8-1. TIMER SHORT MODE
For service, the following set time can be shortened by bridging JPG and JPS on the electronic control P.C. board.
(Refer to 10-7.)
• The set time for the ON/OFF timer can be reduced to 1 second for each minute.
• After the breaker is turned on, the time for starting the compressor, which normally takes 3 minutes, can be reduced
to 1 minute. Restarting the compressor, which takes 3 minutes, cannot be reduced.
8-2. P.C. BOARD MODIFICATION FOR INDIVIDUAL OPERATION (MSZ-SF•VE)
A maximum of 4 indoor units with wireless remote controllers can be used in a room.
In this case, to operate each indoor unit individually by each remote controller, P.C. boards of remote controller must be
modified according to the number of the indoor unit.
How to modify the remote controller P.C. board
Remove batteries before modification.
The board has a print as shown below:
NOTE:
For modification, take out the batteries and press the OPERATE/STOP (ON/OFF) (
MSZ-SF·VE
) button 2 or 3 times at
first.
After modification, put back the batteries then press the RESET button.
SERVICE FUNCTIONS
8
MSZ-SF25VE MSZ-SF35VE MSZ-SF42VE MSZ-SF50VE
MSZ-SF25VE2 MSZ-SF35VE2 MSZ-SF42VE2 MSZ-SF50VE2
MSZ-SF25VE3 MSZ-SF35VE3 MSZ-SF42VE3 MSZ-SF50VE3
The P.C. board has the print “J1” and “J2”. Solder “J1” and “J2” according to the number of indoor unit as shown in Table 1.
After modification, press the RESET button.
J1
J2
Table 1
1 unit operation
2 units operation
3 units operation
4 units operation
No. 1 unit
No modifi cation
Same as at left
Same as at left
Same as at left
No. 2 unit
—
Solder J1
Same as at left
Same as at left
No. 3 unit
—
—
Solder J2
Same as at left
No. 4 unit
—
—
—
Solder both J1 and J2
How to set the remote controller exclusively for particular indoor unit
After you turn the breaker ON, the first remote controller that sends the signal to the indoor unit will be regarded as the remote
controller for the indoor unit.
The indoor unit will only accept the signal from the remote controller that has been assigned to the indoor unit once they are set.
The setting will be cancelled if the breaker is turned OFF, or the power supply is shut down.
Please conduct the above setting once again after the power has restored.
OBH600E
Содержание MSZ-SF25VE
Страница 12: ...12 MSZ SF25VE E1 E2 EN1 EN2 MSZ SF42VE E1 E2 EN1 EN2 WIRING DIAGRAM 6 MSZ SF25VE ER2 MSZ SF42VE ER2 OBH600E ...
Страница 13: ...13 MSZ SF35VE E1 E2 EN1 EN2 MSZ SF50VE E1 E2 EN1 EN2 MSZ SF35VE ER2 MSZ SF50VE ER2 OBH600E ...
Страница 14: ...14 MSZ SF25VE2 E1 EN1 ER1 MSZ SF42VE2 E1 EN1 ER1 MSZ SF35VE2 E1 EN1 ER1 MSZ SF50VE2 E1 EN1 ER1 OBH600E ...
Страница 15: ...15 MSZ SF25VE3 E1 EN1 ER1 MSZ SF42VE3 E1 EN1 ER1 MSZ SF35VE3 E1 EN1 ER1 MSZ SF50VE3 E1 EN1 ER1 OBH600E ...