7.9 Other functions
7.9.12
System reset command (Ver.1.10 or later)
The system reset command resets the 20SSC-H system.
This command resets the system with the falling edge of the system reset command after b1 remains ON for
100 ms or more.
→
For the operation command 2, refer to Subsection 11.4.11
→
For a program example, refer to Subsection 7.1.4
How to execute the system reset command
Write the model code (K5220) to the control command enable/disable (BFM #522) before executing the
system reset command.
Note
• When the 20SSC-H version is Ver. 1.10 or later:
After changing the servo parameters stored in the flash memory, it is not necessary to turn OFF and ON
the power for transferring the servo parameters stored in the flash memory to the servo amplifier if the
system reset command is executed.
The system reset command is also convenient when using the function to transfer the servo parameters
set in the sequence program to the servo amplifier.
→
For the method to transfer the servo parameters set in the sequence program to the servo
amplifier, refer to Subsection 6.2.3, 7.1.4 and 7.1.5
• When the 20SSC-H version is earlier than Ver. 1.10:
After changing the servo parameters stored in the flash memory, it is necessary to turn OFF and ON the
power for transferring the servo parameters stored in the flash memory to the servo amplifier.
Operation
7.9.13
Servo parameter update stop (Ver.1.10 or later)
The servo parameter update stop command disables the update of the servo parameters stored in the
20SSC-H buffer memory even when the servo parameters are updated in the servo amplifier.
A sequence program can change the servo parameters stored in the buffer memory in the 20SSC-H and write
updated values to the flash memory while the servo parameter update stop command is ON.
→
For the operation command 2, refer to Subsection 11.4.11
→
For a program example, refer to Subsection 7.1.6
Note
The 20SSC-H does not update the servo parameters stored in the buffer memory while the servo parameter
update stop command is ON.
After transferring servo parameters to the servo amplifier, set this command to OFF as necessary to restart
automatic update of servo parameters.
BFM Number
Description
X-axis
Y-axis
System reset
command
Operation
command 2
BFM #519 b1
Set this bit to ON (keep it ON for 100 ms or more), and then set it to OFF in
a sequence program.
BFM Number
Description
X-axis
Y-axis
Control command enable/disable
BFM #522
Write K5220 in a sequence program.
BFM Number
Description
X-axis
Y-axis
Servo parameter update
stop
Operation
command 2
BFM #519
b11
BFM #619
b11
1 (ON):
Does not update servo parameters even if the servo
amplifier sends the servo parameter update request.
0 (OFF): Transfers servo parameters to the buffer memory (for
update) when the servo amplifier sends the servo
parameter update request.
Operation command 2
BFM#519 b1
100ms or more
Executes system reset.
OFF