![Mitsubishi Electric MR-J5D Скачать руководство пользователя страница 136](http://html.mh-extra.com/html/mitsubishi-electric/mr-j5d/mr-j5d_user-manual_1811806136.webp)
134
6 OPTIONS AND PERIPHERAL EQUIPMENT
6.7 Earth-leakage current breaker
6.7
Earth-leakage current breaker
For details on how to select an earth-leakage circuit breaker, refer to "Earth-leakage current breaker" in the following manual.
MR-CV Power Regeneration Converter Unit User's Manual
Servo motor leakage current example (Igm)
Drive unit leakage current example (Iga)
Servo motor output [kW]
Leakage current [mA]
0.05 to 1
0.1
1.2 to 2
0.2
3 to 3.5
0.3
4.2 to 5
0.5
6 to 7
0.7
Drive unit
Leakage current [mA]
MR-J5D1-100_
MR-J5D1-200_
MR-J5D1-350_
0.3
MR-J5D1-500_
MR-J5D1-700_
0.5
MR-J5D2-100_
MR-J5D2-200_
MR-J5D2-350_
0.3
MR-J5D2-500_
MR-J5D2-700_
0.5
MR-J5D3-100_
MR-J5D3-200_
0.3
Содержание MR-J5D