![Mitsubishi GOT2000 Series Скачать руководство пользователя страница 73](http://html.mh-extra.com/html/mitsubishi/got2000-series/got2000-series_connection-manual_1808685073.webp)
2. DEVICE RANGE THAT CAN BE SET
2.2 MELSEC-QnA, MELDAS C6 *
2 - 9
2
DEVICE RA
NGE THA
T
CAN B
E SET
2.2
MELSEC-QnA, MELDAS C6 *
The device ranges that can be set when selecting
[MELSEC-QnA/, MELDAS C6*] as the controller type are
as follows.
*1
Do not set a file register by GT Designer3 when executing
multiple programs with the file of the file register set at [Use
the same file name as the program] by the PLC parameter of
GX Developer.(Except MELSEC-QnA)
Otherwise, read/write at GOT will be erroneous.
*2
Available for file register of block No. switched with the RSET
instruction.
*3
Available for file register of block No. of file name switched
with the QDRSET instruction.
*4
Only the intelligent function module on the station connected
to GOT can be specified.
Set within the address range of the buffer memory existing in
the target intelligent function module.
*5
The device No. must be set in multiples of 16.
*6
When monitoring MELDAS C6/64, if a word device outside
the range is set, the value becomes indefinite.
When a bit device outside the range is set, the object may
not be displayed or the set function may fail to operate.
Check the set device using the device list of GT Designer3.
*7
Devices used by the MELDAS C6/64 system cannot be
used.
*8
Do not use local devices set in the MELSEC-Q system.
Otherwise, normal monitoring is not performed.
*9
This cannot be monitored when in GOT multi-drop
connection.
*10
Only reading is possible from QS001CPU.
Device name
*6*7*10
Setting range
Device No.
representation
Bit
d
e
v
ice
Input (X)
X0
to
X3FFF
Hexadecimal
Output (Y)
Y0
to
Y3FFF
Internal relay (M)
*8
M0
to
M32767
Decimal
Latch relay (L)
L0
to
L32767
Annunciator (F)
F0
to
F32767
Link relay (B)
B0
to
B7FFF
Hexadecimal
Timer
*8
Contact (TT)
TT0
to
TT32767
Decimal
Coil (TC)
TC0
to
TC32767
Counter
*8
Contact (CT)
CT0
to
CT32767
Coil (CC)
CC0
to
CC32767
Special relay (SM)
SM0
to
SM2047
Retentive
timer
*8
Contact (SS)
SS0
to
SS32767
Coil (SC)
SC0
to
SC32767
Step relay (S)
S0
to
S32767
Link special relay (SB)
SB0
to
SB7FFF
Hexadecimal
Word device bit
Specified bit of the
following word devices
(Except Timer, Counter,
Retentive timer, Index
register and Buffer
memory)
―
W
o
rd
device
Data register (D)
*8
D0
to
D32767
Decimal
Special data register (SD)
SD0
to
SD2047
Link register (W)
W0
to
W7FFF
Hexadecimal
Timer (current value) (TN)
*8
TN0
to
TN32767
Decimal
Counter (current value)
(CN)
*8
CN0
to
CN32767
Retentive timer
(current value) (SN)
*8
SN0
to
SN32767
Link special register (SW)
SW0
to
SW7FFF
Hexadecimal
File register (R)
*1*2
R0
to
R32767
Decimal
Extension
file register
(ER)
*1*9
Block
0
to
255
Device
R0
to
R32767
Extension file register
(ZR)
*1*3*9
ZR0
to
ZR1042431
Index register (Z)
Z0
to
Z15
Buffer memory
(Intelligent function module)
(G)
*4*9
G0
to
G65535
Ww
*9
Ww0
to
Ww1FFF
Hexadecimal
Wr
*9
Wr0
to
Wr1FFF
Bit device word
*5
Converting the above bit
devices into words
(Except Timer, Counter
and Retentive timer)
―
Содержание GOT2000 Series
Страница 2: ......
Страница 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 64: ......
Страница 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Страница 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Страница 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Страница 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Страница 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Страница 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Страница 416: ......
Страница 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Страница 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Страница 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Страница 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Страница 542: ......
Страница 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Страница 568: ......
Страница 592: ...19 24 19 MULTI CHANNEL FUNCTION 19 3 GOT Side Settings Example Setting example for Ethernet connection 4 channels ...
Страница 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Страница 600: ......
Страница 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Страница 670: ...REVISIONS 2 ...
Страница 673: ......