51
❈
1 After all units start together, if SW2 is turned OFF, each unit can be individually stopped by each remote controller.
❈
2 After all units stop together, if SW2 is turned OFF, each unit can be individually started by each remote controller.
5. INDIVIDUAL CONTROL BY GROUPING THE REMOTE CON-
TROLLERS
●
Grouping the remote controllers allows individual control and cen-
tralized monitoring of units installed in different places without a
special control board.
●
Remote control cables are extendable up to 500m. When the cable
length exceeds 12m, use the double-insulated two-care cable such
as Belden 9407. Also, the cable thickness must be No. 22 AWG or
above.
●
When gathering the power ON/OFF switches of air conditioners
near the remote controllers, you should also install the power
ON/OFF switch near each unit to prevent electric trouble during
servicing.
4. REMOTE ON-OFF AND INDIVIDUALREMOTE CONTROLS
4-1 Switch function of remote ON-OFF switch
SW1
(Switches between
remote ON and OFF.)
ON
(Start)
OFF
(Stop)
All units start together.
Individual control is not available.
All units stop together.
Individual control is not available.
SW2
(Switches between remote ON-OFF and individual control)
ON
(Remote ON-OFF control)
Each unit can be controlled by each
remote controller.
Remote ON-OFF switch is not available.
OFF
(Individual control)
❈
1
❈
2
Remote
controller cable (2-core)
Remote controller
OC121--2.qxp 24/6/97 2:18 AM Page 51