20
OCH733
<Heating>
PUMY-HP36NKMU1
PUMY-HP48NKMU1
Figure 11 Indoor unit temperature correction
To be used to correct indoor unit capacity only
Figure 12 Outdoor unit temperature correction
To be used to correct outdoor unit capacity only
15
16
17
18
19
20
21
22
23
24
25
26
27
59 60.8 62.6 64.4 66.2 68 69.8 71.6 73.4 75.2 77 78.8 80.6
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
Ratio of heating capacity
Indoor Temperature
[°C D.B.]
[°F D.B.]
-25
-20
-15
-10
-5
0
5
10
15
-13
-4
5
14
23
32
41
50
59
0.8
0.7
0.6
0.5
0.4
1.4
1.3
1.2
1.1
1.0
0.9
Outdoor Temperature
[°C W.B.]
[°F W.B.]
70.0°F (21.1°C) D.B.
Ratio of heating capacity
Indoor Temperature
Indoor Temperature
-25
-20
-15
-10
-5
0
5
10
15
-13
-4
5
14
23
32
41
50
59
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
Ratio of power input
Outdoor Temperature
[°C W.B.]
[°F W.B.]
70.0°F (21.1°C) D.B.
61.0°F (16.0°C) D.B.
79.0°F (26.0°C) D.B.