MICROPROCESSOR CONTROL
8
WIRELESS REMOTE CONTROLLER
INDOOR UNIT DISPLAY SECTION
Once the operation mode are set, the same operation mode
can be repeated by simply turning the
OPERATE/STOP(ON/OFF) button ON. Indoor unit receives
the signal with a beep tone.
When the system turns off, 3-minute time delay will operate to
protect system from overload and compressor will not restart
for 3 minutes.
Operation Indicator lamp
The operation indicator located at the right side of the
indoor unit indicates the operation state.
Approx. 2
:
or more
Difference
between target
temperature
and room
temperature
Approx. 2
:
or less
This shows that the
air conditioner is
operating to reach
the target temperature.
Please wait until the
target temperature is
obtained.
This shows that the
room temperature is
approaching the
target temperature.
Operation state
Indication
lighted
not lighted
•The following indication applies regardless of shape of the indicator.
Operation Indicator
COOL mode of
"I FEEL CONTROL"
DRY mode of
"I FEEL CONTROL"
Initial room temperature
25
:
or more
more than 13
:
,
less than 25
:
Mode
8-1. “I FEEL CONTROL” (
) OPERATION
(1) Press OPERATE/STOP(ON/OFF) button on the remote
controller. OPERATION INDICATOR lamp of the indoor
unit turns on with a beep tone.
(2) Select “I FEEL CONTROL”(
) mode with the OPERA-
TION SELECT button.
(3) The operation mode is determined by the room tempera-
ture at start-up of the operation.
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
●
Once the mode is fixed, the mode does not change by
room temperature afterwards.
●
Under the ON-TIMER (
) operation, mode is deter-
mined according to the room temperature at set time the
operation starts.
●
When the system is stopped on the remote controller
and restarted within 2 hours in “I FEEL CONTROL” (
)
mode, the system operates in previous mode automati-
cally regardless of the room temperature.
Restart
COOL mode of
“I FEEL CONTROL”
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
When the system is restarted after 2 hours and more,
the operation mode is determined by the room tempera-
ture at start-up of the operation.
Restart
COOL or DRY mode of
“I FEEL CONTROL”
that determined by
room temperature at
start-up of the opera-
tion.
Operation time chart
Operation time chart
ON/OFF
FAN
TOO
WARM
TOO
COOL
VANE
MODE
ECONO COOL
STOP
START
HR.
MIN.
I FEEL COOL
DRY
PM
CLOCK
AM
RESET CLOCK
FAN
OPERATION SELECT button
FAN SPEED CONTROL button
OFF-TIMER button
HR. button
MIN. button
(TIME SET button)
ON-TIMER button
RESET button
ECONO COOL button
VANE CONTROL button
CLOCK SET button
ON/OFF
TOO
COOL
PM
AM
TOO
WARM
Signal transmitting section
Operation display section
OPERATE /STOP
(ON /OFF)button
TEMPERATURE buttons
MS-09SN -
MS-09SN -
MS-10SN -
MS-10SN -
C2
C1
C2
C1
MS-17SN -
MS-18SN -
MS-24SN -
C1
C1
C1
MS-12SN -
MS-12SN -
MS-15SN -
MS-15SN -
C2
C1
C2
C1
MU-09SN -
MU-09SN -
MU-10SN -
MU-10SN -
C2
C1
C2
C1
MU-17SN -
MU-18SN -
MU-24SN -
C1
C1
C1
MU-12SN -
MU-12SN -
MU-15SN -
MU-15SN -
C2
C1
C2
C1
OB256-1qxp 2.2.8 9:07 AM Page 25
Содержание MS-09SN-C1
Страница 59: ......