307
FX
3UC
Series Programmable Controllers
User’s Manual - Hardware Edition
9 CC-Link/LT Built-in master ability (Only FX3UC-32MT-LT)
9.17 Buffer Memory
1
O
utline
2
Exter
nal
D
im
en
sions
3
Ge
ne
ric
Speci
ficat
ions
4
Pow
er Suppl
y
Specif
icati
ons
5
Input
Spec
ific
ations
6
O
utput
Specif
icat
ions
7
Exam
pl
es
of
W
iri
ng
fo
r
Va
rious U
ses
8
Te
rm
inal B
lock
9
CC
-L
in
k/L
T
Ma
ste
r F
X
3UC
(LT
only)
10
D
ispl
ay m
odule
FX
3UC
(L
T only)
9.17
Buffer Memory
Data transfer between the PLC main unit and built-in master is executed by a program in the PLC.
9.17.1 Used instruction
1. "Built-in master
→
CPU" (Data read)
Read (transfer) the contents saved in the buffer memory (BFM) in the built-in master to a data register (D),
extension register (R) or auxiliary relay (M) for digit specification, etc. using an application instruction such as
FROM, MOV or BMOV instruction.
Example) Program to read the contents of the BFM #4 (abnormal station information) in the built-in master
(whose unit No. is fixed to 0) to D0
1) FROM instruction
2) Direct Specification of Buffer Memory (U[ ]\G[ ])
In case of the MOV instruction
Example) Program to read the contents of the BFM #0 to #3 (remote station connection information) in the
built-in master (whose unit No. is fixed to 0) to D10 to D13
1) FROM instruction
2) Direct Specification of Buffer Memory (U[ ]\G[ ])
In case of the BMOV instruction
2. "CPU
→
Built-in master" (Data write)
Write (transfer) the contents of a data register (D), extension register (R) or auxiliary relay (M) for digit
specification, constant (K or H), etc. to the buffer memory (BFM) in the built-in master using an application
instruction such as TO, MOV or BMOV instruction.
Example) Program to write "H0" to the BFM #27 (command) in the built-in master (whose unit No. is fixed to 0)
1) TO instruction
2) Direct Specification of Buffer Memory (U[ ]\G[ ])
In case of the MOV instruction
K4
D0
K1
M8000
FROM
K0
Unit
No. 0
BFM
#4
Storage
destination
Number of
transfer points
D0
M8000
MOV U0\G4
Unit No. 0
BFM #4
Storage
destination
K0
D10
K4
M0
FROMP
K0
Unit
No. 0
BFM
#0
Storage
destination
Number of
transfer points
D10
M0
BMOVP U0\G0
Unit No. 0
BFM #0
K4
Storage
destination
Number of
transfer points
K27
H0
K1
M1
TOP
K0
Unit
No. 0
BFM
#27
Transfer
source
data
Number of
transfer points
U0\G27
M1
MOVP
H0
Transfer
source
data
Unit No. 0
BFM #27