Mitsubishi CL1XY2-DTE1D5S Скачать руководство пользователя страница 1

Warranty

Mitsubishi will not be held liable for damage caused by factors found not to be the
cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi
products; damage, secondary damage, accident compensation caused by special
factors unpredictable by Mitsubishi; damages to products other than Mitsubishi
products; and to other duties.

For safe use

• This product has been manufactured as a general-purpose part for general 

industries, and has not been designed or manufactured to be incorporated in a 
device or system used in purposes related to human life.

• Before using the product for special purposes such as nuclear power, electric power, 

aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.

• This product has been manufactured under strict quality control. However when 

installing the product where major accidents or losses could occur if the product 
fails, install appropriate backup or failsafe functions in the system.

Country/Region Sates office/Tel
U.S.A

Mitsubishi Electric Automation Inc.
500 Corporate Woods Parkway Vernon
Hills, IL 60061
Tel : +1-847-478-2100

Brazil

MELCO-TEC Rep. Com.e Assessoria
Tecnica Ltda.
Av. Rio Branco, 123-15 ,and S/1507,
Rio de Janeiro, RJ CEP 20040-005,
Brazil
Tel : +55-21-221-8343

Germany

Mitsubishi Electric Europe B.V. German
Branch
Gothaer Strasse 8 D-40880 Ratingen,
GERMANY
Tel : +49-2102-486-0

U.K

Mitsubishi Electric Europe B.V. UK
Branch
Travellers Lane, Hatfield, Herts., AL10
8XB, UK
Tel : +44-1707-276100

Italy

Mitsubishi Electric Europe B.V. Italian
Branch
Centro Dir. Colleoni, Pal. Perseo - Ingr.2
Via Paracelso 12, 20041 Agrate B.,
Milano, Italy
Tel:+39-039-60531

Spain

Mitsubishi Electric Europe B.V. Spanish
BranchCarretera de Rubi 76-80
08190 - Sant Cugat del Valles,
Barcelona, Spain
Tel:+34-935-653135

South Africa Circuit Breaker Industries LTD.

Private Bag 2016, Isando 1600,
Johannesburg, South Africa
Tel : +27-11-928-2000

Hong Kong Ryoden Automation Ltd.

10th Floor, Manulife Tower, 169 Electric
Road, North Point, HongKong
Tel : +852-2887-8870

Specifications are subject to change without notice

HEAD OFFICE

:

MITSUBISHI DENKI BLDG MARUNOUTI TOKYO 100-8310

TELEX:J24532 CABLE MELCO TOKYO

HIMEJI WORKS

:

840, CHIYODA CHO, HIMEJI, JAPAN

When exported from Japan, this manual does not require application to the Ministry of Economy,
Trade and Industry for service transaction permission.

Country/Region Sates office/Tel
China

Ryoden International Shanghai Ltd.
3F Block5 Building Automation
Instrumentation Plaza 103 Cao Bao Rd.
Shanghai 200233 China
Tel : +86-21-6475-3228

Taiwan

Setsuyo Enterprise Co., Ltd.
6F., No.105 Wu-Kung 3rd.RD, Wu-Ku
Hsiang, Taipei Hsine, Taiwan
Tel : +886-2-2299-2499

Korea

HAN NEUNG TECHNO CO.,LTD.
1F Dong Seo Game Channel Bldg.,
660-11, Deungchon-dong Kangsec-ku,
Seoul, Korea
Tel : +82-2-3660-9552

Singapore Mitsubishi Electric Asia Pte, Ltd.

