background image

En-3

• OPERATING INSTRUCTIONS •

Air inlet  (back and side)

Piping
Drainage hose

Air outlet

Drain outlet

Signal transmitting section

Distance of signal : 

About 20ft (6 m)

Beep(s) is (are) heard 

from the indoor unit 

when the signal is 

received.

Temperature buttons

 Page 5 

FAN speed control 

button 

 Page 6 

Use the remote controller provided with the unit only.

Do not use other remote controllers.

Outdoor unit

N

AME OF EACH PART

Indoor unit

Remote controller

Appearance of the outdoor unit may differ from some models.

Display section

Operation 

indicator lamp

Remote control 

receiving section

Horizontal 

vane

Vertical 

vane

Air outlet

Fan

Air fi lter

(Catechin air 

fi lter)

Air inlet

Heat exchanger

Front panel

Air cleaning fi lter 

(Anti-Allergy Enzyme Filter)

Indoor unit

Emergency 

operation 

switch 

 Page 5 

Remote controller 
holder

• Install the remote controller 

holder to a place where the 

signal can be received by 

the indoor unit.

Operation display 

section

ON/OFF

(operate/stop) 

button
Operation 

select button 

 Page 5 

ECONO COOL 

button 

 Page 6 

Off-timer button 

 Page 7 

On-timer button 

 Page 7 

VANE 

control button 

 Page 6 

CLOCK button 

 Page 4 

RESET button 

 Page 4 

TIME set buttons

 

 Pages 4, 7 

  Increase time

  Decrease time

Lid

Slide down to open

POWERFUL 

COOL button 

 Page 6 

SG79Y951H01_EN.indd   3

4/9/07   4:19:28 PM

Содержание Mr. Slim MS-A09WA-1

Страница 1: ...IONERS INDOOR UNIT MS A09WA 1 MS A12WA 1 MSY A15NA 1 MSY A17NA 1 English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read this operating in structions before use MANUAL DE INSTRUCCIONES ...

Страница 2: ...hould not be installed relocated or repaired by the user An improperly handled air conditioner may cause fire or electric shock Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burn ing smell stop the air conditioner and disconnect the power plu...

Страница 3: ...n the breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several sea sons perform inspection and maintenance in ad dition to normal cleaning Dirt or dust in the unit may create an unpleasant odor or clog the drain passage and cause water to leak from the indoor unit Consult your deale...

Страница 4: ...Operation indicator lamp Remote control receiving section Horizontal vane Vertical vane Air outlet Fan Air filter Catechin air filter Air inlet Heat exchanger Front panel Air cleaning filter Anti Allergy Enzyme Filter Indoor unit Emergency operation switch Page 5 Remote controller holder Install the remote controller holder to a place where the signal can be received by the indoor unit Operation disp...

Страница 5: ...ontroller batteries PREPARATION BEFORE OPERATION R E S E T C L O C K 1 Remove the front lid 2 Insert AAA alkaline batteries 3 Install the front lid Press RESET and CLOCK gently using a thin stick If the RESET button is not pressed the remote controller may not operate correctly R E S E T C L O C K 1 Press RESET 2 Press CLOCK 4 Press CLOCK again 3 Press the TIME buttons to set the time Each press i...

Страница 6: ...ure The room temperature is approach ing the set temperature About 2 to 4 F 1 to 2 C from set tem perature Lighted Not lighted Emergency operation When the remote controller cannot be used Emergency operation can be activated by pressing the emergency operation switch E O SW on the indoor unit Each time the E O SW is pressed the operation changes in the following order 1 Press to start the operati...

Страница 7: ...tion To change the horizontal airflow direction Move the vertical vane manually before starting operation AUTO Low Med High AUTO 1 2 3 4 SWING ECONO COOL OPERATION Press during COOL mode page 5 to start ECONO COOL operation The unit performs swing operation vertically in various cycle according to the temperature of the unit Set temperature is set 4 F 2 C higher automatically Press again to cancel ...

Страница 8: ...time or blinks Make sure that the current time is set correctly Page 4 2 Press Increase and Decrease to set the time of timer Each press increases or decreases the set time by 10 minutes Press or again to cancel timer Note ON and OFF timers can be used in combination mark indicates the order of timer operations If power failure occurs while ON OFF timer is set see page 5 Auto restart function ...

Страница 9: ...ts Catechin also offers excellent deodorizing characteristics Catechin air filter uses this compound to not only improve air quality but also prevent the spread of bacteria and viruses in the room CLEANING Switch off the power supply or turn off the breaker before cleaning Be careful not to touch the metal parts with your hands Do not use benzine thinner polishing powder or insecticide Use only dil...

Страница 10: ...f the fan starts to rotate it stops soon When the outside temperature is low dur ing cooling operation the fan operates intermittently to maintain sufficient cooling capacity Symptom Explanation Check points Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 4 Is the pola...

Страница 11: ...ONS 1 Set to the highest temperature in manual COOL mode and operate for 3 to 4 hours Page 5 This dries the inside of the unit 2 Press to stop the operation 3 Turn off the breaker and or disconnect the power sup ply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filters Page 8 2 Check that the air inlet and outlet of the indoor and outdoo...

Страница 12: ...4299 14th Avenue Markham Ontario L3R 0J2 Canada SG79Y951H01 ...