JY997D29201C

Safety Precaution

 

(Read these precautions before use.)

This manual classifies the safety precautions into two categories:

 and 

.

Depending on the circumstances, procedures indicated by 

 may

also cause severe injury.
It is important to follow all precautions for personal safety.

Associated Manuals

How to obtain manuals

For product manuals or documents, consult with the Mitsubishi Electric dealer
from who you purchased your product.

Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.

Manual name

Manual No.

Description

FX

3G

/FX

3U

/FX

3U C

Series 
User's Manual 
- Analog Control 
Edition

JY997D16701

MODEL CODE: 

09R619

Describes specifications for 
analog control and 
programming method for FX

3G

/

FX

3U

/FX

3UC

 Series PLC.

FX

3G

/FX

3U

/FX

3U C

Series 
Programming Manual 
-   B a s i c   &   A p p l i e d
Instruction Edition

JY997D16601

MODEL CODE: 

09R517

Describes PLC programming
for basic/applied instructions
and devices.

FX

3G 

Series

User’s Manual
- Hardware Edition

JY997D31301

MODEL CODE: 

09R521

Explains FX

3G

 Series PLC

specifications for I/O, wiring,
installation, and maintenance.

FX

3U

 Series 

User’s Manual 
- Hardware Edition

JY997D16501

MODEL CODE: 

09R516

Explains FX

3U

 Series PLC

specifications for I/O, wiring,
installation, and maintenance.

FX

3UC

 Series 

User’s Manual 
- Hardware Edition

JY997D28701

MODEL CODE: 

09R519

Explains FX

3UC

 Series PLC

specifications for I/O, wiring,
installation, and maintenance.

Applicable standards

FX

3U

-4AD-PNK-ADP 

units made in December, 2007 or later comply with the EC

Directive (EMC Directive) and UL standards (UL, cUL). Further information can be
found in the following manual.

→ 

FX

3G

 Series Hardware Manual (Manual No. JY997D33401)

→ 

FX

3U

 Series Hardware Manual (Manual No. JY997D18801)

→ 

FX

3UC

 (D, DSS) Series Hardware Manual (Manual No. JY997D28601)

→ 

FX

3UC

-32MT-LT-2 Hardware Manual (Manual No. JY997D31601)

Regarding the standards that relate to the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.

Attention

This product is designed for use in industrial applications.

Note

Manufactured by: Mitsubishi Electric Corporation

2-7-3 Marunouchi, Chiyoda-ku, Tokyo, 100-8310 Japan

Manufactured at: Mitsubishi Electric Corporation Himeji Works

840 Chiyoda-machi, Himeji, Hyogo, 670-8677 Japan

Authorized Representative in the European Community:

Mitsubishi Electric Europe B.V.
Gothaer Str. 8, 40880 Ratingen, Germany

Caution for EC Directive

The FX

3U

-4AD-PNK-ADP have been found to be compliant to the European

standards in the aforesaid manual and directive. However, for the very best per-
formance from what are in fact delicate measuring and controlled output device
Mitsubishi Electric would like to make the following points;
As analog devices are sensitive by nature, their use should be considered care-
fully. For users of proprietary cables (integral with sensors or actuators), these
users should follow those manufacturers installation requirements.
Mitsubishi Electric recommend that shielded cables should be used. If NO other
EMC protection is provided, then users may experience temporary loss or
accuracy between ±10% in very heavy industrial areas.
However, Mitsubishi Electric suggest that if adequate EMC precautions are fol-
lowed for the users complete control system, users should expect accuracy as
specified in this manual.

Sensitive analog cable should not be laid in the same trunking or cable
conduit as high voltage cabling. Where possible users should run analog
cables separately.

Good cable shielding should be used. When terminating the shield at Earth 
- ensure that no earth loops are accidentally created.

When reading analog values, EMC accuracy can be improved out by
averaging the readings. This can be achieved either through functions on the
analog special adapters or through a users program in the FX

3U(C)

 Series

PLC main unit.

Attach the ferrite core input cable of each channel about FX

3U

-4AD-PNK-

ADP as follows.

1. Outline

FX

3U

-4AD-PNK-ADP (hereinafter called PNK-ADP) is an analog special adapter for

measuring temperature via four channels (2-wire or 3-wire sensors) of a connected
Pt1000/Ni1000 resistance thermometer.

PNK-ADP

Shield wire

Temperature

sensor

L-

I-

L+

- For the 3-wire sensor

Ferrite core

*1

*2

*2

*2

*3

PNK-ADP

Shield wire

Temperature

sensor

L-

I-

L+

- For the 2-wire sensor

Ferrite core

*1

*2

*2

*3

*1 Use the ferrite core which has the impedance characteristic of 150

 or

more in 100MHz to 500MHz range.

*2 Wrap the cable by 2 turns.
*3 Attach the ferrite core in approximately 200mm (0.78") or less from

terminal block on the PNK-ADP side.

1.1 Incorporated Items

Verify that the following product and items are included in the package:

1.2 External Dimensions, Part Names, and Terminal Layout 

2. Installation

For installation/uninstallation details, refer to the following manuals:

→ 

FX

3G

 Series User's Manual - Hardware Edition

→ 

FX

3U

 Series User's Manual - Hardware Edition

→ 

FX

3UC

 Series User's Manual - Hardware Edition

  

2.1 Connection to the PLC

This section describes the connection method to the PLC (FX

3U

 Series PLC is used

for the following example).
For installation method to other PLCs, refer to the PLC main unit manual.

