10.2.12 Model code [BFM #30 (1Eh)]
The model code (K7120) of the FX
2N
-64CL-M is stored here.
10.2.13 Detailed remote station information [BFM #32 (20h) to #95 (5Fh)]
The information (I/O type, number of points) on remote stations is stored here.
In the CONFIG mode, the contents of these buffers can be changed.
(For the details on content changes, refer to "8.4 Specification of reserved station" and "8.5
Editing the detailed remote station information".)
Buffer memory assignment
Configuration of detailed remote station information
Details of each item of detailed remote station information
1) Number of I/O points (b4 to b0)
The number of I/O points used in each station number assigned to each buffer memory is
stored here.
The maximum number of points is 4 or 16 in accordance with the number of points per
station set by the DIP switch for operation setting.
When a remote I/O unit with 16 I/O points is used in the 4-point mode, the number of points
per buffer memory is 4, and the I/O points of the remote I/O unit are assigned to four buffer
memories.
In the case of a composite I/O unit, the larger one between the number of input points and
the number of output points is stored here.
In the case of remote device station, 16 points are stored here.
Buffer memory No.
Description
BFM #32 (20h)
Remote station information area for the station No.1
BFM #33 (21h)
Remote station information area for the station No.2
...
...
BFM #95 (5Fh)
Remote station information area for the station No.64
Bit
Function
1(ON)
0(OFF)
b0
Number of I/O points
00001:1point
00101:5points
01001: 9points
01101:13points
00010:2points
00110:6points
01010:10points
01110:14points
00011:3points
00111:7points
01011:11points
01111:15points
00100:4points
01000:8points
01100:12points
10000:16points
The bits above are in the order "b4, b3, b2, b1, b0".
b1
b2
b3
b4
b5 to b7
(Setting prohibited)
Set these bits to 0.
b8
Input flag
Input is given.
Input is not given.
b9
Output flag
Output is given.
Output is not given.
b10
RD station flag
It is RD station.
It is not RD station.
b11
Head station flag
This is the head station.
This is not the head station.
b12
Input filter setting
High-speed input
General-purpose input
b13
Output hold/clear setting
HOLD
CLEAR
b14
(Setting prohibited)
Set these bits to 0.
b15
Reserved station flag
This is specified as reserved
station.
This is not specified as
reserved station.
Содержание FX2N-64CL-M
Страница 1: ...USER S MANUAL Detailed Volume FX2N 64CL M CC Link LT Master Block ...
Страница 4: ...FX2N 64CL M CC Link LT Master Block ii ...
Страница 6: ...FX2N 64CL M CC Link LT Master Block iv ...
Страница 12: ...FX2N 64CL M CC Link LT Master Block x ...
Страница 26: ...FX2N 64CL M CC Link LT Master Block System Startup Procedure 3 3 2 ...
Страница 48: ...FX2N 64CL M CC Link LT Master Block Connection of Cables Connectors and Terminating Resistors 6 6 10 ...
Страница 50: ...FX2N 64CL M CC Link LT Master Block Various Modes 7 7 2 ...
Страница 74: ...FX2N 64CL M CC Link LT Master Block Model Assignment of Buffer Memory 10 10 14 ...
Страница 93: ......