Содержание Mr. Slim MSZ-FE09NA

Страница 1: ...he outlet make sure that there is no dust blockage or loose parts both in the outlet and on the plug Verify that the power supply plug is completely in the outlet If there is dust blockage or loose parts on the power supply plug or the outlet it could cause electric shock or fire If loose parts are found on the power supply plug replace it Securely attach the electrical cover to the indoor unit an...

Страница 2: ...nd a baffle board on the air outlet side Avoid the following places for installation where air conditioner trouble is liable to occur Where flammable gas could leak Where there is an excessive amount of machine oil in the air Salty places such as the seaside Where sulfide gas is generated such as a hot spring Where there is high frequency or wireless equipment 1 3 SPECIFICATIONS 1 3 1 POWER SUPPLY...

Страница 3: ...leeve _ ach t eh pipe to I tt F_ lachment strap E l Cut off the Pipe attachment extra length _rap E Attachment screw F 1 9 After the leak test apply insulating mate 1 j_ rial tightly so that there is no gap J J When the piping is to be attached to a wall comprised of tin plate or metal netting use chemically treated wooden piece 25 32 in 20 mm or thicker between the wall and the piping or wrap ins...

Страница 4: ...ck Be careful not to make mis wiring Attach the wire to the terminal block securely so that its core cannot be seen and no external force affects the connecting section of the terminal block 7 Firmly tighten the terminal screws After tightening verify that the wires are tightly fas tened 8 Secure indoor outdoor unit connecting wire A and the ground wire with conduit cover Never fail to hook the cl...

Страница 5: ...nect the refrigerant piping with the extension pipe B 9 Attach the lower part of the indoor unit into the installation plate 1 _ _ain cap Fig 1 Fig 2 _i _ _ Drain hose Fig 3 Fig 5 Fig 4 Rear or bottom piping 1 Place the refrigerant piping and the drain hose together then firmly apply piping tape G from the end 2 Insert the piping and the drain hose into the wall hole sleeve C and attach the up per...

Страница 6: ... cover 3 2 FLARE CONNECTION t Cut the copper pipe as straight as possible with a pipe cutter Fig 1 2 2 Remove all burrs from the cut section of the pipe ensuring that precautions are taken to avoid getting metal shavings into the piping Fig 3 3 Remove flare nuts attached to indoor and outdoor units then put them on pipe 4 Flaring work Fig 4 5 Firmly hold copper pipe in the dimension shown in the t...

Страница 7: ...nt if needed Be sure to charge slowly with liquid refrigerant Otherwise composition of the refrigerant in the system may be changed and affect performance of the air conditioner 9 Tighten cap of service port 10 Conduct a leak test 4 2 TEST RUN 1 Insert power supply plug into the power outlet and or turn on the breaker 2 Press the E O SW once Test run will be performed for _ 30 minutes If the power...

Страница 8: ...low so that refrigerant is not released into the atmosphere 1 Connect the gauge manifold valve to the service port of the stop valve on the gas pipe side of the outdoor unit 2 Fully close the stop valve on the liquid pipe side of the outdoor unit 3 Close the stop valve on the gas pipe side of the outdoor unit almost completely so that it can be easily closed fully when the pressure gauge shows 0 M...