→ 

FX

3G

 Series User's Manual - Hardware Edition

→ 

FX

3UC

 Series User's Manual - Hardware Edition

Procedure

1) Turn off the power.

Disconnect all the cables connected to the PLC main unit and special adapter,
and demount the main unit and special adapter mounted on DIN rail or mounted
directly using screws.

2) Install an expansion board to the main unit.

For the expansion board installation procedure, refer to the following manual:

→ 

FX

3U

 Series User's Manual - Hardware Edition

3) Remove the special adapter connector cover

on the expansion board (fig.A).
When connecting this product to another
s p e c i a l   a d a p t e r,   p l e a s e   r e p l a c e   t h e
'expansion board' in the above description
with a 'special adapter' and perform the
procedure as indicated.

4) Slide the special adapter slide lock (fig.B) of

the main unit.
When connecting this product to another
special adapter, please replace the 'main unit'
in the above description with a 'special
adapter' and perform the procedure as
indicated.

5) Connect the special 

adapter (fig.C) to 
the main unit as 
shown on the right.

6) Slide back the 

special adapter 
slide lock (fig.B) of 
the main unit to fix 
the special adapter 
(fig.C).

Connection precautions

Connect all the high-speed I/O special adapters before connecting other spe-
cial adapters when they are used in combination.

Do not connect a high-speed I/O special adapter on the left side of any 
special adapters other than other high-speed I/O special adapters.

3. Wiring

  

Product

FX

3U

-4AD-PNK-ADP Pt1000/Ni1000 temperature sensor input

special adapter

Accessories User's manual (This manual)

[1] DIN rail mounting groove (DIN rail: DIN46277)
[2] Name plate
[3] Special adapter slide lock: 

Used to connect additional special adapters onto the left side of this special
adapter.

[4] Special adapter connector cover:

Remove this cover to connect additional special adapters to the left side.

[5] Direct mounting hole:2 holes of 

φ

4.5 (0.18") (mounting screw: M4 screw)

Not used when connecting to FX

3UC

 Series PLC.

[6] POWER LED (green):

Lit while 24V DC power is supplied properly to terminals '24+' and '24-'.

[7] Terminal block (European type):

Connect Pt1000 sensor, Ni1000 sensor and 24V DC power supply

[8] Special adapter connector:

Used to connect this special adapter to PLC main unit or special adapter.

[9] DIN rail mounting hook

[10] Special adapter fixing hook
[11] Special adapter connector:

Used to connect communication or analog special adapters to the left side of
the PNK-ADP.

INSTALLATION 
PRECAUTIONS

Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.

INSTALLATION 
PRECAUTIONS

Use the product within the generic environment specifications described in PLC
main unit manual (Hardware Edition).
Never use the product in areas with excessive dust, oily smoke, conductive
dusts, corrosive gas (salt air, Cl

2

, H

2

S, SO

2

, or NO

2

), flammable gas, vibration

or impacts, or expose it to high temperature, condensation, or rain and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.

L1+

L1-

I1-

L3+

L3-

24+

24-

L2+

L2-

L4+

L4-

I4-

I3-

I2-

FX3U-4AD-PNK

-ADP

[6]

[5]

[10]

[7]

[8]

[9]

[3]

[2]

[4]

Weight: Approx. 0.1 kg (0.22 lbs)

Special adapter 

connector cover 

is removed  

[11]

[1]

90(3.55")

98(3.86")

106(4.18")

7(0.28")

74(2.92")

15.5

(0.62")

17.6

(0.7")

15.1

(0.6")

INSTALLATION 
PRECAUTIONS

When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.

Do not touch the conductive parts of the product directly. 
Doing so may cause device failures or malfunctions.

Connect special adapter securely to their designated connectors.
Loose connections may cause malfunctions.

WIRING 
PRECAUTIONS

Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.

WIRING 
PRECAUTIONS

Make sure to cut off all phases of the power supply externally before

attempting installation or wiring work.

Failure to do so may cause electric shock or damage to the product.

RUN

STOP

FX

3U

-48MR/ES

FX

3U-48M

3)

4)

B

B

A

4)

RUN

STOP

FX

3U

-48MR/ES

-48MR/ES

FX

3U

-48M

FX

3U

-** -

**

-***

POWER

FX

3U-48M

6)

C

B

B

5)

5)

5)

6

FX

3U

-4AD-PNK-ADP

USER'S MANUAL

This manual describes the part names, dimensions, mounting, and

specifications of the product. Before use, read this manual and the manuals of

all relevant products fully to acquire proficiency in handling and operating the

product. Make sure to learn all the product information, safety information, and

precautions.

Store this manual in a safe place so that it can be taken out and read whenever

necessary. Always forward it to the end user.

Registration:

The company and product names described in this manual are registered

trademarks or the trademarks of their respective companies.

Effective September 2010
Specifications are subject to change without notice.

©

 2007 Mitsubishi Electric Corporation

Manual Number

JY997D29201

Revision

C

Date

September 2010

Отзывы: