background image

This manual confers no industrial property rights or any rights of any other kind, 
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be 
held responsible for any problems involving industrial property rights which may 
occur as a result of using the contents noted in this manual.

Warranty

Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:
(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.
(3) Special damages and secondary damages whether foreseeable or not, compensation for 

accidents, and compensation for damages to products other than Mitsubishi products.

(4) Replacement by the user, maintenance of on-site equipment, start-up test run 

and other tasks.

For safe use

This product has been manufactured as a general-purpose part for general 
industries, and has not been designed or manufactured to be incorporated in 
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric 
power, aerospace, medicine or passenger movement vehicles, consult with 
Mitsubishi Electric.
This product has been manufactured under strict quality control. However 
when installing the product where major accidents or losses could occur if the 
product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE  : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

Side

A

Side

B

JAPANESE

ENGLISH

JY997D24901E

Side

B

FX

3U

-32DP

INSTALLATION MANUAL

Before installation, operation, maintenance or inspection of this product,
thoroughly read through and understand this manual and the associated manuals.
Also, take care to handle the module properly and safely.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.

Registration
The company name and the product name to be described in this manual are the
registered trademarks or trademarks of each company.

Effective March 2018
Specifications are subject to change without notice.

 2007 Mitsubishi Electric Corporation

Manual Number JY997D24901

Revision

E

Date

March 2018

Safety Precautions

 

(Read these precautions before use.)

This manual classifies the safety precautions into two categories: 

 and 

.

Depending on circumstances, procedures indicated by 

 may also

cause severe injury.
It is important to follow all precautions for personal safety.

Associated Manuals

Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury or
physical damage.

Manual name

Manual No.

Description

FX

3G

 Series

User’s Manual
- Hardware Edition

JY997D31301

MODEL CODE:

09R521

Describes FX

3G

 Series PLC 

specification details for I/O, wiring, 
installation, and maintenance.

FX

3GC

 Series

User’s Manual
- Hardware Edition

JY997D45401

MODEL CODE:

09R533

Describes FX

3GC

 Series PLC 

specification details for I/O, wiring, 
installation, and maintenance.

FX

3U

 Series 

User’s Manual 
- Hardware Edition

JY997D16501

MODEL CODE: 

09R516

Describes FX

3U

 Series PLC 

specification details for I/O, wiring, 
installation, and maintenance.

FX

3UC

 Series

User’s Manual
- Hardware Edition

JY997D28701

MODEL CODE:

09R519

Describes FX

3UC

 Series PLC 

specification details for I/O, wiring, 
installation, and maintenance.

MELSEC iQ-F 
FX5U User's Manual 
(Hardware)

JY997D55301

MODEL CODE:

09R536

Describes FX5U CPU module 
specification details for I/O, wiring, 
installation, and maintenance.

MELSEC iQ-F 
FX5UC User's 
Manual (Hardware)

JY997D61401

MODEL CODE:

09R558

Describes FX5UC CPU module 
specification details for I/O, wiring, 
installation, and maintenance.

FX

3S

/FX

3G

/FX

3GC

/

FX

3U

/FX

3UC

 Series 

Programming 
Manual - Basic & 
Applied Instruction 
Edition

JY997D16601

MODEL CODE: 

09R517

Describes PLC programming for 
basic/applied instructions and 
devices.

MELSEC iQ-F FX5 
Programming 
Manual (Instructions, 
Standard Functions/
Function Blocks)

JY997D55801 

MODEL CODE:

09R539

Describes specications of 
instructions and functions that can 
be used in programs.

How to obtain manuals

For product manuals or documents, contact with the Mitsubishi Electric dealer you 

purchased your product.

Certification of UL, cUL standards

The following product has UL and cUL certification.

UL, cUL File Number: E95239

Regarding the standards that comply with the main unit, please refer to either the FX

series product catalog or consult with your nearest Mitsubishi product provider.

Compliance with EC directive (CE Marking)

This note does not guarantee that an entire mechanical module produced in

accordance with the contents of this note will comply with the following standards.

Compliance to EMC directive and LVD directive for the entire mechanical module

should be checked by the user / manufacturer. For more details please contact the

local Mitsubishi Electric sales site.

Requirement for the compliance with EMC directive

The following products have shown compliance through direct testing (of the identified

standards below) and design analysis (through the creation of a technical construction

file) to the European Directive for Electromagnetic Compatibility (2014/30/EU) when

used as directed by the appropriate documentation.

Attention

This product is designed for use in industrial applications.

Type:

Programmable Controller (Open Type Equipment)

Models:

MELSEC FX

3U

 series manufactured

from March 1st, 2007

FX

3U

-32DP

Cautions for compliance with EC Directive

Installation in Enclosure

Programmable controllers are open-type devices that must be installed and used

within conductive control cabinets. Please use the programmable controller while

installed within a conductive shielded control cabinet. Please secure the cabinet

door to the control cabinet (for conduction). Installation within a control cabinet

greatly affects the safety of the system and aids in shielding noise from the

programmable controller.

Control cabinet
- The control cabinet must be conductive.

- Ground the control cabinet with the thickest possible grounding cable.

- To ensure that there is electric contact between the control cabinet and its door, 

connect the cabinet and its doors with thick wires. 

- In order to suppress the leakage of radio waves, the control cabinet structure 

must have minimal openings. Also, wrap the cable holes with a shielding cover or 

other shielding devices.

- The gap between the control cabinet and its door must be as small as possible by 

attaching EMI gaskets between them.

*1 These wires are used to improve the conductivity between the door and control cabinet.

Caution for wiring

To avoid malfunctions by noise, lay the twisted-pair PROFIBUS cable so that more

than 50 mm (1.97") is touching the grounding plate connected to the ground terminal.



For details on wiring, refer to Section 3.2

Manual name

Manual No.

Description

FX

3U

-32DP 

User’s Manual

JY997D25201

Describes details for the FX

3U

-32DP 

PROFIBUS-DP Interface Block, i.e. 

wiring, installation, specification and BFM 

allocations.

FX

3U

-64DP-M 

User’s Manual

JY997D19201

Describes details for the FX

3U

-64DP-M 

PROFIBUS-DP Master Block, i.e. wiring, 

installation, specification and BFM 

allocations.

GX Configurator-DP 

Configuration 

System for Open 

Networks Software 

Manual

-

Describes the operation of GX 

Configurator-DP Configuration System 

for Open Networks Software.

Standard

Tests

EN61131-2:2007

Programmable controllers

- Equipment requirements and

tests

Compliance with all relevant aspects of the standard.

EMI

Radiated Emission

Conducted Emission

EMS

Radiated electromagnetic field

Fast transient burst

Electrostatic discharge

High-energy surge

Voltage drops and interruptions

Conducted RF

Power frequency magnetic field

Shielding cover

Shielded cable

Wires

*1

EMI gasket

1. Introduction

The FX

3U

-32DP PROFIBUS-DP Interface Block (hereinafter called 32DP) enables 

users to integrate the MELSEC FX

3G

/FX

3GC*1

/FX

3U

/FX

3UC*1

/FX5U

*2

/FX5UC

*2

 PLC 

into any existing PROFIBUS- DP network (DP-V0/DP-V1) as a DP-Slave. 
The 32DP links the FX

3G

/FX

3GC*1

/FX

3U

/FX

3UC*1

/FX5U

*2

/FX5UC

*2

 PLC with 

PROFIBUS-DP decentralized control tasks. The module connects the PLC system to 

the DP-Master in the PROFIBUS-DP network for efficient and easy data exchange.



For details, refer to FX

3U

-32DP User's Manual

*1 An FX

2NC

-CNV-IF or FX

3UC

-1PS-5V is necessary to connect to the 32DP with

the FX

3GC

/FX

3UC

 Series PLC.

However, the 32DP cannot be connected to the FX

3UC

-32MT-LT(-2).

*2 An FX5-CNV-BUS or FX5-CNV-BUSC is necessary to connect to the 32DP with

the FX5U/FX5UC PLC.

1.1 Incorporated Items

1.2 External Dimensions and Part Names

1.3 Pin configuration of PROFIBUS-DP Connector

The connector is a 9-pin D-SUB (#4-40unc inch screw thread) type, with the following

pin assignment.

