background image

This manual confers no industrial property rights or any rights of any other kind, 
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be 
held responsible for any problems involving industrial property rights which may 
occur as a result of using the contents noted in this manual.

Warranty

Mitsubishi will not be held liable for damage caused by factors found not to be 
the cause of Mitsubishi; opportunity loss or lost profits caused by faults in the 
Mitsubishi products; damage, secondary damage, accident compensation 
caused by special factors unpredictable by Mitsubishi; damages to products 
other than Mitsubishi products; and to other duties.

For safe use

This product has been manufactured as a general-purpose part for general 
industries, and has not been designed or manufactured to be incorporated in 
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric 
power, aerospace, medicine or passenger movement vehicles, consult with 
Mitsubishi Electric.
This product has been manufactured under strict quality control. However 
when installing the product where major accidents or losses could occur if the 
product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE

HIMEJI WORKS

 : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, 
   JAPAN
 : 840, CHIYODA CHO, HIMEJI, JAPAN

Side

B

Side

A

Side

B

JAPANESE

ENGLISH

JY997D29801B

Safety Precaution

 

(Read these precautions before use.)

This manual classifies the safety precautions into two categories: 

 and 

.

Depending on circumstances, procedures indicated by 

 may also

cause severe injury.

It is important to follow all precautions for personal safety.

Associated Manuals

Manuals for the FX

3G

 PLC will be available in September 2008 or later.

How to obtain manuals

For product manuals or documents, contact the Mitsubishi Electric dealer from

whom you purchased your product.

Certification of UL, cUL standards

FX

3U

-64CCL units comply with the UL standards (UL, cUL).

UL, cUL File Number: E95239

Regarding the standards that comply with the main unit, please refer to either

the FX series product catalog or consult with your nearest Mitsubishi product

provider.

Indicates that incorrect handling may cause hazardous

conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous

conditions, resulting in medium or slight personal injury

or physical damage.

Manual name

Manual No.

Description

FX

3G

 Series 

User’s Manual 

- Hardware Edition

JY997D31301

MODEL CODE: 

09R521

Explains the FX

3G

 Series PLC

specifications for I/O, wiring,

installation, and maintenance. 

FX

3U

 Series 

User’s Manual 

- Hardware Edition

JY997D16501

MODEL CODE: 

09R516

Explains the FX

3U

 Series PLC

specifications for I/O, wiring,

installation, and maintenance.

FX

3UC

 Series 

User’s Manual 

- Hardware Edition

JY997D28701

MODEL CODE: 

09R519

Explains the FX

3UC

 Series PLC

specifications for I/O, wiring,

installation, and maintenance.

FX

3G

/FX

3U

/FX

3UC

 Series 

Programming Manual 

- Basic & Applied 

Instruction Edition

JY997D16601

MODEL CODE: 

09R517

Describes PLC programming for

basic/applied instructions and

devices.

FX

3U

-64CCL 

User’s Manual 

JY997D30401

MODEL CODE: 

09R718

Describes FX

3U

-64CCL type

CC-Link interface block details.

Compliance with EC directive (CE Marking)

This note does not guarantee that an entire mechanical module produced in

accordance with the contents of this note will comply with the following standards.

Compliance to EMC directive and LVD directive for the entire mechanical module

should be checked by the user / manufacturer. For more information please consult

with your nearest Mitsubishi product provider.

Regarding the standards that comply with the main unit, please refer to either the FX

series product catalog or consult with your nearest Mitsubishi product provider.

Requirement for Compliance with EMC directive

The following products have shown compliance through direct testing (of the identified

standards below) and design analysis (through the creation of a technical construction

file) to the European Directive for Electromagnetic Compatibility (89/336/EEC) when

used as directed by the appropriate documentation.
Type:

Programmable Controller (Open Type Equipment)

Models:

MELSEC FX

3U

 series manufactured

from March 1st, 2008

FX

3U

-64CCL

Caution for EC Directive

Installation in Enclosure

Programmable logic controllers are open-type devices that must be installed

and used within conductive control cabinets. Please use the programmable

logic controller while installed within a conductive shielded control cabinet.

Please secure the cabinet door to the control cabinet (for conduction). Installa-

tion within a control cabinet greatly affects the safety of the system and aids in

shielding noise from the programmable logic controller.

