14. CONNECTION TO SIEMENS PLC
14.3 Ethernet Connection
14 - 13
CONNECTION T
O
SIEME
N
S PLC
14
(2) Ethernet connection type: OP communication
This section describes the Ethernet setting for the
communication driver SIEMENS OP (Ethernet).
*1
Connection No./Rack No. and Module Position/Slot No. are
unnecessary for S7-1200 OP.
14.3.4
PLC side setting
POINT
POINT
POINT
SIEMENS PLC
For details of SIEMENS PLCs, refer to the following
manuals.
SIEMENS PLC user's Manual
Parameter settings
Set the following parameters with the SIEMENS
software package.
(1) Ethernet connection type: FETCH/WRITE
(a) Settings of IP address and subnet mask
(b) Fetch port setting
(c) Write port setting
(d) Precautions for setting
The Keep Alive function of the Siemens CP Module
is not supported. Specify 0 for [Keep Alive].
Item
Description
Set value
Host
The host is displayed. (The host is
indicated with an asterisk (*).)
―
Net No.
Set the network No. of the
connected Ethernet module.
(Default: blank)
1 to 239
Station
Set the station No. of the connected
Ethernet module.
(Default: blank)
1 to 254
Type
Set the PLC type to be connected.
S7-200 OP
S7-300/400 OP
S7-1200 OP
IP Address
Set the IP address of the connected
Ethernet module.
(Default: blank)
PLC side IP
address
Port No.
102 (fixed)
102 (fixed)
Connection
No./Rack No.
*1
Set the Connection No./Rack No. set
on the PLC side.
(Default: 0)
0 to 7
Module
Position/Slot
No.
*1
Set the Module Position/Slot No. set
on the PLC side.
(Default)
S7-200 OP: 0
S7-300/400 OP: 2
S7-200
OP: 0 to 6
S7-300/400
OP: 0 to 31
Communication TCP (fixed)
TCP (fixed)
Item
Setting details
Parameters
IP Address
PLC side IP address
Subnet
mask
PLC side subnet mask
Item
Setting details
Options
Mode
Select [Fetch passive].
Addresses
IP(dec)
Local
PLC side IP address
Remote
GOT side IP address
PORT
(dec)
Local
PLC side port No.
Remote
GOT side port No.
Item
Setting details
Options
Mode
Select [Write passive].
Addresses
IP(dec)
Local
PLC side IP address
Remote
GOT side IP address
PORT
(dec)
Local
PLC side port No.
Remote
GOT side port No.
Содержание GOT2000Series
Страница 2: ......
Страница 17: ...A 15 REVISIONS WARRANTY...
Страница 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Страница 54: ......
Страница 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Страница 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Страница 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Страница 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Страница 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Страница 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Страница 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Страница 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Страница 334: ...REVISIONS 2...
Страница 337: ......