10 OPTIONS AND PERIPHERAL EQUIPMENT
10.2 Selection example of wires
89
10
10.2
Selection example of wires
• To comply with the IEC/EN/UL/CSA standard for wiring, use the wires described in "MR-CV_ Instructions
and Cautions for Safe Use of AC Servos (IB(NA)-0300228)". To comply with other standards, use wires that
comply with each standard.
• Selection requirements for the wire size are as follows.
Construction requirements: Single wire set in midair
Wiring length: 50 m or less
Selection example of wires for converter unit
The following shows the wires used for wiring. Use the wires given in this section or equivalent wires. The following figure is a
schematic diagram that shows the wires used for wiring.
MR-CV_
L1
L2
L3
L11
L21
(2) Control circuit power supply lead
(1) Main circuit power supply lead
Power supply