Model:

 PUMY-P60NKMU (-BS)

Model Name

Unit Type

PUMY-P60NKMU (-BS)

Nominal Cooling Capacity

Btu/h

60,000

Nominal Heating Capacity

Btu/h

66,000

Operating Temperature Range 

Cooling (Outdoor) *1

23° F ~ 115° F (-5 ° ~ +46° C) DB*

Heating (Outdoor)

-4° F ~ +60° F (-20 ° ~ +15° C) WB

External Dimensions (H x W x D)

In. / mm

52-11/16 x 41-5/16 x 13 (+1-3/16) / 1,338 x 1050 x 330 (+30)

Net Weight

Lbs. / kg

313 / 142

Electrical Power Requirements

Voltage, Phase, Hertz

208 / 230V, 1-phase, 60Hz

Cooling Power Input 

kW

4.80

Heating Power Input 

kW

6.15

Cooling Current 

A

21.5

Heating Current 

A

27.6

Minimum Circuit Ampacity (MCA)

A

35

Recommended Fuse/Breaker Size

A

40

Maximum Fuse Size

A

42

Piping Diameter (Brazed) (In. / mm)

Liquid (High Pressure)

3/8 / 9.52

Gas (Low Pressure)

3/4 / 19.05

Indoor Unit

Total Capacity

50 to 130% of Outdoor Unit Capacity

Model / Quantity

P06 to P72 / 1 to 12

Sound Pressure Levels

dB(A)

58/59

Fan

Type x Quantity

Propeller Fan x 2

CFM

4,940

Compressor Operating Range

22% to 100%

Compressor Type x Quantity

INVERTER-driven Scroll Hermetic x 1

Compressor Motor Output

kW

3.0

Refrigerant

R410A

Lubricant

FV50S

High-pressure Protection Device

High Pressure Switch

Compressor / Fan Protection Device

Compressor Thermo / Overcurrent Detection

Inverter Protection Device

Overheat / Voltage Protection

AHRI Ratings

(Ducted / Non-Ducted)

EER

11.3 / 12.5

SEER

16.5 / 16.7

COP

3.70 / 3.14

Blue Fin Anti-corrosion Protection: 

Cellulose- and polyurethane-resin coating treatment applied to condenser coil that protects it from air contaminants;  

≥1μm

 thick; Salt Spray Test Method - no unusual rust development to 960 hours.

SEACOAST PROTECTION

 

 External Panel Base, External Front Panel, Pillar: Alloyed galvanized-steel sheets with thermoset polyester-resin coating on internal and external surfaces

 Compressor Cover: Galvanized-aluminum sheets with thermoset polyester-resin coating on internal and external surfaces

 Electrical Parts Box: Galvanized-aluminum sheets with thermoset polyester-resin coating on external surface

 Fan Motor Support: Galvanized-steel sheets with thermoset polyester-resin coating on internal and external surfaces

 Printed Circuit Board: Epoxy resin with polyurethane-coating on external surface

OUTDOOR VRF SYSTEM FEATURES

 

  

zoning technology

  Inverter-driven (variable speed) compressor

  Total refrigerant piping length of 492' (150 m)

  Uses CITY MULTI indoor units and Controls Network

UNIT OPTION

 

Standard Model……………………….....PUMY-P60NKMU

 

Sea Coast (BS) Model…………......PUMY-P60NKMU-BS

OPTIONAL PARTS

 

Branch Joint (T-Branch)………………………………...CMY-Y62-G-E

 

Header - Four-Branch…………………………………......CMY-Y64-G-E

 

Header - Eight-Branch…………………………………..CMY-Y68-G-E

 

 

 

 

 

Base Heater………………………………………........ PAC-SJ19BH-E

NOTES: 
*1 If PKFY-P06/08 indoor units are connected, then range is 50° F ~ 115° F (10° C ~ 46° C). 
 

PUMY-P60NKMU (-BS)