3 BASIC FUNCTION
3.8 Regenerative option selection
59
3
3.8
Regenerative option selection
If the generated regenerative power is large and the regenerative capacity of the built-in regenerative resistor of the servo
amplifier is insufficient, use the regenerative option to improve the regenerative capacity and consume the generated
regenerative power. Set [Pr. PA02.0-1 Regenerative option selection] in accordance with the regenerative resistor in use.
Refer to "Regenerative option" in the following manual for the details of the regenerative options.
MR-JET User's Manual (Hardware)
Regenerative option
For the regenerative options, select the Mitsubishi Electric-specified regenerative resistor (MR-RB series).
Precautions
• To prevent a fire from occurring, use servo amplifiers with regenerative options in the specified combinations.
Setting method
Servo parameter
Symbol
Name
Outline
PA02.0-1
**REG
Regenerative option selection
Select a regenerative option to be used.
00: Regenerative option is not used.
• For 100 W and 200 W servo amplifiers, the regenerative resistor is
not used.
• For 0.4 kW to 3 kW servo amplifiers, the built-in regenerative resistor
is used.
02: MR-RB032
03: MR-RB12
05: MR-RB30
06: MR-RB50 (A cooling fan is required.)
0D: MR-RB14
0E: MR-RB34