2
TECHNICAL CHANGES
MSC-C07SV -
➔
MSC-C07TV -
MSC-C09SV -
➔
MSC-C09TV -
MSC-C12SV -
➔
MSC-C12TV -
1. Rated voltage has changed to 230V.
2. Remote controller has changed.
• Slide switch for setting the type has added on the remote controller.
Indoor units for MU type and MUH type are common specifications.
Set slide switch on the remote controller according to the type of outdoor unit.
E1
E1
E1
E1
E1
E1
1
MU-C07TV -
MU-C09TV -
MU-C12TV -
New model
MUH-C07SV -
➔
MUH-C07TV -
1. Rated voltage has changed to 230V.
2. Path of heat exchanger has changed.
3. Refrigerant filling capacity has changed.(0.85kg
➔
0.90kg)
4. Capillary tube has changed.(
{
3.0X
{
1.6X600
➔
{
3.0X
{
1.6X750,
{
3.0X
{
1.4X600
➔
{
3.0X
{
1.4X700)
5. Temperature of defrosting control has changed.
6. Additional refrigerant charge has been changed.(50g/m
➔
25g/m)
MUH-C09SV -
➔
MUH-C09TV -
1. Rated voltage has changed to 230V.
2. Outdoor heat exchanger has changed.
3. Refrigerant filling capacity has changed.(0.80kg
➔
1.00kg)
4. Capillary tube has changed.
(
{
3.0X
{
1.6X400
➔
{
3.0X
{
1.8X400,
{
3.0X
{
1.4X550
➔
{
3.0X
{
1.4X650,
{
3.0X
{
1.4X800 X2
➔
{
3.0X
{
1.4X500 X2)
5. Outdoor fan motor has changed.(RA6V23-EA
➔
RA6V33-CA)
6. Temperature of defrosting control has changed.
7. Additional refrigerant charge has been changed.(50g/m
➔
25g/m)
MUH-C12SV -
➔
MUH-C12TV -
1. Rated voltage has changed to 230V.
2. Path of heat exchanger has changed.
3. Refrigerant filling capacity has changed.(1.20kg
➔
1.25kg)
4. Capillary tube has changed.(
{
3.0X
{
1.8X250,
➔
{
3.0X
{
1.8X400)
5. High pressure protection temperature has changed.
6. Temperature of defrosting control has changed.
7. Additional refrigerant charge has been changed.(50g/m
➔
25g/m)
E1
E1
E1
E1
E1
E1
E1
E1
E1
Slide switch
H C
Type
The position
of the slide
switch
COOL ONLY
COOL & HEAT
H C