307 ALEXANDRA ROAD #05-01/02,
MITSUBISHI ELECTRIC BUILDING
SINGAPORE159943
Tel : +65-473-2480

Thailand

F. A. Tech Co.,Ltd.
898/28,29,30 S.V.City Building,Office
Tower 2,Floor 17-18 Rama 3 Road,
Bangkpongpang, Yannawa,
Bangkok 10120
Tel : +66-2-682-6522

Indonesia

P.T. Autoteknindo SUMBER MAKMUR
Jl. Muara Karang Selatan BlockA Utara
No.1 Kav. No.11 KawasanIndustri/
PergudanganJakarta - Utara 14440
Tel : +62-21-663-0833

India

Messung Systems Put,Ltd.
Electronic Sadan NO:111 Unit No15,
M.I.D.C BHOSARI,PUNE-411026
Tel : +91-20-7128927

Australia

Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, PostalBag, No 2,
Rydalmere, N.S.W 2116, Australia
Tel : +61-2-9684-7777

Side

A

Side

B

JAPANESE

ENGLISH

Side

B

SAFETY PRECAUTIONS

(Read these precautions before using)

Please read this manual carefully and pay special attention to safely in order
to handle this product properly. Also pay careful attention to safely and handle
the module properly.
These precautions apply only to Mitsubishi equipment. Refer to the user’s
manual of the CPU module to use for a description of the PLC system safety
precautions.
These 

SAFETY PRECAUTIONS

 classify the safety precautions into two

categories: "DANGER" and "CAUTION".

Depending on circumstances, procedures indicated by 
may also be linked to serious results.
In any case, it is important to follow the directions for usage.
Store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.

[DESIGN PRECAUTIONS] 

[INSTALLATION PRECAUTIONS]

[WIRING PRECAUTIONS] 

Procedures which may lead to a dangerous condition 
and cause death or serious injury if not carried out 
properly.

Procedures which may lead to a dangerous condition 
and cause superficial to medium injury, or physical 
damage only, if not carried out properly.

DANGER

CAUTION

CAUTION

• Configure an interlock circuit in a sequence program so that the system 

operates on the safety side using the communication status information 
in the event the data link falls into a communication problem.
Otherwise, erroneous output and malfunction may result in accidents.

• Remote input and output can not be switched ON or OFF when a 

problem occurs in the remote I/O modules. Therefore build an external 
monitoring circuit that will monitor any input signals that could cause a 
serious accident.

• Do not have control cables and communication cables bundled with or 

placed near by the main circuit and/or power cables. Wire those cables 
at least 100mm(3.94 inch) away from the main circuit and/or power 
cables. It may cause malfunction due to noise interference.

• Use the module in the status in which any force is not applied on the 

module, flat cables dedicated to CC-Link/LT and flat cables for I/O.
If a force is applied, wire breakage or failure may be caused.

DANGER

CAUTION

• Use the module in an environment that meets the general specifications 

contained in this manual. Using this module in an environment outside 
the range of the general specifications could result in electric shock, fire, 
erroneous operation, and damage to or deterioration of the product.

• Do not directly touch the module's conductive parts.Doing so could 

cause malfunction or trouble in the module.

CAUTION

• Perform installation and wiring after disconnecting the power supply at 

all phases externally. If the power is not disconnected at all phases an 
electric shock or product damage may result.

DANGER

[STARTING AND MAINTENANCE PRECAUTIONS] 

[DISPOSAL PRECAUTIONS] 

[TRANSPORTATION AND MAINTENANCE PRECAUTIONS] 

Notification of CE marking

This notification does not guarantee that an entire mechanical module produced
in accordance with the contents of the notification comply with the following
standards. Compliance to EMC standards of the entire mechanical module
should be checked by the user / manufacturer.

Standards with which this product complies

Type : Programmable Controller (Open Type Equipment) Remote I/O module
Models : Products manufactured from November 1st, 2002.

For more details please contact the local Mitsubishi Electric sales site.
- Notes For compliance to EMC regulation.
It is necessary to install the CL1 series module in a shielded metal control panel.

• Perform correct wiring for the module according to the product’s rated voltage 

and terminal arrangement. Connecting to a power supply different from rating 
or miss-wiring may cause fire, product failure or malfunction.

• Make sure foreign objects do not get inside the module, such as dirt and wire 

chips. It may cause fire, product failure or malfunction.

• Attach a warning label (hazard symbol 417-IEC-5036) concerning the electric 

shock to the location.

