327
FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
13 High Speed Processing – FNC 50 to FNC 59
13.4 FNC 53 – HSCS / High Speed Counter Set
11
FN
C30-
FN
C39
R
o
ta
tion and
Sh
ift
12
FNC
4
0
-FNC49
D
a
ta
Op
e
ra
tio
n
13
FNC5
0
-FNC5
9
H
igh Speed
Pr
ocessi
ng
14
FM
C6
0
-F
NC6
9
H
and
y
In
st
ru
cti
o
n
15
FNC7
0
-FNC7
9
Ex
te
rn
a
l F
X
I
/O
D
evi
ce
16
FNC8
0
-FNC8
9
Ext
e
rnal
FX
D
evi
ce
17
F
N
C1
00
-F
NC
10
9
Da
ta
Tr
ansf
e
r 2
18
FN
C
110-FN
C
13
9
Fl
oat
ing P
o
in
t
19
FN
C
140-FN
C
149
Da
ta
O
per
at
io
n
2
20
FN
C
15
0-F
N
C
159
P
o
si
tioni
ng
C
ont
ro
l
13.4
FNC 53 – HSCS / High Speed Counter Set
Outline
This instruction compares a value counted by a high speed counter with a specified value, and immediately
sets an external output (Y) if the two values are equivalent each other.
→
For the counter interrupt using HSCS instruction, refer to Section 35.6.
1. Instruction format
2. Set data
3. Applicable devices
S
1: "D
.b" cannot be indexed with index registers (V and Z).
S
2: When using the counter interrupt function, specify an interrupt pointer.
→
For counter interrupt using HSCS instruction, refer to Section 35.6.
Explanation of function and operation
1. 32-bit operation (DHSCS)
When the current value of a high speed counter (C235 to C255) specified in
becomes the comparison
value [
+1,
] (for example, when the current value changes from "199" to "200" or from "201" to
"200" if the comparison value is K200), the bit device
is set to ON without regard to the operation cycle.
This instruction is executed after the counting processing in the high speed counter.
Operand Type
Description
Data Type
Data to be compared with the current data value of a high-speed counter or word
device number.
32-bit binary
Device number of a high speed counter [C235 to C255]
32-bit binary
Bit device number to be set to ON when the compared two values are equivalent
to each other
Bit
Oper-
and
Type
Bit Devices
Word Devices
Others
System User
Digit Specification
System
User
Special
Unit
Index
Constant
Real
Number
Charac-
ter String
Pointer
X
Y
M T C S D
.b KnX KnY KnM KnS T C D R U
\G
V Z Modify
K
H
E
"
"
P
3
3
3
3
3 3 3 3
3
3
3
3
3
3
3
3 3
3
S
1
3
S
2
Mnemonic
Operation Condition
32-bit Instruction
13 steps
DHSCS
Continuous
Operation
16-bit Instruction
Mnemonic
Operation Condition
−
FNC 53
HSCS
D
S
1
S
2
D
S
1
S
2
D
S
2
S
1
S
1
D
K2,147,483,647
FNC 53
DHSCS
=
→
Set to ON.
Comparison
value
Comparison
source
Output
destination
S
1
S
2
D
S
1
S
2
D
S
2
Command
input
Содержание FX3U Series
Страница 1: ...PROGRAMMING MANUAL Basic Applied Instructions Edition FX3U FX3UC SERIES PROGRAMMABLE CONTROLLERS ...
Страница 2: ......
Страница 889: ......