![Mitsubishi Electric RD77MS16 Скачать руководство пользователя страница 144](http://html.mh-extra.com/html/mitsubishi-electric/rd77ms16/rd77ms16_user-manual_1811857144.webp)
142
3 MAJOR POSITIONING CONTROL
3.2 Setting the Positioning Data
LEND
The LEND is used to return the operation to the top of the repeat (LOOP to LEND) loop.
Operation
When the repeat cycle designated by the LOOP becomes 0, the loop is terminated, and the next positioning data No.
processing is started. (The operation pattern, if set to "Positioning complete", will be ignored.)
When the operation is stopped after the repeat operation is executed by designated cycles, the dummy positioning data (for
example, incremental positioning without movement amount) is set next to LEND.
The following table shows the operation when the positioning complete (00) is set to LOOP and LEND.
Setting positioning data
When using the LEND, set the following positioning data.
: Always set,
: Set as required,
: Setting not required
*1
Refer to the following for information on the setting details.
Restrictions
• Ignore the "LEND" before the "LOOP" is executed.
• When the operation pattern "Positioning complete" has been set between LOOP and LEND, the positioning control is
completed after the positioning data is executed, and the LOOP control is not executed.
Positioning data No.
Operation pattern
Control method
Conditions
Operation
1
Continuous control
ABS2
Executed in the order of the positioning data No. 1
2
3
4
5
2
3
4
5
6.
(The operation patterns of the positioning data Nos. 2 and 5
are ignored.)
2
Positioning complete
LOOP
Number of loop
cycles: 2
3
Continuous path
control
ABS2
4
Continuous control
ABS2
5
Positioning complete
LEND
6
Positioning complete
ABS2
Setting item
Setting required/not required
[Da.1]
Operation pattern
[Da.2]
Control method
(Set the LEND.)
[Da.3]
Acceleration time No.
[Da.4]
Deceleration time No.
[Da.6]
Positioning address/movement amount
[Da.7]
Arc address
[Da.8]
Command speed
[Da.9]
Dwell time/JUMP destination positioning data No.
[Da.10]
M code/Condition data No./Number of LOOP to LEND repetitions/
Number of pitches
[Da.20]
Axis to be interpolated No.1
[Da.21]
Axis to be interpolated No.2
[Da.22]
Axis to be interpolated No.3
[Da.27]
M code ON signal output timing
[Da.28]
ABS direction in degrees
[Da.29]
Interpolation speed designation method
Содержание RD77MS16
Страница 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Страница 2: ......
Страница 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Страница 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Страница 574: ...572 13 PROGRAMMING 13 4 Positioning Program Examples Parameter initialization program Flash ROM write program ...
Страница 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Страница 643: ......