1 SERVO PARAMETER DETAILS
1.4 Extension setting servo parameters group ([Pr. PC_ _ ])
[Pr. PC41_Function selection C-J (*COPJ)]
[Pr. PC41.0_[AL. 090.1 Homing incomplete] detection selection]
Enable or disable [AL. 090.1 Homing incomplete].
This function is enabled in the cyclic synchronous position mode.
When setting this servo parameter to "1" (disabled), set [Pr. PC29.5 [AL. 0E3 Absolute position counter warning] selection] to
"0" (disabled).
0: Enabled
1: Disabled
[Pr. PC41.3_Electromagnetic brake sequence output function selection]
When shifting the PDS state from the Operation enabled state to servo-off, select a state after transition which enables [Pr.
PC02 Electromagnetic brake sequence output]. The state changes to the one selected with this servo parameter after the
time set in [Pr. PC02] has passed.
0: Switched on
1: Switched on/Ready to switch on/Switch on disabled
When [Pr. PC46.2 Protection coordination multiple connections selection] is set to "1" (connect multiple MR-J5D_-_G_ to the
converter unit), setting this servo parameter to "1" triggers [AL. 037 Parameter error].
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A5
Initial value
Setting range
Ver.
0h
Refer to the text
C0