3 SIGNALS AND WIRING
3.5 Signal (device) explanation
61
3
Output device explanation
■
ALM (Malfunction)
If the protective circuit operates and shuts off the base circuit, ALM will turn off.
If an alarm is not occurring, ALM will turn on in 2.5 s to 3.5 s after power-on (or in 3.5 s to 4.0 s for a multi-axis servo amplifier).
■
INP (In-position)
If droop pulses are within the in-position range, INP will turn on. The in-position range can be changed with [Pr. PA10]. When
the servo motor is operated at low speed by increasing the in-position range, INP may remain on.
The device cannot be used in the velocity mode or torque mode.
■
RD (Ready)
When the servo amplifier becomes in the servo-on state, RD switches on.
Variable gain
selection 2
CDPS2
DO-1
CDPS2 (Variable
gain selection 2)
Absolute position
undetermined
ABSV
DO-1
ABSV (Absolute
position
undetermined)
During tough
drive
MTTR
DO-1
Electromagnetic
brake interlock
MBR
DO-1
MBR
(Electromagnetic
brake interlock)
Limiting speed
VLC
DO-1
Zero speed
detection
ZSP
DO-1
Limiting torque
TLC
DO-1
ABS
transmission
data bit 0
ABSB0
DO-1
ABSB0 (ABS
transmission
data bit 0)
ABS
transmission
data bit 1
ABSB1
DO-1
ABSB1 (ABS
transmission
data bit 1)
ABS
transmission
data ready
ABST
DO-1
ABST (ABS
transmission
data ready)
Malfunction/
Warning
ALMWNG
DO-1
AL9F warning
BW9F
DO-1
Device name
Symbol
Model
I/O signal
interface type
Detailed
explanation
G
A
P
S
T