Included Item

FX

3U

-32DP

1 unit

GSD file (CD-ROM)

1 piece

Special Unit/Block No. label

1 sheet

Dust proof sheet

1 sheet

Manuals (Japanese version, English version)

1 manual each

[1] PROFIBUS-DP port (9-pin D-SUB Connector: #4-40unc inch screw thread)
[2] Extension cable
[3] Direct mounting hole:2 holes of 

4.5 (0.18") (mounting screw: M4 screw)

[4] Status LED

[5] Extension port under the top cover
[6] Name plate
[7] DIN rail mounting groove (DIN rail: DIN46277)
[8] DIN rail mounting hook

43 (1.7")

9 (0.36")

90 (3.55")

80 (3.15")

4 (0.16")

2-

4.5

87 (3.43")

89 (3.51")

Dimensions: mm (inches)

MASS (Weight): Approx. 0.2 kg (0.44 lbs)

32

[7]

[8]

[5]

[6]

[3]

[4]

[2]

[1]

LED Name

Color

Description

POWER

Green

ON: Correct power supply from the PLC



For other status, refer to FX

3U

-32DP

User's Manual

FROM/TO

Green ON: Constant FROM/TO access within 200ms intervals

RUN

Green

ON: In cyclic data exchange mode
Flashing: DP-Master is in clear mode, or DP-Slave is in

Fail/Safe state.

DIA

Red

OFF: Normal Operation without errors
Otherwise: An error detected



For error details, refer to FX

3U

-32DP

User's Manual

TOKEN

Green ON: Estabilished connection with the DP-Master

Assigned

Not assigned

67

9

8

12

3

5

4

Pin No.

Signal Name

Meaning

3

RXD/TXD-P

Receive/Transmit-Data-P

4

RTS

Ready to send

5

DGND

Data Ground

6

VP

Voltage-Plus (5V, 90mA)

8

RXD/TXD-N

Receive/transmit-Data-N

1, 2, 7, 9

NC

Pin not assigned

2. Installation  

2.1 Connection with PLC

The FX

3U

-32DP connects on the right side of a PLC main unit or extension unit/

block (including special function units/blocks).
An FX

2NC

-CNV-IF or FX

3UC

-1PS-5V is necessary to connect to the 32DP with the

FX

3GC

/FX

3UC

 Series PLC. However, the 32DP cannot be connected to the

FX

3UC

-32MT-LT(-2).

An FX5-CNV-BUS or FX5-CNV-BUSC is necessary to connect to the 32DP with

the FX5U/FX5UC PLC.
For details, refer to the respective PLC manual.



FX

3G

 Series User's Manual - Hardware Edition



FX

3GC

 Series User's Manual - Hardware Edition



FX

3U

 Series User's Manual - Hardware Edition



FX

3UC

 Series User's Manual - Hardware Edition



MELSEC iQ-F FX5U User's Manual (Hardware)



MELSEC iQ-F FX5UC User's Manual (Hardware)

2.2 Mounting

The 32DP can be mounted on a DIN rail (DIN46227) or mounted directly to the
mounting surface with screws.



FX

3G

 Series User's Manual - Hardware Edition



FX

3GC

 Series User's Manual - Hardware Edition



FX

3U

 Series User's Manual - Hardware Edition



FX

3UC

 Series User's Manual - Hardware Edition



MELSEC iQ-F FX5U User's Manual (Hardware)



MELSEC iQ-F FX5UC User's Manual (Hardware)

2.2.1

Direct Mounting

The 32DP can be directly mounted with M4 screws.
An interval space of 1 to 2 mm (0.04” to 0.08”) between each unit is necessary.



For details on the mounting hole pitch, refer to Section 1.2

2.2.2

DIN Rail Mounting

The 32DP can be mounted on a DIN rail (DIN46227, 35mm width).

1) Fit the upper edge of the DIN rail mounting

groove (right fig. A) onto the DIN rail.

2) Push the product onto the DIN rail.

INSTALLATION 
PRECAUTIONS

Cut off all phases of the power supply externally before installation or wiring
work in order to avoid damage to the product or electric shock.

