27
12
OPTIONAL PARTS
1. REFRIGERANT PIPES
28˚C
26˚C
8:00
Normai
operation
8:00
Normai
operation
23:00
Setback
operation
3. TIMER
When using a program timer, a program timer adapter (PAC-825AD)is also needed.
3-1 Program timer specifications
3-2 Feature of program timer
(1) Daily timer function
Daily timer can be set in 30 minute units for up to 24 hours.
Each unit can be set for unit ON, unit OFF, or setback operation.
(2) Setback operation(PAC-SK65PT)
Set back operation is useful for reducing running costs.
e.g.AT a hotel with a 24-hour system
8:00~23:00 Cooling operation with set temperature at 26 ˚C
23:00~8:00 Setback operation with 2 degrees of setback
As shown in the chart on the right, the set temperature rises 2
degrees automatically during the setback operation. When the set-
back operation ends, normal operation will begin.
(3) Weekly timer function
Daily timer function can apply to each day of the week.
Part No.
PAC-05FFS-E
PAC-07FFS-E
PAC-10FFS-E
PAC-15FFS-E
5m
7m
10m
15m
Pipe length
Pipe size OD
Connection method
Liquid:/ø9.52 Gas:/ø15.88
Indoor unit:Flared Outdoor unit:Flared
Note 1.How to connect refrigerant pipes.
Factory supplied optional piping contains refrigerant at above atmospheric pressure. As long as the
connection takes no more than 5 minutes, no air will enter, and there will be no need for air purging.
Remove the blind caps and make the connections within 5 minutes. After the connections for the indoor and
outdoor units are made, open the stop valve on the outdoor unit to allow refrigerant gas to flow.
If piping length exceeds 5m, an additional charge of refrigerant is needed.
Note 2.The following main parts are contained in the optional refrigerant piping kit.
Heat insulating cover, vinyl tapes, nipples, sleeve and flange(for wall hole), connecting cables.
Part No.
Model Name
PAC-SK65PT(with set back function)
Program timer
Part name
Part No.
Program timer
PAC-SK65PT
Exterior dimensions(mm)
120X120X15 (mm)
Installation
Wall mount
Type of clock
Quartz
Clock accuracy
±
50second/month
Display-Time
Liquid crystal display
Liquid crystal display
Liquid crystal display
Program cycle
-Timer
-Week
24 hours
Timer setting unit
30 minutes
No. of set points
48/day
Power rating
5V DC
Set back function
Provided
2. REMOTE CONTROLLER EXTENSION CABLE
When installing the remote controller at a distance from the air conditioner, use the designated extension cable with
connector.
Part No.
PAC-905EC
PAC-906EC
PAC-918EC
PAC-919EC
12m
20m
30m
50m
Length
Содержание Mr.SLIM PED-2.5EJA1.UK
Страница 2: ......
Страница 14: ...12 Figure3 Fan base Sirocco fan Sirocco fan Housing assembly Housing assembly Piece Piece Leg Bush Bush Motor ...
Страница 21: ...19 10 MICROPROCESSOR CONTROL ...
Страница 22: ...20 l ...
Страница 23: ...21 l ...
Страница 24: ...22 l l after ...
Страница 25: ...23 ...
Страница 26: ...24 ...
Страница 27: ...25 11 TROUBLE SHOOTING ...
Страница 28: ...26 ...
Страница 35: ......