• Do not touch the terminals when the power is ON. It may cause an electric 

shock or malfunction.

• Perform cleaning the module after turning OFF the all external power supply 

for sure. Failure to do so may cause failure or malfunction of the modules.

• Do not disassemble or modify the module. Doing so may cause failure, 

malfunction, injury, or fire.

• The module case is made of resin; do not drop it or subject it to strong shock. 

A module damage may result.

• Make sure to switch all phases of the external power supply OFF before 

installing or removing the module to/from the panel. Failure to do so may 
cause failure or malfunction of the modules.

CAUTION

DANGER

CAUTION

• When disposing of this product, treat it as industrial waste.

• During transportation avoid any impact as the module is a precision 

instrument. Doing so could cause trouble in the module.

• If is necessary to check the operation of module after transportation, in case 

of any impact damage.

Electromagnetic Compatibility Standards

(EMC)

Remark

EN61000-6-4:2001

Electromagnetic compatibility
-Generic standards - Emission standard for
  Industrial environment

Compliance with all relevant 
aspects of the standard. (Radiated 
Emissions and Mains Terminal 
Voltage Emissions)

EN61131-2:1994 Programmable controllers

/A11: 1996 -Equipment requirements and 

tests

/A12: 2000

Compliance with all relevant 
aspects of the standard. (RF 
Immunity, Fast transients, ESD and 
Damped oscillatory wave)

DANGER

CAUTION

1.

Outline of Product

This product is a cable type composite I/O module connected to CC-Link/LT. 
This product has one input point (24V DC) and one output point (transistor
output).

2.

Name and Setting of Each Part

Sensor

Connector dedicated
to CC-Link/LT
(sold separately)

Switches

Input/output is ON: Lit
Input/output is OFF: Extinguished

Attach it with

this area facing

upward.

Status indicator LEDs

LED name
PW

L RUN

Operation
Lit while the
power is supplied.
Lit while normal
operation is
executed.

Blue

40 20

 

10

 

 

 

4   2   1

HLD

DIP switch

(Remove the switch cover

when setting the DIP switch.)

DIP switch assignment

Switch cover

(Make sure to attach the

switch cover after setting

the DIP switch.)

Input

operation

indicator

LED

Output

operation

indicator

LED

Flat cable dedicated

to CC-Link/LT

Flat cable for I/O

ON

Black

White

Brown

Name

Description

Status indicator 
LED

PW

ON while the power is supplied.

L RUN

ON while normal operation is executed.

I/O operation 
indicator LED

ON while the input or output is ON.
Extinguished while the input or output is OFF.

Flat cable 
dedicated to CC-
Link/LT

24G

Connector for CC-Link/LT communication line/
module power supply

DB

DA

+24V

Flat cable for I/O

Blue

24G

Black

X0

White

Y0

Brown

+24V

DIP switch

Set the 10's digit of the station No. using "STATION NO. 10", 
"STATION NO. 20" and "STATION NO. 40". Set the 1's digit of 
the station No. using "STATION NO. 1", "STATION NO. 2", 
"STATION NO. 4" and "STATION NO. 8".
Factory default = All bits are OFF.
Make sure to set the station No. in the range from 1 to 64.

X0 input operation

indicator LED

Y0 output operation

indicator LED

0

0

40

20

10

8

4

2

1

10's digit

1's digit

Station

No.

32

ON

OFF

ON

OFF

ON

OFF

OFF

Example: When setting the station No. to "32", set the
                DIP switch as follows.

3.

Cautions on Handling

3.1 Handling of flat cable for I/O

The cable length from the module to a sensor shall be within 3m(9'10").
Measure the cable outside the module, and confirm that the driving voltage
for the used sensor is assured.

• Input

• Output

If the diameter of the I/O equipment connection cable is equivalent to the
diameter of the flat cable for I/O of this module, connectors dedicated to
CC-Link/LT can be used for connection.

3.2 Handling of cable

Do not bend the cable within 30mm(1.19") from the module.

Use a crimp-style terminal in a status in which no force is applied on the
cable.

Name

Description

DIP switch

HLD

Holds the output (when an error has occurred).
ON: Holds the output.
OFF: Clears the output.

Crimp-style connection device with
insulator or closed end connection 
device

Sensor,
switch, etc.

Crimp-style connection device with
insulator or closed end connection 
device

Lamp,
solenoid, etc.

Input
equipment

Connector dedicated to CC-Link/LT

Output
equipment

Wire diameter: AWG18 (34/0.18)

30mm(1.19")

30mm(1.19")

4.

Connection to External Equipment

4.1 External wiring

The input and output terminals of the CL1XY2-DTE1D5S operate while
using the power supplied from the interface.
When connecting a sensor to the input terminal, use a sensor of the PNP
open collector transistor type.
The output wiring is fixed to the sink output.

I/O wiring

4.2 Connection to sensor

• When using a two-wire type sensor

!

When using a three-wire type sensor 

Replace * in the figure with the used input No.

Notes:

*1 Bleeder resistor

When connecting a two-wire type sensor or input equipment containing a
parallel resistor, select a sensor or equipment whose leakage current is
1.7mA or less.
If the leakage current is more than 1.7mA, connect a bleeder resistor
obtained in the following calculation formula.

Circuit image

R(k

) < 1.7(mA) / Leakage current(mA) - 1.7(mA) x 5.6(k

)

The power capacity W of the bleeder resistor R is as follows:
W = (Input voltage)

2

/R

• Make sure that both the ON and OFF time of the input signal are 1.5ms or 

more.

0.5A

0.5A

24G

DA
DB

+24V

DC DC

Isolation

Flat cable
dedicated
to CC-Link/LT

Y0

X0

+24V

24G

Flat cable
for I/O

Internal
circuit

R

R

R

CL1XY2-DTE1D5S

L

Detection
circuit

Sensor (PNP)

Sensor (PNP)

Bleeder 

resistor *1

Connected to 24G cable

Connected to 24G cable

X  *

+24

X  *

+24

Detection
circuit

R

24V DC

Leakage
current

Input impedance
5.6 k

1.7 mA or less

R: Bleeder resistor

Sensor(PNP)

Unit

Detection
circuit

5.

Specifications

5.1 General specifications

Notes:

*1 The ambient operating/storage temperature satisfies the requirements beyond

the specification in the JIS B3502 and the IEC61131-2.

*2 The module cannot be used in an environment pressurized above the

atmospheric pressure which can be generated around the altitude of 0 m. If the
module is used in such an environment, it may fail.

*3 The module can be used in any environment even outside the control panel as

far as the requirements of the ambient operating temperature, the ambient
operating humidity, etc. are satisfied.

*4 This indicates the section of the power supply to which the equipment is

assumed to be connected between the public electrical power distribution
network and the machinery within premises. Category 

II

 applies to equipment

for which electrical power is supplied from fixed facilities.
The surge voltage withstand level for up to the rated voltage of 300V is 2500V.

*5 This index indicates the degree of conductive generating substances in the

environment in which the module is used. The degree of contamination 2
indicates that contamination is caused by generation of only non-conductive
substances.
In this degree, however, temporary conduction may be caused by accidental
condensation.

5.2 Input specifications

Item

Specification

Ambient 
working 
temperature

0 to 55

°

C (32 to 131

°

F) (*1)

Ambient storage 
temperature

-25 to 75

°

C (-13 to 167

°

F) (*1)

Ambient 
operating 
humidity

Conforming to JIS B3502 and IEC61131-2, Level RH-2
(5 to 95%RH: Dew condensation shall not be considered.)

Ambient storage 
humidity

Conforming to JIS B3502 and IEC61131-2, Level RH-2
(5 to 95%RH: Dew condensation shall not be considered.)