INSTALLATION 
PRECAUTIONS

Use the product within the generic environment specifications described in
the PLC main unit manual (Hardware Edition).
Never use the product in areas with excessive dust, oily smoke, conductive
dusts, corrosive gas (salt air, Cl

2

, H

2

S, SO

2

 or NO

2

), flammable gas,

vibration or impacts, or expose it to high temperature, condensation, or rain
and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.

Install the product securely using the DIN rail or screws.

Install the product on a flat surface. If the mounting surface is rough, undue
force will be applied to the PC board, thereby causing nonconformity.

When drilling screw holes or wiring, make sure or cutting or wire debris does
not enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.

Be sure to remove the dust proof sheet from the PLC's ventilation slits when
installation work is completed.
Failure to do so may cause fire, equipment failures or malfunctions.

Connect the extension cables and communication cables securely to the
designated connectors. Contact failures may cause malfunctions.

Do not touch the conductive parts of the product directly to avoid failure or

malfunctions.

1)

2)

A

3) Connect the 32DP’s extension cable to the 

extension port of the main unit, I/O extension 
unit/block, or special function unit/block.



FX

3G

 Series User's Manual

- Hardware Edition



FX

3GC

 Series User's Manual

 - Hardware Edition



FX

3U

 Series User's Manual

- Hardware Edition



FX

3UC

 Series User's Manual

- Hardware Edition



MELSEC iQ-F FX5U User's Manual

 (Hardware)



MELSEC iQ-F FX5UC User's Manual

  (Hardware)

3. Wiring  

3.1 Applicable Cable and Connector

The following table shows the applicable cable and connector for a PROFIBUS-
DP network.

3.2 Wiring

To connect the 32DP to a PROFIBUS-DP network, use the PROFIBUS connector
and shielded twisted-pair PROFIBUS cable complying with EN50170.

DESIGN
PRECAUTIONS

Make sure to observe the following precautions in order to prevent any
damage to the machinery or accidents due to abnormal data written to the
PLC under the influence of noise:
1) Do not bundle the main circuit line together with or lay it close to the main

circuit, high-voltage line, or load line. 
Otherwise, noise disturbance and/or surge induction are likely to take
place. As a guideline, lay the control line at least 100mm (3.94") or more
away from the main circuit, high-voltage line, or load line.

2) Ground the shield wire or shield of the shielded cable at one point on the

PLC. However, do not ground them at the same point as the high-voltage
lines.

Install module so that excessive force will not be applied to the peripheral
device connectors. Failure to do so may result in wire damage/breakage or
PLC failure.

WIRING 
PRECAUTIONS

Cut off all phases of the power supply externally before installation or wiring
work in order to avoid damage to the product or electric shock.

WIRING 
PRECAUTIONS

When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.

Item

Description

PROFIBUS-DP 
network cable

Shielded twisted-pair PROFIBUS cable complying with
EN50170

Connector

Applicable only to PROFIBUS connector
(9-pin D-SUB Connector: #4-40unc inch screw thread)



For PROFIBUS connectors see

the PROFIBUS connector manual

Shielded twisted-pair

PROFIBUS cable

complying with EN50170

to Profibus-DP network

Grounding resistance of 100 

Ω

 or less

(Class D)

For noise prevention please

attach at least 50 mm

(1.97") of the twisted-pair

PROFIBUS cable along the

grounding plate to which the ground

terminal is connected.

Shielded twisted-

pair PROFIBUS

cable to

PROFIBUS-DP

network

PROFIBUS connector

FX

3U

-32DP

PROFIBUS-DP Interface Block

Grounding plate

FX

3U

-32DP

PROFIBUS-DP

Interface Block

FX

3G

/FX

3GC

/

FX

3U

/FX

3UC

/

FX5U/FX5UC 
PLC

3.3 Grounding

Ground the cable as stated below.

Use a grounding resistor of 100

 or less.

Ground the cables indepently for best results.
When independent grounding is not used, use "shared grounding" as follows.



For details, refer to the FX

3G

 Series User's Manual - Hardware Edition.



