11 Buffer Memory (Parameters & Monitored Data)
11.1 Positioning Parameters
206
FX
3U
-20SSC-H Positioning Block User's Manual
11.1.2
Operation parameters 2 [BFM #14002, BFM #14202]
BFM Number
Bit
Number
Description
Default
X-axis
Y-axis
BFM #14002
BFM #14202
b0
Enables or disables the servo end check function.
→
For details on the servo end check,
refer to Subsection 7.9.2
1: Enable
At an in-position signal, is determined the positioning operation
completion
0: Disable
H0007
b1
Enables or disables the servo ready check function.
→
For details on the servo ready check,
refer to Subsection 7.9.1
1: Enable
Checks the ready signal ON/OFF at operation start / while operation
0: Disable
b2
Enables or disables the OPR interlock function.
→
For details on the OPR interlock,
refer to Subsection 7.9.10
1: Enable
D is ab le s the S T ART c om ma nd w ith out z ero r etur n c om ple tio n
Enables the START command with zero return completion (zero return
completed: ON)
0: Disable
b3
Enables or disables the ring counter setting. (Ver.1.10 or later)
→
For details on the ring couter setting,
refer to Section 7.8
1: Enables the ring operation.
0: Disables the ring operation.
b4
Set the stop method when the Stop command turns ON
(Ver.1.20 or later)
→
For details on sudden stop / Normal deceleration stop,
refer to Section 7.5
1: Sudden stop
0: Normal deceleration stop
b5
Set the stop method when the software limit turns ON
(Ver.1.20 or later)
→
For details on sudden stop / Normal deceleration stop,
refer to Section 7.5
1: Sudden stop
0: Normal deceleration stop
b6
Set the stop method when the PLC limit turns ON
(Ver.1.20 or later)
→
For details on sudden stop / Normal deceleration stop,
refer to Section 7.5
1: Sudden stop
0: Normal deceleration stop
b7
Set the stop method when the Servo amplifier stroke limit turns ON
(Ver.1.20 or later)
→
For details on sudden stop / Normal deceleration stop,
refer to Section 7.5
1: Sudden stop
0: Normal deceleration stop
b8
Set the servo ON/OFF status to be selected when the servo amplifier is started
up (in Ver. 1.30 or later).
1: Servo OFF
*1
The servo OFF status is selected when the servo amplifier is started up. It
is necessary to specify the servo ON status in a sequence program.
→
For details of the servo ON/OFF status selection at startup,
refer to Subsection 7.9.6
0: Servo ON
The servo ON status is automatically selected when the servo amplifier is
started up.
(The servo amplifier operates in the same way as versions earlier than
Ver. 1.30.)
b9 to b13
Not available