132
1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
[Pr. PF71_Belt failure prediction function selection (BFP)]
[Pr. PF71.0_Belt tension deterioration prediction function selection]
0: Disabled
1: Execute only belt tension estimation
2: Belt tension deterioration prediction function enabled
After the equipment goes into full-scale operation, enable the belt tension deterioration prediction function.
[Pr. PF71.1_Belt tension deterioration prediction friction selection]
Select a static friction setting used for belt tension deterioration prediction.
0: Automatic setting
1: At forward rotation torque
2: At reverse rotation torque
3: Average at forward rotation/reverse rotation torque
When set to "0", the value changes to any of "1" to "3", depending on the operation pattern.
[Pr. PF72_Belt tension on installation (SBT)]
Set a belt tension for when the belt is attached to the equipment. The servo parameter indicates the reference belt tension
threshold used in the belt diagnosis function.
[Pr. PF73_Belt tension when extended (ABT)]
After the equipment is operated, set a belt tension for when the belt stretches or for when the belt is looser than at the time of
the attachment. After the belt has been attached to the equipment, the time taken for the belt to stretch depends on the belt
type. For the time taken for the belt to stretch, refer to the catalog or other documents from the manufacturer.
The belt tension deterioration prediction function is disabled when the setting is: [Pr. PF72 Belt tension on installation] < [Pr.
PF73 Belt tension when extended].
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Initial value
Setting range
Setting method
Ver.
0 [0.1 N]
0 to 1000000
Each axis
A0
Initial value
Setting range
Setting method
Ver.
0 [0.1 N]
0 to 1000000
Each axis
A0
Содержание MR-J5-G Series
Страница 2: ......
Страница 215: ...4 SERVO PARAMETER SETTING METHOD 4 2 Object dictionary 213 4 MEMO ...
Страница 226: ...224 6 NETWORK PARAMETER SETTING METHOD 6 1 Engineering tool MEMO ...
Страница 255: ...9 FUNCTIONAL SAFETY PARAMETER SETTING METHOD 9 1 Engineering tool 253 9 MEMO ...
Страница 259: ......