Control cabinet

- The control cabinet must be conductive.
- Ground the control cabinet with the thickest possible grounding cable.
- To ensure that there is electric contact between the control cabinet and its door, 

connect the cabinet and its doors with thick wires. 

- In order to suppress the leakage of radio waves, the control cabinet structure 

must have minimal openings. Also, wrap the cable holes with a shielding cover 

or other shielding devices.

- The gap between the control cabinet and its door must be as small as possible 

by attaching EMI gaskets between them.

* These wires are used to improve the conductivity between the door and control

cabinet.

Configuration example inside control cabinet 

Standard

Remark

EN61131-2:2003

Programmable controllers

- Equipment

requirements and

tests

Compliance with all relevant aspects of the standard.

EMI

• Radiated Emissions

• Conducted Emissions

EMS

• Radiated electromagnetic field

• Fast Transient burst

• Electrostatic discharge

• High-energy surge

• Voltage drops and interruptions

• Conducted RF

• Power frequency magnetic field

Shielding cover

Shielded cable

Wires*

EMI gasket

Main unit

FX

3U

-64CCL

24V DC power

supply

Power

cable

Ground

cable

Ground

cable

Cable clamp

Conductive control cabinet

CC-Link dedicated cable

24+ 24-

DA DB

SLD

DG

L N

(AD75CK,

 MITSUBISHI)

Wiring simplified diagram

1. Introduction

The CC-Link interface block FX

3U

-64CCL (hereinafter called 64CCL) is a special

function block to connect the FX

3G

/FX

3U

/FX

3UC

 Series programmable logic controller

to a CC-Link network.

The 64CCL works as an intelligent device station on a CC-Link network.

Only one 64CCL unit can be connected to a single programmable logic controller main

unit.

→ 

For system configuration, refer to the FX

3U

-64CCL User's Manual.

1.1 Major Features of the FX

3U

-64CCL

1) Compatible with CC-Link Ver. 2.00 and Ver. 1.10

The 64CCL is compatible with CC-Link Ver. 2.00, and enables expanded cyclic

transmission to facilitate the handling of applications requiring multiple data

processing.

In addition to Ver. 2.00, Ver. 1.10 is also supported with the 64CCL.

1.2 Incorporated Items

Check to ensure the following product and items are included in the package:

1.3 External Dimensions and Part Names 

[1] Extension cable
[2] Direct mounting hole: 2 holes of  4.5 (0.18") (mounting screw: M4 screw)
[3] POWER LED (green)
[4] Status LEDs
[5] Name plate
[6] DIN rail mounting groove (DIN rail: DIN46277, 35mm (1.38") width)
[7] DIN rail mounting hook
[8] Power supply terminal block
[9] Extension connector
[10] CC-Link connection terminal block
[11] Number of occupied stations and expanded cyclic setting switch
[12] Transmission rate setting switch
[13] Station number setting switch

DA
DB
DG

SLD

FG

DA
DB
DG

SLD

DA
DB
DG

SLD

FG

Master

unit

FX

3U

-64CCL

CC-Link

Dedicated

Cable

(Blue)
(white)
(yellow)

CC-Link

Dedicated

Cable

Other

station

Termi-

nating

resistor

Termi-

nating

resistor

Dust proof 

protection sheet

  1

Special Unit/Block

No. label

Manual

Product

This

Manual

FX

3U

-64CCL

POWER

RUN

ERR.

RUN

ERR.

 SD

 RD

L

L

FX

3U

-64CCL

24-

24+

DA

DB

DG

SLD

STATION

NO.

COM

SETTING

B RATE STATION

10

1

X

X

0 1

2

3

45

6

7

8

9

0 1

2

3

45

6

7

8

9

012

34

5

678

9A

BC

D

EF

012

34

5

678

9A

BC

D

EF

80(3.15")

(mounting hole pitch)

55(2.17")

4(0.16")

[1]

[3]

[2]

[4]

90(3.55")

87(3.43")

[6]

9(0.36")

[10]

[8]

[9]

[11]

[12]

[7]

Without top cover

[5]

Unit: mm (inches)
MASS (Weight): 0.3kg (0.66lbs)

[13]

2-

φ

4.5 mounting holes

1.4 Power and status LEDs

1.5 Terminal layout

Terminal screw and terminal block mounting screw size, and tightening torque

Power supply terminal block, CC-Link connection terminal block: 

  M3 screw, 42 to 58 N

cm

CC-Link connection terminal block mounting screw (black): 

  M3.5 screw, 66 to 91 N

cm

CC-Link connection terminal block can be detached or attached. Make sure to cut

off all phases of the power supply externally.
For details on the wiring and the types of connection cables needed to connect to

the terminal blocks shown in the figure above, refer to the following manual.

