background image

13

6. Trouble Shooting

Having trouble?

Here is the solution. (Unit is operating normally.)

Air conditioner does not heat or cool well.

 Clean the filter. (Airflow is reduced when the filter is dirty or clogged.)

 Check the temperature adjustment and adjust the set temperature.

 Make sure that there is plenty of space around the outdoor unit. Is the 

indoor unit air intake or outlet blocked?

 Has a door or window been left open?

When heating operation starts, warm air does not blow from the indoor 

unit soon.

 Warm air does not blow until the indoor unit has sufficiently warmed 

up.

During heating mode, the air conditioner stops before the set room tem-

perature is reached.

 When the outdoor temperature is low and the humidity is high, frost 

may form on the outdoor unit. If this occurs, the outdoor unit performs a 

defrosting operation. Normal operation should begin after approximately 

10 minutes.

During cooling mode, the air conditioner stops when the set room tem-

perature is reached.

  For SLZ-KF·VA series, when the set room temperature is reached during 

cooling mode, the fan operates at the lowest speed.

Airflow direction changes during operation or airflow direction cannot be 

set.

 During heating mode, the vanes automatically move to the horizontal 

airflow direction when the airflow temperature is low or during defrosting 

mode.

When the airflow direction is changed, the vanes always move up and down 

past the set position before finally stopping at the position.

 When the airflow direction is changed, the vanes move to the set position 

after detecting the base position.

A flowing water sound or occasional hissing sound is heard.

 These sounds can be heard when refrigerant is flowing in the air condi

-

tioner or when the refrigerant flow is changing.

A cracking or creaking sound is heard.

 These sounds can be heard when parts rub against each due to expan-

sion and contraction from temperature changes.

The room has an unpleasant odor.

  The indoor unit draws in air that contains gases produced from the walls, 

carpeting, and furniture as well as odors trapped in clothing, and then 

blows this air back into the room.

A white mist or vapor is emitted from the indoor unit.

 If the indoor temperature and the humidity are high, this condition may 

occur when operation starts.

 During defrosting mode, cool airflow may blow down and appear like a 

mist.

Water or vapor is emitted from the outdoor unit.

 During cooling mode, water may form and drip from the cool pipes and 

joints.

 During heating mode, water may form and drip from the heat exchang-

er.

 During defrosting mode, water on the heat exchanger evaporates and 

water vapor may be emitted.

” appears in the remote controller display.

  During central control, “

” appears in the remote controller display and 

air conditioner operation cannot be started or stopped using the remote 

controller.

When restarting the air conditioner soon after stopping it, it does not oper-

ate even though the ON/OFF button is pressed.

 Wait approximately three minutes.

  (Operation has stopped to protect the air conditioner.)

Air conditioner operates without the ON/OFF button being pressed.

 Is the on timer set?

  Press the ON/OFF button to stop operation.

 Is the air conditioner connected to a central remote controller?

  Consult the concerned people who control the air conditioner.

 Does “

” appear in the remote controller display?

  Consult the concerned people who control the air conditioner.

 Has the auto recovery feature from power failures been set?

  Press the ON/OFF button to stop operation.

Air conditioner stops without the ON/OFF button being pressed.

 Is the off timer set?

  Press the ON/OFF button to restart operation.

 Is the air conditioner connected to a central remote controller?

  Consult the concerned people who control the air conditioner.

 Does “

” appear in the remote controller display?

  Consult the concerned people who control the air conditioner.

Remote controller timer operation cannot be set.

 Are timer settings invalid?

  If the timer can be set, 

 or 

 appears in the remote controller display.

“PLEASE WAIT” appears in the remote controller display.

 The initial settings are being performed. Wait approximately 3 min-

utes.

An error code appears in the remote controller display.

 The protection devices have operated to protect the air conditioner.

 Do not attempt to repair this equipment by yourself.

  Turn off the power switch immediately and consult your dealer. Be sure 

to provide the dealer with the model name and information that appeared 

in the remote controller display.

Draining water or motor rotation sound is heard.

  When cooling operation stops, the drain pump operates and then stops. 

Wait approximately 3 minutes.

The vanes do not move or the indoor unit does not respond to input from 

the wireless remote controller.

  The junction wire connectors of the vane motor and signal receiver may 

not be connected correctly. Have an installer check the connections. (The 

colors of the male and female sections of the junction wire connectors 

must match.)

