9
(OHFWULFDOZRUN
&RQQHFWLQJSURFHGXUHV)LJ
Connect the remote controller cord to the terminal block.
To TB5 on the indoor unit
TB6 (No polarity)
3) 2 remote controllers setting
If 2 remote controllers are connected, set one to “Main” and the other to “Sub”. For
setting procedures, refer to “Function selection of remote controller” in the opera-
tion manual for the indoor unit.
)RUZLUHOHVVUHPRWHFRQWUROOHU
1) Installation area
• Area in which the remote controller is not exposed to direct sunshine.
• Area in which there is no nearby heating source.
• Area in which the remote controller is not exposed to cold (or hot) winds.
• Area in which the remote controller can be operated easily.
• Area in which the remote controller is beyond the reach of children.
,QVWDOODWLRQPHWKRG)LJ
Attach the remote controller holder to the desired location using 2 tapping screws.
Place the lower end of the controller into the holder.
Remote controller
Wall
Display panel
Receiver
• The signal can travel up to approximately 7 meters (in a straight line) within 45
degrees to both right and left of the center line of the receiver.
6HWWLQJ)LJ
Insert batteries.
Press the SET button with something sharp at the end.
MODEL SELECT
blinks and Model No. is lighted.
Press the temp
buttons to set the Model No.
If you mistook the operation, press the ON/OFF
button and operate again
from procedure
.
Press the SET button with something sharp at the end.
MODEL SELECT
and Model No. are lighted for 3 seconds, then turned off.
Indoor
Outdoor
Model No.
PCA
PUH, PUHZ, SUZ
001
PU
033
$VVLJQLQJDUHPRWHFRQWUROOHUWRHDFKXQLW)LJ
Each unit can be operated only by the assigned remote controller.
Make sure each pair of an indoor unit PC board and a remote controller is assigned
to the same pair No.
5) Wireless remote controller pair number setting operation
Press the SET button with something sharp at the end.
Start this operation from the status of remote controller display turned off.
MODEL SELECT
blinks and Model No. is lighted.
Press the
min
button twice continuously. Pair No. “0” blinks.
Press the temp
buttons to set the pair number you want to set.
If you mistook the operation, press the ON/OFF
button and operate again
from procedure
.
Press the SET button with something sharp at the end.
Set pair number is lighted for 3 seconds then turned off.
Pair No. of wireless remote controller
Indoor PC board
0
Initial setting
1
Cut J41
2
Cut J42
3-9
Cut J41, J42
ON/OFF
TEMP
RESET
SET
CLOCK
MODEL SELECT
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
Fig. 6-6
B
TB
Fig. 6-4
Fig. 6-5
A
6
Fig. 6-7
ON/OFF
TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESET
SET
CLOCK
MODEL SELECT