5.1.8 Alarm History (Inverter) (B-12300)
Outline
This screen is used to confirm the fault (failure) currently occurring and the alarm history of the inverter
connected to the GOT.
Description
1.
Displays the fault (failure) currently occurring.
2.
Displays the alarm history of the latest eighth faults (failure).
3.
Switches to [Manual Display] screen.
(Displayed manual: "2. Protective Functions" of "INVERTER FR-E800 Instruction Manual
(Maintenance)").
4.
Executes the inverter reset. (Operates when holding down the switch for 3 seconds).
Use this switch when performing the inverter reset after completing dealing with the fault (failure)
currently occurring.
5.
Executes the all clear of the alarm history. (Operates when holding down the switch for 3 seconds).
Remarks
・
The system alarm "401 An error response has been received from the connected device" occurs when
connecting the GOT to the inverter via PLC with CC-Link IE TSN and executing the inverter reset.
Therefore display [Alarm History (Inverter)] screen again after the communication with the inverter recovers
to restart the monitoring.