APP -
25
APPENDICES
*:
Usable with AnN and AnA which are compatible with SFC.
For the AnN and AnA which are compatible with SFC, refer to the MELSAP-II Programming Manual.
Table App2.1 Special Relay List (Continue)
Number
Name
Description
Details
Applicable CPU
M9180
Active step
sampling trace
complete flag
OFF:Trace start
ON: Trace complete
• Turned on when sampling trace of all specified
blocks is completed. Turned off when sampling
trace is started.
—
Usable with AnN*,
AnA*, AnU,
A2AS, QCPU-A
(A Mode), A2C,
A0J2H, AnS,
AnSH, A1FX and
A52G.
M9181
Active step
sampling trace
execution flag
OFF:Trace not executed.
ON: Trace being
executed.
• Turned on when sampling trace is being executed.
Turned off when sampling trace is completed or
suspended.
—
Usable with AnN*,
AnA*, AnU,
A2AS, QCPU-A
(A Mode), A2C,
A0J2H, AnS,
AnSH, A1FX and
A52G.
*2
M9182
Active step
sampling trace
enable
OFF:Trace disable/
suspend
ON: Trace enable
• Selects sampling trace execution enable/disable.
ON: Sampling trace execution is enabled.
OFF: Sampling trace execution is disabled.
If turned off during sampling trace
execution, trace is suspended.
—
Usable with AnN*,
AnA*, AnU,
A2AS, QCPU-A
(A Mode), A2C,
A0J2H, AnS,
AnSH, A1FX and
A52G.
*2
M9196
Operation
output at block
stop
OFF:Coil output off
ON: Coil output on
• Selects the operation output when block stop is
executed.
ON: Retains the ON/OFF status of the coil being
used by using operation output of the step
being executed at block stop.
OFF: All coil outputs are turned off. (Operation
output by the SET instruction is retained
regardless of the ON/OFF status of M9196.)
—
Usable with AnN*,
AnA*, AnU,
A2AS, QCPU-A
(A Mode), A2C,
A0J2H, AnS,
AnSH, A1FX and
A52G.
M9197
Fuse blow, I/O
verify error
display
switching
M
9197
M
9198
I/O numbers
to be
displayed
• Switches I/O numbers in the fuse blow module
storage registers (D9100 to D9107) and I/O
module verify error storage registers (D9116 to
D9123) according to the combination of ON/OFF
of the M9197 and M9198.
—
Usable with AnU,
A2AS and QCPU-
A (A Mode)
OFF OFF X/Y0 to 7F0
ON OFF
X/Y800 to
FF0
M9198
OFF ON
X/Y1000 to
17F0
ON
ON
X/Y1800 to
1FF0
M9199
Data recovery
of online
sampling trace /
status latch
OFF:Data recovery OFF
ON: Data recovery ON
• When sampling trace / status latch is executed,
the setting data stored in the CPU module is
recovered to enable restart.
• Turn on M9199 to execute again.
(There is no need to write data with the peripheral
device.)
—
Usable with AnU,
A2AS and QCPU-
A (A Mode)
Содержание A2USCPU(S1)
Страница 1: ......
Страница 2: ......
Страница 18: ...A 16 Memo...
Страница 254: ...App 59 APPENDIX Appendix5 2 A1S61PN A1S62PN and A1S63P power supply modules Unit mm inch...
Страница 256: ...App 61 APPENDIX Appendix5 3 3 A1S35B main base unit Unit mm inch Appendix5 3 4 A1S38B main base unit Unit mm inch...
Страница 262: ...App 67 APPENDIX Appendix5 5 Memory cassette Appendix5 5 1 A2SNMCA 30KE memory cassette Unit mm inch...
Страница 271: ......
Страница 272: ......