![Mitsubishi FR-A846-00023 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/mitsubishi/fr-a846-00023/fr-a846-00023_instruction-manual_1809256048.webp)
Operation panel (FR-DU08-01)
47
2
2.7.3
Basic operation of the operation panel
For the details of each function, refer to the FR-A800 Instruction Manual (Detailed).
The USB memory mode will appear if a USB memory device is connected. (Refer to
Operation mode switchover/Frequency setting
Function
Monitor
Parameter setting
Faults history
Flickering
Flickering
Flickering
External operation mode
(
At power-ON)
Parameter setting mode
(
At power-ON
)
PU operation mode
PU Jog operation mode
Output current monitor
Output voltage monitor
Value change
(Example)
Frequency setting has been
written and completed!!
Flicker
[Operation for displaying faults history]
Past eight faults can be displayed.
(The latest fault is ended by ".".)
Parameter setting mode
Function mode
Display the present
setting
Value change
Parameter write is completed!!
Flicker
(Example)
(Example)
(Example)
(Example)
Parameter copy
Initial value change list
IPM parameter initialization
Parameter clear
All parameter clear
Faults history clear
Automatic parameter setting
Trace function
∗1
Faults history 1
Faults history 2
Faults history 8
When no fault history exists, is displayed.
Group parameter setting
Long press