3 Introduction of Products (Compliant with Overseas Standards)
3.1 List of Products (to be Connected) and Interpretation of Model Names
3.1.1
[A] Main units
The main unit incorporates a CPU, memory, input and output terminals and power supply.
To establish a system, at least one main unit is necessary.
: Compliance with standard or self-declaration : Not targeted
−
: Not applicable
* Please consult with Mitsubishi Electric for information on marine standard practices and the
corresponding types of equipment.
→
For more information on CE, UL and cUL, refer to Page 15 or later.
Number of input/output points
Model name
Output type
(connection form:
terminal block)
CE
UL
cUL
Marine
Total
number of
points
Number of
input
points
Number of
output
points
EMC
LVD
AC power supply common to 24V DC sink and source input
16
8
8
FX
3U
-16MR/ES
Relay
*
16
8
8
FX
3U
-16MT/ES
Transistor (sink)
*
16
8
8
FX
3U
-16MT/ESS
Transistor (source)
*
32
16
16
FX
3U
-32MR/ES
Relay
*
32
16
16
FX
3U
-32MT/ES
Transistor (sink)
*
32
16
16
FX
3U
-32MT/ESS
Transistor (source)
*
32
16
16
FX
3U
-32MS/ES
Triac
*
48
24
24
FX
3U
-48MR/ES
Relay
*
48
24
24
FX
3U
-48MT/ES
Transistor (sink)
*
48
24
24
FX
3U
-48MT/ESS
Transistor (source)
*
64
32
32
FX
3U
-64MR/ES
Relay
*
64
32
32
FX
3U
-64MT/ES
Transistor (sink)
*
64
32
32
FX
3U
-64MT/ESS
Transistor (source)
*
64
32
32
FX
3U
-64MS/ES
Triac
*
80
40
40
FX
3U
-80MR/ES
Relay
*
80
40
40
FX
3U
-80MT/ES
Transistor (sink)
*
80
40
40
FX
3U
-80MT/ESS
Transistor (source)
*
128
64
64
FX
3U
-128MR/ES
Relay
*
128
64
64
FX
3U
-128MT/ES
Transistor (sink)
*
128
64
64
FX
3U
-128MT/ESS
Transistor (source)
*
DC power supply common to 24V DC sink and source input
16
8
8
FX
3U
-16MR/DS
Relay
*
16
8
8
FX
3U
-16MT/DS
Transistor (sink)
*
16
8
8
FX
3U
-16MT/DSS
Transistor (source)
*
32
16
16
FX
3U
-32MR/DS
Relay
*
32
16
16
FX
3U
-32MT/DS
Transistor (sink)
*
32
16
16
FX
3U
-32MT/DSS
Transistor (source)
*
48
24
24
FX
3U
-48MR/DS
Relay
*
48
24
24
FX
3U
-48MT/DS
Transistor (sink)
*
48
24
24
FX
3U
-48MT/DSS
Transistor (source)
*
64
32
32
FX
3U
-64MR/DS
Relay
*
64
32
32
FX
3U
-64MT/DS
Transistor (sink)
*
64
32
32
FX
3U
-64MT/DSS
Transistor (source)
*
80
40
40
FX
3U
-80MR/DS
Relay
*
80
40
40
FX
3U
-80MT/DS
Transistor (sink)
*
80
40
40
FX
3U
-80MT/DSS
Transistor (source)
*
A
•
•
•
•
•
•
•
•
FX
3U
M
Incorporating power supply, CPU, memory and input/output
Power supply Input/output type: Connection on terminal block
R/ES : AC power supply/24V DC (sink/source) input/relay output
T/ES : AC power supply/24V DC (sink/source) input/transistor (sink) output
T/ESS: AC power supply/24V DC (sink/source) input/transistor (source) output
R/DS : DC power supply/24V DC (sink/source) input/relay output
T/DS : DC power supply/24V DC (sink/source) input/transistor (sink) output
T/DSS: DC power supply/24V DC (sink/source) input/transistor (source) output
Series name
Main unit
Total number of input
and output points
S/ES : AC power supply/24V DC (sink/source) input/triac (SSR) output
R/UA1: AC power supply/100V AC input/relay output
Содержание FX2-16E series
Страница 2: ......
Страница 8: ... 6 Safety Precautions Read these precautions before use MEMO ...
Страница 508: ...FX3U Series Programmable Controllers User s Manual Hardware Edition 500 C Character code C 1 ASCII Code Table MEMO ...
Страница 510: ...502 FX3U Series Programmable Controllers User s Manual Hardware Edition D Discontinued models MEMO ...
Страница 519: ......