100
1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
[Pr. PF46_Vibration failure prediction - Standard deviation (VSD)]
Set the vibration level standard deviation during servo motor operation.
This servo parameter is enabled when [Pr. PF34.0 Friction failure prediction warning selection] is set to "2" (enabled (manual
threshold setting)).
When [Pr. PF34.0 Friction failure prediction warning selection] is set to "1" (enabled (automatic threshold setting)), the value
will be calculated automatically from the estimated friction torque at rated speed.
[Pr. PF47_Servo motor total travel distance offset (TMO)]
Set an offset value for machine total travel distance.
After the equipment is replaced, set this servo parameter.
[Pr. PF63_Function selection F-15 (*FOP15)]
[Pr. PF63.0_[AL. 01A.5 Servo motor combination error 3] selection]
Select whether to enable or disable [AL. 01A.5 Servo motor combination error 3] for when a servo motor with a batteryless
absolute position encoder is replaced.
0: Enabled
1: Disabled
With "1" (disabled) selected, connecting a servo motor that had not been connected at the startup of the absolute position
detection system triggers [AL. 025.1 Servo motor encoder absolute position erased] instead of [AL. 01A.5 Servo motor
combination error 3].
Connecting a servo motor other than the ones with a batteryless absolute position encoder triggers [AL. 01A.5].
[Pr. PF63.1_[AL. 01A.6 Servo motor combination error 4] selection]
Select whether to enable or disable [AL. 01A.6 Servo motor combination error 4] for when a servo motor with a batteryless
absolute position encoder is replaced.
0: Enabled
1: Disabled
With "1" (disabled) selected, connecting a servo motor that had not been connected at the startup of the absolute position
detection system triggers [AL. 025.2 Scale measurement encoder - Absolute position erased] instead of [AL. 01A.6 Servo
motor combination error 4].
Connecting a servo motor other than the ones with a batteryless absolute position encoder triggers [AL. 01A.6].
Initial value
Setting range
Setting method
Ver.
0 [0.1 %]
0 to 20000
Each axis
C4
Initial value
Setting range
Setting method
Ver.
0 [10 rev], [m]
0 to 4294967295
Each axis
C4
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
D0
Initial value
Setting range
Ver.
0h
Refer to the text
D0