![Mitsubishi Electric NZ2GF-ETB Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/mitsubishi-electric/nz2gf-etb/nz2gf-etb_user-manual_238762027.webp)
25
CHAPTER 2 PART NAMES
2
2.
2 CC-Link I
E
F
ield
N
e
tw
ork
P
a
rt
Remark
●
LED indication during line test execution
While a line test is being performed from the master station, the following LEDs are flashing.
• MODE LED
• D LINK LED
•
100 LED
For execution of the line test, refer to the following.
User's manual for the master/local module used
ERR. LED
Indicates the error status of the Ethernet adapter module. The error details can be checked by the CC-Link IE Field
Network diagnostics. (
On: One of the following errors occurred in the Ethernet adapter module.
• Multiple modules with the same station number exist on CC-Link IE Field Network.
• Network parameters for CC-Link IE Field Network is corrupted. Or, there is an error in the reserved station setting, the
number of connected stations, or the network number setting.
• There is an error in the network parameter settings for the Ethernet adapter module.
Off: Normally operating.
L ERR. LED
Indicates the error status of the received data and the line. When this LED is on, check the L ER LED for "P1" or "P2" to
see on which port the error was detected.
The error details can be checked by the CC-Link IE Field Network diagnostics. (
This LED automatically turns off when the module has received normal data and loopback is completed.
On:
• The Ethernet adapter module has received abnormal data.
• The Ethernet adapter module is performing loopback (only the Ethernet adapter module with a serial number (first five
digits) of "12102" or later).
Off:
• The Ethernet adapter module has received normal data.
• The Ethernet adapter module does not perform loopback (only the Ethernet adapter module with a serial number (first
five digits) of "12102" or later).
STATION
NO.
Indicates the station number of the Ethernet adapter module.
On: Indicates the station number.
Station No.15
Off: The station number has not been set.
Name
Description
Ex.
1
10
100
10
5
+
= 15
1
2
8
4
: On
: Flashing
Flashing
Содержание NZ2GF-ETB
Страница 1: ...CC Link IE Field Network Ethernet Adapter Module User s Manual NZ2GF ETB ...
Страница 2: ......
Страница 49: ...47 CHAPTER 4 PROCEDURE BEFORE THE OPERATION 4 4 1 Start Up Procedure Memo ...
Страница 82: ...80 10 The following dialog box is displayed 11 Set the switch on the Ethernet adapter module to RUN Click ...
Страница 198: ...196 a Detail Setting ...
Страница 246: ...244 Memo ...
Страница 253: ......