For details, refer to the FX3

GC

 Series User's Manual - Hardware Edition.



For details, refer to the FX

3U

 Series User's Manual - Hardware Edition.



For details, refer to the FX

3UC

 Series User's Manual - Hardware Edition.



For details, refer to the MELSEC iQ-F FX5U User's Manual (Hardware).



For details, refer to the MELSEC iQ-F FX5UC User's Manual (Hardware).

The grounding wire size should be AWG 14 (2 mm

2

) or larger.

The grounding point should be as close to the PLC as possible, and all grounding
wire should be as short as possible.

3.4 Bus Terminator

To avoid the signal reflections, connect a self-terminating DP-Connector/Device at
each end of the PROFIBUS-DP Network.

Note

The FX

3U

-32DP is not self-terminated.

4. Specifications    

DESIGN
PRECAUTIONS

Make sure to have the following safety circuits outside of the PLC to ensure safe
system operation even during external power supply problems, communication
errors or PLC failure. Otherwise, malfunctions may cause serious accidents.
1) Most importantly, have the following: an emergency stop circuit, a protection

circuit, an interlock circuit for opposite movements (such as normal vs.
reverse rotation), and an interlock circuit (to prevent damage to the equipment
at the upper and lower positioning limits).

2) Note that when the PLC CPU detects an error, such as a watchdog timer

error, during self-diagnosis, all outputs are turned off.  Also, when an error that
cannot be detected by the PLC CPU occurs in an input/output control block,
output control may be disabled. External circuits and mechanisms should be
designed to ensure safe machinery operation in such a case.

3) Note that when an error occurs in a relay, triac or transistor output device, the

output could be held either on or off. For output signals that may lead to
serious accidents, external circuits and mechanisms should be designed to
ensure safe machinery operation in such a case

DESIGN
PRECAUTIONS

Make sure to observe the following precautions in order to prevent any damage to
the machinery or accidents due to abnormal data written to the PLC under the
influence of noise:
1) Do not bundle the main circuit line together with or lay it close to the main

circuit, high-voltage line, or load line.
Otherwise, noise disturbance and/or surge induction are likely to take place.
As a guideline, lay the control line at least 100mm (3.94") or more away from
the main circuit, high-voltage line, or load line.

2) Ground the shield wire or shield of the shielded cable at one point on the PLC.

However, do not ground them at the same point as the high-voltage lines.

Install module so that excessive force will not be applied to the connectors.
Failure to do so may result in wire damage/breakage or PLC failure.

STARTUP AND 
MAINTENANCE 
PRECAUTIONS

Do not touch any terminal while the PLC's power is on.
Doing so may cause electric shock or malfunctions.

Before cleaning or retightening terminals, externally cut off all phases of the power
supply. Failure to do so may cause electric shock.

Before modifying or disrupting the program in operation or running the PLC,
carefully read through this manual and the associated manuals and ensure the
safety of the operation.
An operation error may damage the machinery or cause accidents.

STARTUP AND 
MAINTENANCE 
PRECAUTIONS

Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
For repair, contact your local Mitsubishi Electric representative.

Do not drop the product or expose the product to strong impacts, as doing so may
cause product damage.

Turn off the power to the PLC before connecting or disconnecting any extension
cable.Failure to do so may cause equipment failures or malfunctions.

PLC

Other

equipment

PLC

Other

equipment

PLC

Other

equipment

Shared grounding

Good condition

Common grounding

Not allowed

Independent grounding

Best condition

4.1 Applicable PLC

*1 An FX

2NC

-CNV-IF or FX

3UC

-1PS-5V is necessary to connect to the 32DP with

the FX

3GC

/FX

3UC

 Series PLC.

However, the 32DP cannot be connected to the FX

3UC

-32MT-LT(-2).

*2 An FX5-CNV-BUS or FX5-CNV-BUSC is necessary to connect to the 32DP with

the FX5U/FX5UC PLC.

4.2 General Specifications

For the general specification, refer to the PLC main unit manual. 
The items other than the following are equivalent to those of the PLC main unit.
However, do not perform any dielectric withstand voltage tests or insulation resistance
tests on this product.



