBW65534
.
.
DB4094.DBW0 to
DB4094.DBW65534
DB4095.DBW0 to
DB4095.DBW65534
Device name
Setting range
Device
No.
represen
tation
Bi
t de
vi
ce
variable memory (V)
V0 to V51197
Decimal
Input relay (I)
I0 to I77
Output relay (Q)
*3
Q0 to Q77
Bit memory (M)
M0 to M317
special memory (SM)
SM0 to SM1947
Timer (T)
*1
T0 to T255
Counter (C)
*1
C0 to C255
sequence control relay (S)
S0 to S317
W
o
rd device
variable memory (VW)
VW0 to VW5118
Decimal
Input relay (IW)
IW0 to IW6
Output relay (QW)
*3
QW0 to QW6
analog input (AIW)
*1
AIW0 to AIW30
analog output (AQW)
*3
AQW0 to AQW30
Bit memory (MW)
MW0 to MW30
special memory (SMW)
SMW0 to SMW192
Timer (T)
*4
T0 to T255
Counter (C)
*4
C0 to C255
High-speed counter (HC)
*2
HC0 to HC2
sequence control relay
(SW)
SW0 to SW30
Device name
Setting range
Device
No.
represen
tation
Bit
device
Input relay (I)
I0000 to I1277
Decimal
Output relay (Q)
Q0000 to Q1277
Bit memory (M)
M0000 to M2557
Word device bit
Specified bit of the
following word devices
Data register
―
W
o
rd device
Input relay (IW)
IW0 to IW126
Decimal
Output relay (QW)
QW0 to QW126
Bit memory (MW)
MW0 to MW254
Timer (Current value) (T)
*1
T0 to T255
Counter (Current value) (C)
C0 to C255
Data register (DB)
DB1.DBW0 to
DB1.DBW2046
DB2.DBW0 to
DB2.DBW2046
.
.
DB254.DBW0 to
DB254.DBW2046
DB255.DBW0 to
DB255.DBW2046
Device name
Setting range
Device
No.
represen
tation
B
it device
variable memory (V)
V0 to V102397
Decimal
Input relay (I)
I0 to I655357
Output relay (Q)
*3
Q0 to Q655357
Bit memory (M)
M0 to M655357
Word device bit
Specified bit of the following
word devices (Except
variable memory, Input
relay, Output relay, Bit
memory, Timer, Counter)
W
o
rd
de
vi
ce
variable memory (VW)
VW0 to VW10238
Decimal
Input relay (IW)
IW0 to IW65534
Output relay (QW)
*3
QW0 to QW65534
Bit memory (MW)
MW0 to MW65534
Timer (T)
*1*2*4
T0 to T65535
Counter (C)
**1*2*4
C0 to C65535
Data register (DB)
DB1.DBW0 to
DB1.DBW65534
DB2.DBW0 to
DB2.DBW65534
:
DB4094.DBW0 to
DB4094.DBW65534
DB4095.DBW0 to
DB4095.DBW65534
Содержание GOT2000Series
Страница 2: ......
Страница 17: ...A 15 REVISIONS WARRANTY...
Страница 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Страница 54: ......
Страница 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Страница 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Страница 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Страница 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Страница 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Страница 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Страница 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Страница 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Страница 334: ...REVISIONS 2...
Страница 337: ......