![Mitsubishi GOT2000Series Скачать руководство пользователя страница 148](http://html1.mh-extra.com/html/mitsubishi/got2000series/got2000series_connection-manual_1809187148.webp)
6 - 28
6. CONNECTION TO YASKAWA PLC
6.4 Device Range that Can Be Set
6.4
Device Range that Can Be Set
The device ranges of controller that can be used for GOT
are as follows.
Note that the device ranges in the following tables are the
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ
depending on the models, even though belonging to the
same series.
Please make the setting according to the specifications of
the controller actually used.
When a non-existent device or a device number outside
the range is set, other objects with correct device settings
may not be monitored.
Setting item
POINT
POINT
POINT
Device settings of YASKAWA PLC
(when using CP-9200SH, CP-9300MS, MP-920, MP-
930)
Set the coil device (MB) as follows:
(1) When setting as a bit device
Set the device using the format of word address
(DEC) + bit number (HEX).
(2) When setting as a word device
Set the device using the format of word address
(DEC).
6.4.1
YASKAWA GL/PROGIC8
*1
Change the input register "30001 to 30512" to "Z1 to Z512"
for setting. (When set in default)
*2
Change the holding register "40001 to 49999" to "W1 to
W9999" for setting. (When set in default)
*3
Change the constant register "31001 to 35096" to "K1 to
K4096" for setting. (When set in default)
(Continued to next page)
Item
Description
Device
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of
word device.
Information
Displays the device type and setting range which are
selected in [Device].
Network
Set the station number of the controller to be monitored.
Host
Select this item for monitoring the host controller.
Other
Select this for monitoring other controllers.
After selecting, set the station number of the
controller to be monitored.
NW No.: Set the network No.
Station No.: Set the station No.
Device No.
Bit position (HEX)
Word address (DEC)
Device name
Device name
Setting range
Device No.
representation
Bit
d
e
v
ice
Coil (O)
*5
O1 to O63424
Decimal
Input relay (I)
*6*7
I1 to I63424
Link coil (D)
D1 to D2048
D10001 to D12048
D20001 to D22048
Word device bit
Specified bit of the following
word devices
―
W
o
rd device
Input register (Z)
*1*7
Z1 to Z31840
Decimal
Holding register
(W)
*2*4
W1 to W28291
SW1 to SW28291
Link register
(R, SR)
*4
R1 to R2048
R10001 to R12048
R20001 to R22048
SR1 to SR2048
SR10001 to SR12048
SR20001 to SR22048
Constant register
(K)
*3
K1 to K4096
Bit device word
Converting the following bit
devices to words
Link coil
―
Device No.
Word address (DEC)
Device name
Содержание GOT2000Series
Страница 2: ......
Страница 17: ...A 15 REVISIONS WARRANTY...
Страница 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Страница 54: ......
Страница 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Страница 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Страница 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Страница 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Страница 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Страница 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Страница 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Страница 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Страница 334: ...REVISIONS 2...
Страница 337: ......