RG79Y733H01_en.indd   13

7/3/2015   5:54:47 PM

Содержание SLZ-KF25VA

Страница 1: ...ra segurança e utilização correctas leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar condicionado DRIFTSMANUAL Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används Français Deutsch English Nederlands Español Italiano Português Svenska ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ ΧΡΗΣΕΩΣ Για ασφάλεια και σωστή χρήση παρακαλείστε διαβάσετε προσεχτικά αυτό το...

Страница 2: ... spray combustible gas close to the unit Fire may result Do not place a gas heater or any other open flame appliance where it will be exposed to the air discharged from the unit Incomplete combustion may result Do not remove the front panel or the fan guard from the outdoor unit when it is running When you notice exceptionally abnormal noise or vibration stop operation turn off the power switch an...

Страница 3: ...the setting 3 RETURN button Press to return to the previous screen 4 MENU button Press to bring up the Main menu 5 Backlit LCD Operation settings will appear When the backlight is off pressing any button turns the backlight on and it will stay lit for a certain period of time depending on the screen When the backlight is off pressing any button turns the backlight on and does not perform its funct...

Страница 4: ...e All icons are displayed for explanation Fri Mode Temp Fan Room Cool Set temp Basic mode Fri Cool Mode Temp Fan Set temp 4 3 2 1 5 6 7 8 9 0 1 3 4 7 2 3 4 5 6 8 9 2 1 5 3 Appears when the On Off timer Night setback or Auto off timer func tion is enabled appears when the timer is disabled by the centralized control system 4 Appears when the Weekly timer is enabled 5 Appears while the units are ope...

Страница 5: ...te Only for wireless remote controller When using the wireless remote controller point it towards the receiver on the indoor unit If the remote controller is operated within approximately 2 minutes after power is supplied to the indoor unit the indoor unit may beep twice as the unit is performing the initial automatic check The indoor unit beeps to confirm that the signal transmitted from the remo...

Страница 6: ...f the indoor unit that operates earlier is selected The other indoor units that will start the operation later cannot operate indicating an operation state in blinking In this case please set all the indoor units to the same operation mode There might be a case that the indoor unit which is operating in Auto mode Cannot change over to the operating mode Cool Heat and becomes a state of standby Whe...

Страница 7: ...ting 3 5 1 Navigating through the Main menu Accessing the Main menu F1 F2 F3 F4 Main Main display Cursor Page Main menu Vane Louver Vent Lossnay High power Timer Weekly timer OU silent mode Item selection F1 F2 F3 F4 Main Main display Cursor Page Main menu Vane Louver Vent Lossnay High power Timer Weekly timer OU silent mode Cursor Navigating through the pages F1 F2 F3 F4 Main Main display Cursor ...

Страница 8: ... identification marks Outlet No 3 Outlet No 2 Remote controller setting The airflow direction of this outlet is controlled by the airflow direc tion setting of remote controller Fixed The airflow direction of this outlet is fixed in particular direction When it is cold because of direct airflow the airflow direction can be fixed horizontally to avoid direct airflow How to set the fixed up down air...

Страница 9: ...will be made to the selected outlet The screen will automatically return to the one shown above step 5 when the transmission is completed Make the settings for other outlets following the same procedures If all outlets are selected will be displayed the next time the unit goes into operation Navigating through the screens To go back to the Main menu MENU button To return to the previous screen RET...

Страница 10: ...o be fixed with the F2 or F3 button and press the SELECT button Ref address Refrigerant address Unit No 1 2 3 4 Press the F4 button to confirm the unit The vane of only the target indoor unit is pointing downward 2 Select the menu with the F4 but ton Default Area Direct Indirect Default Default The vanes move the same as during normal operation During cooling mode all of the vanes move to the hori...

Страница 11: ...only Cooling Heating OFF After changing the setting press the SELECT button to save the setting OFF The function is disabled Cooling only The function is ena bled only during cooling mode Heating only The function is ena bled only during heating mode Cooling Heating The function is enabled during both cooling mode and heating mode 3 When No occupancy Auto OFF is selected Set the time with the F3 o...

Страница 12: ...in direct sunlight or by using a heat source such as an electric heater this may warp them Do not wash the filters in hot water above 50 C as this may warp them Make sure that the air filters are always installed Operating the unit without air filters can cause malfunction Caution Before you start cleaning stop operation and turn OFF the power supply Indoor units are equipped with filters to remov...

