19
Note8. When room temperature is 18°C or below, the compressor can not turn ON. When the room temperature rises to
18°C or above, the compressor will start operation after a 3-minute time delay.
Note9. Refer to page 23 for the compressor operation time.
Note10. In DRY operation, the indoor fan runs on the low speed during the compressor ON and stops during the compressor
OFF.
3. DRY operation
Dry operation
Room
temperature
18
°
C or below
Compressor ON
Compressor ON
3 min. elapse
Compressor
thermostat ON
Compressor ON
time completed
Compressor OFF
10-minute timer start
Compressor OFF
Fan stop
Compressor ON
3 min. delay
YES
YES
YES
YES
YES
YES
YES
YES
<Note 10>
<Note 10>
<Note 5>
<Note 5>
<Note 9>
<Note 8>
YES
NO
NO
NO
NO
NO
NO
NO
Compressor
thermostat ON
Compressor OFF
10 minutes completed
Compressor ON
time set
Compressor ON
Fan speed LOW
1
OC232--1.qxp 01.10.1 9:17 PM Page 19