5 MANUAL CONTROL
5.1 Outline of Manual Control
163
5
5
MANUAL CONTROL
The details and usage of manual control are explained in this chapter.
In manual control, commands are issued during a JOG operation and an inching operation executed by the turning ON of the
JOG start signal, or from a manual pulse generator connected to the Simple Motion module.
Manual control using a program from the CPU module is explained in this chapter.
5.1
Outline of Manual Control
Three manual control methods
"Manual control" refers to control in which positioning data is not used, and a positioning operation is carried out in response
to signal input from an external device.
The three types of this "manual control" are explained below.
JOG operation
"JOG operation" is a control method in which the machine is moved by only a movement amount (commands are
continuously output while the JOG START signal is ON). This operation is used to move the workpiece in the direction in
which the limit signal is ON, when the operation is stopped by turning the limit signal OFF to confirm the positioning system
connection and obtain the positioning data address (
Inching operation
"Inching operation" is a control method in which a minute movement amount of command is output manually in operation
cycle. When the "inching movement amount" of the axis control data is set by JOG operation, the workpiece is moved by a set
movement amount. (When the "inching movement amount" is set to "0", the machine operates as JOG operation.)
M
JOG START signal
ON
OFF
Movement continues while
the JOG START signal is ON.
M
JOG start signal is turned
ON to move the workpiece
by the movement amount
of pulses which is output in
operation cycle.
JOG start signal
ON
OFF
Содержание RD77MS16
Страница 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Страница 2: ......
Страница 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Страница 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Страница 574: ...572 13 PROGRAMMING 13 4 Positioning Program Examples Parameter initialization program Flash ROM write program ...
Страница 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Страница 643: ......