Страница 13: ...oor unit During cooling mode water may form and drip from the cool pipes and joints During heating mode water may form and drip from the heat exchang er During defrosting mode water on the heat exchanger evaporates and water vapor may be emitted appears in the remote controller display During central control appears in the remote controller display and air conditioner operation cannot be started o...

Страница 14: ...on Apply grounding Do not connect a grounding wire to a gas pipe water pipe lightning rod or ground wire of a telephone If a grounding is incorrect it may cause an electric shock Install an earth leakage breaker depending on the place where the air conditioner is to be installed humid place etc If the earth leakage breaker is not installed it may cause an electric shock Inspection and maintenance ...

Страница 15: ...ection Notes 1 This figure indicates GRILLE s 2 Specifications subject to change without notice Guaranteed operating range Indoor Outdoor Cooling Upper limit 32 C DB 23 C WB 46 C DB Lower limit 21 C DB 15 C WB 10 C DB 15 C DB 1 Heating Upper limit 27 C DB 24 C DB 18 C WB Lower limit 20 C DB 10 C DB 11 C WB 1 Depend on outdoor unit Units should be installed by licensed electric contractor according...

Страница 16: ...обученным персоналом в магазинах на предприятиях легкой промышленности и фермах или для коммерческого применения непрофессионалами Данным устройством могут пользоваться дети старше 8 лет и лица с ограниченными физическими сенсорными или умственными возможностями или недостаточным опытом или знаниями под наблюдением ответственного лица или после обучения пользованию устройством с разъяснением прави...

Страница 17: ...тво нахо дится в работе Индикатор будет мигать при включении контролле ра или при возникновении ошибки 7 Функциональная кнопка F1 Главное окно нажмите для изменения режима работы Главное меню нажмите чтобы переместить курсор вниз 8 Функциональная кнопка F2 Главное окно нажмите для уменьшения температуры Главное меню нажмите чтобы переместить курсор верх 9 Функциональная кнопка F3 Главное окно нажм...

Страница 18: ... Отображается когда кнопки заблокированы Полный режим отображения Все значки показаны для иллюстрации и описания Базовый режим отображения 3 Отображается когда включена функция Таймер ВКЛ ВЫКЛ Ночной режим или Автоотключение таймера появляется когда таймер отключен централизованной систе мой управления 4 Отображается когда включен таймер на неделю 5 Отображается пока изделие работает в режиме энер...

Страница 19: ...го управления и не подвергайте его сильным ударам Кроме того следите за тем чтобы пульт дис танционного управления не попал в воду и не оставляйте его в местах с высокой влажностью Во избежание неправильного местоположения пульта дистанционного управления установите на стене держатель входящий в комплект поставки пульта дистанционного управления и обязательно устанавливайте пульт дистанционного уп...

Страница 20: ...аружному прибору В соответ ствии с мощностью два или более приборов могут работать одновременно При попытке включить один или несколько внутренних приборов с одним наружным прибором одновременно один для охлаждения а другой для обогрева выбирается режим того внутреннего при бора который включится раньше Другие внутренние приборы которые включатся позже работать не будут указывая на режим работы ми...

Страница 21: ...тва в режиме сушки DRY 3 5 Настройка направления воздушного потока 3 5 1 Навигация по главному меню Доступ к главному меню F1 F2 F3 F4 Main Main display Cursor Page Main menu Vane Louver Vent Lossnay High power Timer Weekly timer OU silent mode Выбор элементов F1 F2 F3 F4 Main Main display Cursor Page Main menu Vane Louver Vent Lossnay High power Timer Weekly timer OU silent mode Стрелка Навигация...

Страница 22: ...огда подключен блок Lossnay Off Low High Off Low High Вентилятор на некоторых моделях внутренних блоков может блокиро ваться при использовании с некото рыми моделями блоков вентиляции Нажмите кнопку ВОЗВРАТ что бы вернуться в Главное меню Reset 1 horizontal 2 3 4 5 Горизонтальный воздушный поток Вниз Установка пульта дистан ционного управления Направление воздушного потока из этого отверстия управ...