→ 

Refer to the FX

3U

-64CCL User's Manual.

1.6 Switch setting

With regard to the switch setting for station number, transmission rate, hardware

test, number of occupied stations and expanded cyclic transmission, the switch

settings become valid after 64CCL startup.

If the switch settings are changed after 64CCL startup, the L ERR. LED will flicker.

To change the switch setting, power OFF the 64CCL once, and power it ON again.

For details on the switch setting, refer to the following manual.

→ 

Refer to the FX

3U

-64CCL User's Manual.

1.6.1

Station number setting

LED 

display

Color Status

Description

POWER Green

OFF

Power is not being supplied from the external power

supply (24V DC).

ON

Power is being supplied from the external power

supply (24V DC).

RUN

Green

OFF

64CCL has failed.

ON

Under 64CCL normal operation.

ERR.

Red

OFF

No errors.

ON

Error in the settings, error in the parameter details,

error with the communication, errors with the H/W.

L RUN

Green

OFF

Offline.

ON

Data link is being executed.

L ERR.

Red

OFF

No communication error.

Flicker

The switch setting was changed after start.

There is no terminating resistor.

Influence from noise.

ON

There is a data linking error.

There is a setting error.

SD

Green

OFF

Data is not being sent.

ON

Data is being sent.

RD

Green

OFF

Data is not being received.

ON

Data is being received.

Setting items

Range

Description

×

 10

0 to 6

1 to 64

0, 65 to 99 is the setting error.

×

 1

0 to 9

CC-Link connection

terminal block

Power supply

terminal block

24+

24-

DA

DB

SL

D

DG

1.6.2

Transmission rate setting, hardware test

1.6.3

 Number of occupied stations, expanded cyclic setting

2. Installation

Setting

Description

Status

0

Transmission rate 156Kbps

Online

1

Transmission rate 625Kbps

2

Transmission rate 2.5Mbps

3

Transmission rate 5Mbps

4

Transmission rate 10Mbps

5 to 9

Unusable

Unusable

A

Transmission rate 156Kbps

Hardware test

B

Transmission rate 625Kbps

C

Transmission rate 2.5Mbps

D

Transmission rate 5Mbps

E

Transmission rate 10Mbps

F

Unusable

Unusable

Setting

Number of occupied stations

Expanded cyclic setting

0

1 station

Single

1

2 stations

Single

2

3 stations

Single

3

4 stations

Single

4

1 station

Double

5

2 stations

Double

6

3 stations

Double

7

4 stations

Double

8

1 station

Quadruple

9

2 stations

Quadruple

A, B

Unusable

Unusable

C

1 station

Octuple

D to F

Unusable

Unusable

INSTALLATION 
PRECAUTIONS

Make sure to cut off all phases of the power supply externally before

attempting installation work.

Failure to do so may cause electric shock or damage to the product.

INSTALLATION 
PRECAUTIONS

Use the product within the generic environment specifications described in

PLC main unit manual (Hardware Edition).

Never use the product in areas with excessive dust, oily smoke, conductive

dusts, corrosive gas (salt air, Cl

2

, H

2

S, SO

2

, or NO

2

), flammable gas, vibration

or impacts, or expose it to high temperature, condensation, or rain and wind.

If the product is used in such conditions, electric shock, fire, malfunctions,

deterioration or damage may occur.

Do not touch the conductive parts of the product directly. 

Doing so may cause device failures or malfunctions.

Install the product securely using a DIN rail or mounting screws.

Install the product on a flat surface.

If the mounting surface is rough, undue force will be applied to the PC board,

thereby causing nonconformities.

When drilling screw holes or wiring, make sure that cutting and wiring debris

do not enter the ventilation slits.

Failure to do so may cause fire, equipment failures or malfunctions.

Be sure to remove the dust proof sheet from the PLC's ventilation port when

installation work is completed. 

Failure to do so may cause fire, equipment failures or malfunctions.

Make sure to attach the top cover, offered as an accessory, before turning on

the power or initiating operation after installation or wiring work. 

Failure to do so may cause electric shock.

Connect extension cables securely to their designated connectors.

Loose connections may cause malfunctions.

For details on anchoring, refer to the following manual.

→ 

Refer to the FX

3U

-64CCL User's Manual.

2.1 Connection with PLC

Only one 64CCL can be connected to the right side of a PLC main unit or extension

unit/block (including special function units/blocks). 

For connection to an FX

3UC

 Series PLC or FX

2NC

 Series PLC extension block, an

FX

2NC

-CNV-IF or FX

3UC

-1PS-5V is required. 

For further information on installation arrangements, refer to the following manuals.

→ 

Refer to the FX

3G

 Series User's Manual - Hardware Edition.

→ 

Refer to the FX

3U

 Series User's Manual - Hardware Edition.

→ 

Refer to the FX

3UC

 Series User's Manual - Hardware Edition.

2.2 Mounting

The product is mounted by the following method. 

DIN rail mounting

Direct mounting (mounting screw: M4 screw)

For further information on installation arrangements, refer to the following manuals. 

→ 

Refer to the FX

3G

 Series User's Manual - Hardware Edition.

→ 

Refer to the FX

3U

 Series User's Manual - Hardware Edition.

→ 

Refer to the FX

3UC

 Series User's Manual - Hardware Edition.

2.2.1

DIN Rail Mounting

The product can be mounted on a DIN rail (DIN46277, 35mm (1.38") width).

1) Fit the upper edge of the DIN rail mounting

groove (fig. A) onto the DIN rail. 

2) Press the product against the DIN rail. 

- An interval space of 1 to 2 mm (0.04" to 

0.08") between each unit is necessary.

2.2.2

Direct Mounting (mounting screw: M4 screw)

The product can be installed directly with screws.

Refer to the External Dimensions (section 1.3) for the product’s mounting hole pitch

information. 

An interval space between each unit of 1 to 2 mm (0.04" to 0.08") is necessary. 

3. Specification

For details on specifications, refer to the following manual.

→ 

Refer to the FX

3U

-64CCL User's Manual.

  

DESIGN
PRECAUTIONS

For the status of each station when the main unit stops calculation or when a

communication error occurs in the data link, thoroughly read the description of

data link processing time in the CC-Link master module manual. Construct an

interlock circuit in the sequence program using the communication status

information (BFM, SB, SW) so that the system always works conservatively.

Erroneous outputs and malfunctions may cause accidents.
1) Setting to hold or clear the input information against data link error

Remote outputs (RY) and remote registers (RWw) are held or cleared in

accordance with the setting of BFM #32.

   0 (default): Data prior to the error is held.

   Other than 0: Data prior to the error is cleared.

2) Setting to hold or clear the data against a stop in the main unit

Remote inputs (RX) and remote registers (RWr) are held or cleared in

accordance with the setting of BFM #33.

   0 (default): Data prior to the stop is held.

   Other than 0: Data prior to the stop is cleared.

When executing control (data changes) to an operating PLC, construct an

interlock circuit in the sequence program so that the entire system operates

conservatively. 

In addition, when executing control such as program changes and operation

status changes (status control) to an operating PLC, thoroughly read the manual

and sufficiently confirm safety in advance. 

Especially in control from external equipment to a PLC in a remote place,

problems in the PLC may not be able to be handled promptly due to abnormality

in data transfer. 

Construct an interlock circuit in the sequence program. At the same time,

determine the actions in the system between the external equipment and the PLC

(Master station contains) for protection against abnormalities in data transfer.

Make sure to include the following safety circuits outside the PLC to ensure safe

system operation even during external power supply problems or PLC failure.

Otherwise, malfunctions may cause serious accidents.
1) Above all, the following components should be included: an emergency stop

circuit, a protection circuit, an interlock circuit for opposite movements (such

as normal vs. reverse rotation), and an interlock circuit (to prevent damage to

the equipment at the upper and lower positioning limits).

2) Note that when the PLC main unit detects an error during self diagnosis, such

as a watchdog timer error, all outputs are turned off. Also, when an error that

cannot be detected by the PLC main unit occurs in an input/output control

block, output control may be disabled.

External circuits and mechanisms should be designed to ensure safe

machinery operation in such cases.

1)

2)

A

3.1 Applicable PLC

The version number can be checked by monitoring the last three digits of D8001.

*1 An FX

2NC

-CNV-IF or FX

3UC

-1PS-5V is necessary to connect the 64CCL with the

FX

3UC

 PLC.

3.2 General Specifications

Items other than the following are equivalent to those of the PLC main unit.

For general specifications, refer to the manual of the PLC main unit.

→ 

Refer to the FX

3G

 Series User's Manual - Hardware Edition.

→ 

Refer to the FX

3U

 Series User's Manual - Hardware Edition.

→ 

Refer to the FX

3UC

 Series User's Manual - Hardware Edition.

3.3 Power Supply Specification

DESIGN
PRECAUTIONS

Observe the following items. Failure to do so may cause incorrect data-writing

through noise to the PLC and result in PLC failure, machine damage or other

accident.
1) Do not bundle the control line together with or lay it close to the main circuit or

power line. As a guideline, lay the control line at least 100mm (3.94") or more

away from the main circuit or power line.

Noise may cause malfunctions.

2) Ground the shield wire or shield of a shielded cable. Do not use common

grounding with heavy electrical systems.

Do not apply excessive pressure to the power supply terminal block or CC-Link

connection terminal block. Excessive pressure may cause damage or error.

DISPOSAL 
PRECAUTIONS

Please contact a certified electronic waste disposal company for the

environmentally safe recycling and disposal of your device.

TRANSPORT AND STORAGE 
PRECAUTIONS

The PLC is a precision instrument. During transportation, avoid impacts larger

than those specified in the general specifications of the PLC main unit manual.

Failure to do so may cause failures in the PLC. 

After transportation, verify the operations of the PLC.

Model name

Applicability

FX

3G

 Series PLC

Ver. 1.00 (from the first product) and later

Only one 64CCL unit can be connected in a main unit.

FX

3U

 Series PLC

Ver. 2.20 (from the first product) and later

Only one 64CCL unit can be connected in a main unit.

FX

3UC

 Series

PLC

*1

Ver. 2.20 (from products manufactured in May, 2005 with SER

No. 55****) and later

Only one 64CCL unit can be connected in a main unit.

Item

Specification

Dielectric withstand

voltage

500V AC for one minute Conforming to JEM-1021

Between all terminals and ground

terminal

Insulation 

resistance

5M

 or more by 500V

DC megger

Item

Specification

External power

supply

Power supply voltage

24V DC +20% -15% Ripple (p-p) within 5%

P ermitted

instantaneous power

failure time

Operation continues when the 

instantaneous power failure is shorter than

PS1:1ms.

Current

consumption

220mA

3.4 Performance Specification

*1 When the setting of the 64CCL is the single setting, please set up the

master station as a Ver.1 intelligent device station. When the setting of the

64CCL are the double setting, the quadruple setting, or the octuple setting,

please set up the master station as a Ver.2 intelligent device station.

Item

Specification

CC-Link applicable version

Ver.2.00 (Ver.1.10 also supported.)

*1

Station type

Intelligent device station

Station number

1 to 64

Transmission rate

156Kbps/625Kbps/2.5Mbps/5Mbps/10Mbps

Transmission distance

In accordance with the CC-Link specification.

Refer to the PLC main unit manual for details.

Number of occupied stations

1 to 4 stations

Setting items

Station number, Transmission rate, Number of

occupied stations, Expanded cyclic setting

Connection cable

CC-Link dedicated cable/ 

CC-Link dedicated high-performance cable/ 

Ver.1.10 compatible CC-Link dedicated cable

Number of I/O occupied 

points

8 points

Number of connectable units

to the main unit

1

FX

3U

-64CCL

INSTALLATION MANUAL

This manual describes the part names, dimensions, and specifications of the

product. Before use, read this manual and manuals of relevant products fully to

acquire proficiency in handling and operating the product. Make sure to learn all

the product information, safety information, and precautions.

And, store this manual in a safe place so that you can take it out and read it

whenever necessary. Always forward it to the end user.

Registration

The company name and the product name to be described in this manual are

the registered trademarks or trademarks of each company.

Effective June 2008

Specifications are subject to change without notice.

©

 2008 Mitsubishi Electric Corporation

Manual Number

JY997D29801

Revision

B

Date

June 2008

Отзывы: