Содержание Mr. Slim MXZ-2A20NA

Страница 1: ...nstallation for indoor unit please refer to the installation manual being attached each indoor unit The installation manual details the suggested installation method Any structural alterations necessary for installation must comply with local building code requirements 1 BEFORE INSTALLATION 2 2 OUTDOOR UNIT INSTALLATION 5 3 FLARING WORKAND PIPE CONNECTION 7 4 PURGING PROCEDURES LEAK TEST AND TEST ...

Страница 2: ...stallation has been completed If refrigerant gas leaks indoors and comes into contact with the flame of a fan heater space heater stove etc harmful substances will be generated Use appropriate tools and piping materials for installation The pressure of R410A is 1 6 times more than R22 Not using appropri ate tools or materials and incomplete installation could cause the pipes to burst or injury Whe...

Страница 3: ...nt exposure to wind it is recommended to install a baffle board on the air outlet side of the outdoor unit wold the following places for installation where air conditioner trouble is liable to occur Where flammable gas could leak Where there is much machine oil Salty places such as the seaside Where sulfide gas is generated such as a hot spring Where there is high frequency or wireless equipment F...

Страница 4: ...oles Unit mm inch PARTS TO BE PROVIDED AT YOUR SITE A Power supply cord 1 B Indoor outdoor unit connecting wire 1 C Extension pipe Refer to 1 4 1 D Wall hole cover 1 E Piping tape 1 Extension drain hose or soft PVC hose 15 mm 19 32 1 F in inner diameter or hard PVC pipe VP16 Little G Refrigeration oil amount H Putty 1 I Pipe fixing band 2 to 7 J Fixing screw for I 2 to 7 K Wall hole sleeve 1 Soft ...

Страница 5: ...he local code Use a ring tongue terminal in order to connect a ground wire to terminal INDOOR UNtTFA I I INDOOR UNITII_I Terminal block Terminal block _ Grounding Grounding ___ _ _ _ii_mina ____ _____ii_mina iill i 2081230VA _ i Disconnect 2081230VA i Disconnect lphaseg0Hz i iswitch lphaseg0Hz_ iswitch Te_ _ o_ 31 _ block 1 Terurr NIl ACk TeUnNII _BOCk _ I L_ OUTDOOR UNIT Ground I Connect wires to...

Страница 6: ...410A for R22 _a6 35 1 4 17 _a9 52 3 8 22 0 to 0 5 _a12 7 1 2 26 0 to 0 02 _a15 88 5 8 29 1 0 to 1 5 0 04 to 0 06 Wing nut type tool for R22 1 5 to 2 0 0 06 to 0 08 2 0 to 2 5 0 08 to 1 0 Tightening torque N m kgf cm 13 7 to 17 7 140 to 180 34 3to41 2 350 to 420 49 0 to 56 4 500 to 575 73 5 to 78 4 750 to 800 ft lb 10 to 13 25 to 30 36 to 42 54 to 58 3 2 PIPE CONNECTION Fasten flare nut with a torq...

Страница 7: ...ge manifold valve for R410A gh Charge hose for R410A Vacuum pump for R41OA Precautions when using the centre va ve A Close Body v_nte ro __S_vice port Char0ehese IX_ L _ _ for R410A When attachinu the control valve to the service Port valve core may de form or loosen if excess pressure is applied This may cause qas leak When attaching the control valve to the service port make sure that the valve ...

Страница 8: ...tive mechanism Once the compressor stops the restart preventive device operates so the compressor will not operate for 3 minutes to protect the air conditioner 4 4 EXPLANATION TO THE USER Using the OPERATING INSTRUCTIONS explain to the user how to use the air conditioner how to use the remote controller how to remove the air fil ters how to remove or put the remote controller in the remote control...

Страница 9: ..._1 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79A039H01 JG79A039H01 cover4 indd 2 5 9 2008 2 23 16 PM ...