Vibration 
resistance

Conforming 
to JIS 
B3502 and 
IEC61131-2

When intermittent vibration is present

Number of 
times of 
sweep

Frequency Acceleration Half amplitude

10 times 
in each of 
X, Y and Z 
directions 
(for 80 
min)

10 to 57Hz

0.075mm

57 to 150Hz 9.8m/s

2

When continuous vibration is present

Frequency Acceleration Half amplitude

10 to 57Hz

0.035mm

57 to 150Hz 4.9m/s

2

Impact 
resistance

Conforming to JIS B3502 and IEC61131-2
(147 m/s

2

, 3 times in each of X, Y and Z directions)

Operating 
atmosphere

Corrosive gas shall not be present.

Operating 
altitude

Conforming to JIS B3502 and IEC61131-2
(2,000m(6561'8") or less)(*2)

Installation 
place

Inside control panel (*3)

Over-voltage 
category

Conforming to JIS B3502 and IEC61131-2
(Category 

ΙΙ

 or less)(*4)

Degree of 
contamination

Conforming to JIS B3502 and IEC61131-2, Degree of 
contamination 2 or less (*5)

Item

Specification

Input method

DC input (using module power supply in common)
EN61131-2, Section3.3.1.2-Type1

Number of input

1 point

Isolation method

Isolation with photocoupler

Rated input voltage

24V DC

Rated input current

Approx. 4 mA

Operating voltage range

Same as module power supply

Max. simultaneous ON 
input points

100% (at 24V DC)

ON voltage/ON current

19 V or more/3 mA or more

OFF voltage/OFF current

11 V or less/1.7 mA or less

Input resistance

5.6 k

Response 
time

OFF

ON

1.5 ms or less (at 24V DC)

ON

OFF

1.5 ms or less (at 24V DC)

Common wiring method

1 point/1 common (Mutually exclusive output)

5.3 Output specifications

5.4 Performance specifications

Item

Specification

Output method

Transistor output
(using module power supply in common) (source)

Number of output

1 point

Isolation method

Isolation with photocoupler

Rated load voltage

24V DC

Operating load voltage 
range

Same as module power supply

Max. load current

0.1A/point    0.2 A/1 common

Max. inrush current

0.4A/10 ms

Leakage current at OFF

0.1mA or less/30V DC

Max. voltage drop at ON

1V or less (max.)/0.1A

Response 
time

OFF

ON

1.0ms or less

ON

OFF

1.0ms or less 

Surge suppression

Zener diode

Common wiring method

1 point/1 common (Mutually exclusive output)

Internal protection for 
outputs

Internal protection circuit none
Please connect the fuse in the connected load 
outside.

Item

Specification

Module 
power 
supply

Voltage

20.4 to 28.8V DC (24V DC -15% to +20%)
Ripple ratio: Within 5% 

Current 

consumption

40mA (when all points are ON)
(Current consumption contains neither the input 
current nor the load current.)

Initial current

70mA

Max. allowable 

momentary power 

failure period

PS1:1ms

Number of stations 
occupied

4-, 8- or 16-point mode: 1 station

Noise durability

500Vp-p
Noise width: 1

µ

s Cycle: 25 to 60 Hz

(by noise simulator)

Withstand voltage

500V AC for 1 min

Isolation resistance

10 M

 or more between primary area (external 

DC terminal) and secondary area (internal circuit) 
by 500V DC megger

Protection class

IP2X

I/O part connection method

Connection with cable

Module installation method

Can be installed in six directions

Flat cable for I/O (wire 
diameter)

AWG18 (34/0.18)

Mass (weight)

0.07 kg (0.15 lbs)
(including 500mm (19.69") flat cable dedicated to 
CC-Link/LT and 500mm (19.69") flat cable for I/O)

6.

Outside Dimensions

Unit: mm(inches)

24G       X0         Y0 

      

 +24V

20(0.79")

65(2.56")

500(19.69")

12(0.48")

500(19.69")

CL1XY2-DTE1D5S

CC-Link/LT Remote I/O Module

Please read this manual thoroughly before starting to use the product and 
handle the product properly.

User’s Manual

MODEL

 CL1XY2-DTE1D5S

MANUAL Number

 JY997D06301A

Date

 NOVEMBER 2002