Refer to FX

3G

 Series User's Manual - Hardware Edition



Refer to FX

3GC

 Series User's Manual - Hardware Edition



Refer to FX

3U

 Series User's Manual - Hardware Edition



Refer to FX

3UC

 Series User's Manual - Hardware Edition



Refer to MELSEC iQ-F FX5U User's Manual (Hardware)



Refer to MELSEC iQ-F FX5UC User's Manual (Hardware)

4.3 Power Supply Specifications

4.4 Performance Specifications

DISPOSAL 
PRECAUTIONS

Please contact a certified electronic waste disposal company for the 
environmentally safe recycling and disposal process for your device.

TRANSPORTATION AND 
STORAGE PRECAUTIONS

The product is a precision instrument. During transportation, avoid impacts larger
than those specified in the general specifications by using dedicated packaging
boxes and shock-absorbing palettes. Failure to do so may cause failures in the
product. After transportation, verify operation of the product and check for damage
of the mounting part, etc.

Model name

Applicability

FX

3G

 Series PLC

Ver. 1.00 or later

FX

3GC

 Series PLC

*1

Ver. 1.40 or later

FX

3U

 Series PLC

Ver. 2.21 or later

FX

3UC

 Series PLC

*1

Ver. 2.21 or later

FX5U PLC

*2

From first production

FX5UC PLC

*2

From first production

Item

Specifications

Withstand 
voltage

500V AC for 1 min

Between communication 
connector frame and ground 
terminal of PLC main unit

Insulation 
resistance

5 M

 or higher by 500 V DC 

insulation resistance tester

Item

Specifications

Internal Power
Supply

145 mA at 24V DC is supplied from the internal service power in
the main unit via extension cable

Item

Specifications

Transmission Type

Bus network

Unit Type

PROFIBUS-DP Slave

Transmission Data (Maximum 
Exchanged Data Length)

• Cyclic Data : 144 Byte
• Acyclic Data : 140 Byte

Maximum Number of 
FX

3U

-32DP at one PLC

8 units

Supported 
Transmission 
speed (bps) 
and Bus 
Length

9.6k, 19.2k, 45.45k, 
93.75k

1,200 m (3,937') / segment

See Section 4.5

187.5k

1,000 m (3,281') / segment

500k

400 m (1,312') / segment

1.5 M

200 m (656') / segment

3M, 6M, 12M

100 m (328') / segment

PROFIBUS Module ID

“F332” hex

Connector

PROFIBUS-DP 
Network

PROFIBUS-DP network (9 pin D-SUB)

Global Control

Supports SYNC, UNSYNC, FREEZE, and 
UNFREEZE modes

Terminal Resistor

Not built in.

4.5 Maximum Bus Length and Baud Rate

The following table shows the acceptable bus length.
Maximum Bus Length = (No. of rep 1) * (Bus Length / segment)

「电器电子产品有害物质限制使用标识要求」的表示方式

Note: This symbol mark is for China only.

含有有害6物质的名称,含有量,含有部品
 本产品中所含有的有害 6 物质的名称,含有量,含有部品如下表

所示。

产品中有害物质的名称及含量

本表格依据SJ/T 11364的规定编制。

○:表示该有害物质在该部件所有均质材料中的含量均在GB/T 

26572规定的限量要求以下。

×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T

26572规定的限量要求。

基于中国标准法的参考规格:GB/T15969.2

Baud Rate 

(bps)

Maximum Bus Length

No repeater

1 repeater

2 repeaters

3 repeaters

9.6k, 19.2k, 
45.45k, 
93.75k

1,200 m 

(3,937')

2,400 m 

(7,874')

3,600 m 

(11,811')

4,800 m 

(15,748')

187.5k

1,000 m 

(3,281')

2,000 m 

(6,562')

3,000 

(9,843')

4,000 m 

(13,123')

500k

400 m 

(1,312')

800 m 

(2,625')

1,200 m 

(3,937')

1,600 m 

(5,249')

1.5 M

200 m (656')

400 m (1,312') 600 m (1,969') 800 m (2,625')

3M, 6M, 
12M

100 m (328')

200 m (656')

300 m (984')

400 m (1,312')