15
6
OUTLINES AND DIMENSIONS
PUH-P1.6VGA, PU-P1.6VGA
PUH-P1.6YGA
3
2
1
T
S
R
w
1 234
w
1 209
500
Power Supply Wiring Hole
(2-
[
27Knock-Out)
Right Piping Hole
(Knock-Out)
Power Supply Wiring Hole
(2-
[
27Knock-Out)
T
erminal Connections
Left...Power supply Wiring
Right..Indoor/Outdoor Wiring
70
70
155
155
155
109
30
215
85
Bottom Piping Hole
(Knock-Out)
Drain Hole
(5-
[
33holes)
18
18
424
900
318
Handle for moving
Earth Point
Service Panel
Front Piping Cover
Rear Piping Cover
1
2
Side
Air
Intake
200
200
53
370
(14)
412
29
330
55
43
51
Rear
Air Intake
Air Discharge
2-U Shaped notched holes
(Foundation Bolt M10)
2-12x40 oval holes
(Foundation Bolt M10)
20
28
58
Installation Feet
Rear
Air
Intake
Side
Air
Intake
Handle for
moving
3
230
220
220
230
637
30
30
Rear
T
runking Hole
(Knock-Out)
< Rear Side >
Power Supply Wiring Hole
(2-
[
27Knock-Out)
40
33
22
55
68
63
65
92
Rear Piping Hole
(Knock-Out)
[
92
Piping Knock-Out Hole Details
. . .
Refrigerant GAS pipe connection (FLARE)
[
15.88 (5/8F)
. . .
Refrigerant LIQUID pipe connection (FLARE)
[
9.52 (3/8F)
. . .
Height of ST
OP
V
AL
VE connection location.
1
2
Front
T
runking Hole
(Knock-Out)
< Right Side >
< Front Side >
Explanation of Notes
40
68
63
22
55
65
92
33
27100
50
50
100
33
[
92
Front Piping Hole
(Knock-Out)
5540
3
. . .
3-
[
3.6 holes (for securing the top of the unit)
These holes are provided for cases where the unit must
be secured by the base
AND by the top surface.
Use Self
T
apping screws 5 x L15 or less.(Obtained locally)
w
1
Over 10mm
F
R
E
E
Over 500mm
Less than
30mm
FREE SP
ACE (Around the Unit)
Piping and wiring connections
can be made from 4 directions:
Front, Right, Rear and Below
.
FOUNDA
TION BOL
TS
1
The diagram below shows a
basic example.
Explanation of particular details are
given in the installation manuals etc.
SER
VICE SP
ACE
Dimensions of space needed
for service access are
shown in the below diagram.
2
Over500
Over500
PIPING-WIRING DIRECTIONS
4
3
FOUNDA
TION
<Foundation bolt height>
Please secure the unit firmly
with 4 foundation (M10) bolts.
(Bolts and washers must be
purchased locally).
Service Space
Over 100mm
Over 10mm
Over10
Over100
Unit : mm
OC180A--1.qxp 3/3/00 8:43 AM Page 15
Содержание PU-P1.6VGA
Страница 2: ...OC180A 1 qxp 3 3 00 8 43 AM Page 2 ...
Страница 19: ...19 7 WIRING DIAGRAM PUH P1 6 2 2 5 3VGA PUH P2 5VGA1 OC180A 1 qxp 3 3 00 8 44 AM Page 19 ...
Страница 20: ...20 PUH P1 6 2 2 5 3 4 5 6YGA PUH P2 5YGA1 OC180A 1 qxp 3 3 00 8 44 AM Page 20 ...
Страница 21: ...21 PU P1 6 2 2 5 3VGA PU P2 5VGA1 OC180A 1 qxp 3 3 00 8 45 AM Page 21 ...
Страница 22: ...22 PU P3 4 5 6YGA OC180A 1 qxp 3 3 00 8 45 AM Page 22 ...