7
Specifications and rated conditions of main electric parts
Fuse
(F11)
T3.15AL250V
Horizontal vane motor
(MV)
12 VDC
Varistor
(NR11)
S10K300E2K1 (ERZV10D471)
Terminal block
(TB)
3P
Indoor model
MSZ-EF42VEW
MSZ-EF42VEB
MSZ-EF42VES
MSZ-EF42VE2W
MSZ-EF42VE2B
MSZ-EF42VE2S
MSZ-EF50VEW
MSZ-EF50VEB
MSZ-EF50VES
MSZ-EF50VE2W
MSZ-EF50VE2B
MSZ-EF50VE2S
Power supply
Single phase 230 V, 50 Hz
Electrical
data
Power input
1
Cooling
W
14
18
Heating
31
34
Running
current 1
Cooling
A
0.14
0.18
Heating
0.30
0.32
Fan
motor
Model
RC0J40
Current 1
Cooling
A
0.14
0.18
Heating
0.30
0.32
Dimensions W × H × D
mm
895 × 299 × 195
(
EF•VEW/B/S
) / 885 × 299 × 195
(
EF•VE2W/B/S
)
Weight
kg
11.5
Special remarks
Air direction
5
Air
fl
ow
Cooling
Super High
m
3
/h
618
660
High
534
558
Med.
462
474
Low
396
408
Silent
348
Heating
Super High
m
3
/h
762
792
High
594
666
Med.
468
540
Low
378
438
Silent
330
384
Sound level
Cooling
Super High
dB(A)
42
43
High
39
40
Med.
35
36
Low
31
33
Silent
28
30
Heating
Super High
dB(A)
48
49
High
41
43
Med.
35
37
Low
30
33
Silent
28
30
Fan speed
Cooling
Super High
rpm
1,180
1,240
High
1,050
1,080
Med.
930
950
Low
830
850
Silent
750
Heating
Super High
rpm
1,400
1,440
High
1,140
1,250
Med.
940
1,060
Low
800
890
Silent
720
810
Fan speed regulator
5
Remote controller model
SG11D
(EF•VEW/B/S)
/ SG14D
(EF•VE2W/B/S)
NOTE
: Test conditions are based on ISO 5151.
Cooling: Indoor
Dry-bulb temperature 27°C Wet-bulb temperature 19°C
Outdoor Dry-bulb temperature 35°C
Heating: Indoor
Dry-bulb temperature 20°C
Outdoor Dry-bulb temperature 7°C Wet-bulb temperature 6°C
1 Measured under rated operating frequency.
OBH589D