Страница 23: ...Экран автоматически возвратиться к одному из показанных ранее видов Уровень 5 после завершения передачи Выполните настройку для других выпусков используя аналогичную процедуру Если выбраны все выпуски будет отображаться ког да блок вступит в работу в следующий раз Навигация по экранам Для возврата в Главное меню кнопка МЕНЮ Для возврата к предыдущему экрану кнопка ВОЗВРАТ Процедура подтверждения F...

Страница 24: ...вну треннего прибора направляется вниз 2 Откройте меню нажатием кнопки F4 Default По умолчанию Area Площадь Direct Indirect Пря мой непрямой Default По умолчанию Default По умолчанию лопатки будут перемещаться так же как и в стандартном режиме работы В режиме охлаждения все лопат ки будут расположены так чтобы обеспечить горизонтальный по ток воздуха В режиме обогрева все лопатки наклоняются так ч...

Страница 25: ...кл После изменения настройки на жмите кнопку ВЫБОР для ее сохранения OFF Выкл функция отключе на Cooling only Только охлажде ние данная функция доступна только в режиме охлаждения Heating only Только обогрев данная функция доступна только в режиме обогрева Cooling Heating Охлаждение обогрев данная функция до ступна в режиме охлаждения или обогрева 3 П р и в ы б о р е р еж и м а N o occupancy Auto ...

Страница 26: ...в беспроводных пультах дистанцион ного управления A B D C Осторожно Обратитесь к специалистам для очистки фильтра Чистка фильтров Проводите чистку фильтров с использованием пылесоса При отсут ствии пылесоса легким постукиванием фильтра о твердый предмет стряхните с него грязь или пыль Если фильтры сильно загрязнены промойте их в теплой воде Тща тельно смойте остатки моющего средства и полностью пр...

Страница 27: ...капать с хо лодных труб и стыков В режиме обогрева вода может образовываться и капать с теплообменника В режиме размораживания вода на теплообменнике испаряется и может появиться водяной пар На дисплее пульта дистанционного управления отображается При центральном управлении на пульте дистанционного управле ния появляется и запустить или остановить работу кондици онера с пульта дистанционного управ...

Страница 28: ...ьствовать об утечке хладагента По сле выполнения ремонта обязательно спросите у представителя сервисной службы о наличии или отсутствии утечки хладагента Хладагент заправленный в систему кондиционера не пред ставляет опасности для здоровья Обычно утечки хладагента не наблюдается однако в случае утечки газообразного хладагента Электромонтажные работы Обеспечьте отдельный контур сети для питания кон...

Страница 29: ...росов обращайтесь к своему дилеру 8 Технические характеристики Модель SLZ KF25VA SLZ KF35VA SLZ KF50VA SLZ KF60VA Электропитание Напряжение В Частота Гц N 230V 50Hz Номинальная потребляемая мощность Только внутренний прибор кВт 0 02 0 02 0 03 0 04 Номинальный ток Только внутренний прибор A 0 20 0 24 0 32 0 43 Габариты Высота мм 245 10 Габариты Ширина мм 570 625 Габариты Глубина мм 570 625 Скорость...

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ... представитель в ЕС уполномоченный на составление технического фай ла указан ниже MITSUBISHI ELECTRIC EUROPE B V HARMAN HOUSE 1 GEORGE STREET UXBRIDGE MIDDLESEX UB8 1QQ U K Masahiko KONISHI Product Marketing Director Issued 6 June 2015 Tomoyuki MIWA THAILAND Manager Quality Assurance Department Revised date THAILAND hereby declares under its sole responsibility that the air conditioners and heat p...

Страница 34: ...ere taalversies zijn vertalingen van het origineel VOORZICHTIG Het lekken van koelvloeistof kan verstikking veroorzaken Zorg voor ventilatie in overeen stemming met EN378 1 Isoleer de leidingen met isolatiemateriaal Direct contact met de onbedekte leidingen kan leiden tot brandwonden of bevriezing Stop nooit batterijen in uw mond om inslikking te voorkomen Het inslikken van batterijen kan verstikk...

Страница 35: ... in EU MITSUBISHI EUROPE B V HARMAN HOUSE 1 GEORGE STREET UXBRIDE MIDDLESEX UB8 1QQ U K RG79Y733H01 Не забудьте указать контактный адрес номер телефона в данном руководстве прежде чем передать его клиенту Please be sure to put the contact address telephone number on this manual before handing it to the customer Please be sure to put the contact address telephone number on this manual before handin...

Отзывы: