8. CONNECTION TO YOKOGAWA TEMPERATURE CONTROLLER
8.3 Connection Diagram
8 - 13
8
CON
N
ECTION
T
O
YOKOGA
W
A
TEMPERA
T
URE C
O
NTROLLER
8.3.2
RS-485 cable
Connection diagram
(1) RS-485 connection diagram 1)
*1
Pin No. of temperature controller differs depending on the model. Refer to the following table.
*2
Terminating resistor should be provided for a temperature controller which will be a terminal.
*3
Turn on the terminating switch on the RS232C/RS485 converter at the end.
*4
Connect FG grounding to the appropriate part of a cable shield line.
(2) RS-485 connection diagram 2)
*1
Pin No. of temperature controller differs depending on the model.Refer to the following table.
*2
Terminating resistor should be provided for a temperature controller which will be a terminal.
*3
Set the terminating resistor of GOT side which will be a terminal.
■
Connecting terminating resistors
*4
Connect FG grounding to the appropriate part of a cable shield line.
Temperature
controller
RS232C/RS485
interface converter
*3
RDA(-)
RDB(+)
SDA(-)
SDB(+)
SG
1
2
3
4
5
6
RDA(-)
RDB(+)
SDA(-)
SDB(+)
SG
SDA(-)
SDB(+)
RDA(-)
RDB(+)
SG
GND
Temperature controller
Terminating resistor(220Ω 1/4W)
*2
*4
*4
*1
*1
Signal name
Model of temperature controller
GREEN Series
UT/UP/UM
GREEN Series
US
Pin No.
Pin No.
RDA (-)
26
24
RDB (+)
25
23
SDB (+)
23
21
SDA (-)
24
22
SG
27
25
Temperature
controller
SDB(+)
SDA(-)
RDB(+)
RDA(-)
SG
GND
10
12
6
8
2
14
18
16
20
1
3
4
5
7
9
11
13
15
17
19
SDB(+)
SDA(-)
RDB(+)
RDA(-)
SG
GND
RDA1(RXD1+)
RDB1(RXD1-)
SDA1(TXD1+)
SDB1(TXD1-)
SG
RSA(RTS+)
CSA(CTS+)
RSB(RTS-)
CSB(CTS-)
NC
NC
NC
SDA2(TXD2+)
SDB2(TXD2-)
RDA2(RXD2+)
RDB2(RXD2-)
NC
NC
NC
NC
Temperature controller
GOT side
*3
Terminating resistor(220Ω 1/4W)
*2
*4
*4
*1
*1
Signal name
Model of temperature controller
GREEN Series
UT/UP/UM
GREEN Series
US
Pin No.
Pin No.
SDB (+)
23
21
SDA (-)
24
22
RDB (+)
25
23
RDA (-)
26
24
SG
27
25
Содержание GOT2000Series
Страница 2: ......
Страница 17: ...A 15 REVISIONS WARRANTY...
Страница 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Страница 54: ......
Страница 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Страница 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Страница 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Страница 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Страница 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Страница 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Страница 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Страница 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Страница 334: ...REVISIONS 2...
Страница 337: ......