(d) Enabling the setting
Enable the setting contents by either of the following.
• Turning off and on Initial data setting request flag (RY9) while the operations of all channels are stopped
• Turning off and on During operation setting change instruction (RY10)
(e) Default value
The default values are set to 0 in all channels.
(46)CH
Process alarm alert output enable/disable setting (address: 250H, 259H,
262H, 26BH)
Set whether to enable or disable alert output of process alarm. For details on the process alarm, refer to the
following.
(a) Setting range
• 0: Enable
• 1: Disable
(b) Enabling the setting
To enable the setting, turn off and on Initial data setting request flag (RY9) while the operations of all channels
are stopped.
(c) Default value
The default values are set to Disable (1) in all channels.
Temperature
Input